Parameter estimation to study the immediate impact of aortic cross-clamping using reduced order models

被引:4
|
作者
Ventre, Jeanne [1 ]
Teresa Politi, M. [2 ,3 ]
Fernandez, Juan M. [2 ,3 ]
Ghigo, Arthur R. [4 ]
Gaudric, Julien [1 ,5 ]
Wray, Sandra A. [6 ]
Lagaert, Jean-Baptiste [7 ]
Armentano, Ricardo [8 ]
Capurro, Claudia [2 ,3 ]
Fullana, Jose Maria [1 ]
Lagree, Pierre-Yves [1 ]
机构
[1] Sorbonne Univ, Inst Jean Le Rond Alembert, CNRS, Paris, France
[2] Univ Buenos Aires, Fac Med, Lab Biomembranas, Dept Ciencias Fisiol, Buenos Aires, DF, Argentina
[3] Univ Buenos Aires, Inst Fisiol Biofis Bernardo Houssay, CONICET, Buenos Aires, DF, Argentina
[4] Univ Toulouse, Inst Mecan Fluides Toulouse IMFT, UPS, INPT, Toulouse, France
[5] Hop Univ Pitie Salpetriere, Serv Chirurg Vasc, Paris, France
[6] Univ Favaloro, Inst Med Traslac Trasplante & Bioingn, CONICET, Buenos Aires, DF, Argentina
[7] Univ Paris Sud, Lab Math Orsay, CNRS, Orsay, France
[8] Univ Republica, Dept Ingn Biol, Montevideo, Uruguay
关键词
0D model; 1D model; clamping; inverse problem; parameter estimation; CARDIAC-OUTPUT MEASUREMENT; PULSE-WAVE PROPAGATION; BLOOD-FLOW SIMULATIONS; QUASI-NEWTON METHODS; MATHEMATICAL-MODEL; ESOPHAGEAL DOPPLER; ARTERIAL; HEMODYNAMICS; PRESSURE; ELEMENT;
D O I
10.1002/cnm.3261
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Aortic cross-clamping is a common strategy during vascular surgery, however, its instantaneous impact on hemodynamics is unknown. We, therefore, developed two numerical models to estimate the immediate impact of aortic clamping on the vascular properties. To assess the validity of the models, we recorded continuous invasive pressure signals during abdominal aneurysm repair surgery, immediately before and after clamping. The first model is a zero-dimensional (0D) three-element Windkessel model, which we coupled to a gradient-based parameter estimation algorithm to identify patient-specific parameters such as vascular resistance and compliance. We found a 10% increase in the total resistance and a 20% decrease in the total compliance after clamping. The second model is a nine-artery network corresponding to an average human body in which we solved the one-dimensional (1D) blood flow equations. With a similar parameter estimation method and using the results from the 0D model, we identified the resistance boundary conditions of the 1D network. Determining the patient-specific total resistance and the distribution of peripheral resistances through the parameter estimation process was sufficient for the 1D model to accurately reproduce the impact of clamping on the pressure waveform. Both models gave an accurate description of the pressure wave and had a high correlation (R-2 > .95) with experimental blood pressure data.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Inverse parameter estimation using compressed sensing and POD-RBF reduced order models
    Rao, Preetham P.
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2024, 422
  • [22] An evaluation of acid-base changes following aortic cross-clamping using transcutaneous carbon dioxide monitoring
    Tobias, J. D.
    Russo, P.
    Russo, J.
    PEDIATRIC CARDIOLOGY, 2006, 27 (05) : 585 - 588
  • [23] Reduced order parameter estimation using quasilinearization and quadratic programming
    Siade, Adam J.
    Putti, Mario
    Yeh, William W-G
    WATER RESOURCES RESEARCH, 2012, 48
  • [24] The Impact of Suprarenal Cross-Clamping on Kidney Function in Patients Undergoing Retroperitoneal Abdominal Aortic Aneurysm Repair following an Enhanced Recovery Protocol
    Traina, Luca
    Acciarri, Pierfilippo
    Phillips, Alice
    Spadaro, Savino
    Zenunaj, Gladiol
    Spataro, Claudio
    Camagni, Alice
    Portinari, Mattia
    Gasbarro, Vincenzo
    ANNALS OF VASCULAR SURGERY, 2021, 71 : 346 - 355
  • [25] Physiologic Responses to Infrarenal Aortic Cross-Clamping during Laparoscopic or Conventional Vascular Surgery in Experimental Animal Model: Comparative Study
    Martin-Cancho, Maria F.
    Crisostomo, Veronica
    Soria, Federico
    Calles, Carmen
    Sanchez-Margallo, Francisco M.
    Diaz-Gueemes, Idoia
    Uson-Gargallo, Jesus
    ANESTHESIOLOGY RESEARCH AND PRACTICE, 2008, 2008
  • [26] SIMPLE METHOD TO STABILIZE THE BLOOD-PRESSURE IN THE AORTIC-ARCH DURING DISTAL CROSS-CLAMPING - AN EXPERIMENTAL-STUDY
    ROBICSEK, F
    VAJTAI, P
    MASTERS, TN
    WILKINSON, HA
    VASCULAR SURGERY, 1985, 19 (06): : 390 - 398
  • [27] Modal parameter estimation for fluid-loaded structures from reduced order models
    Li, Xianhui
    Li, Sheng
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 120 (04): : 1996 - 2003
  • [28] Effect of Aortic Cross-Clamping Time on Development of Postoperative Atrial Fibrillation in Isolated CABG: A Single-Center Prospective Clinical Study
    Dayi, Hatice Isil
    Calik, Eyup Serhat
    Birdal, Oguzhan
    Aydin, Muhammed Enes
    Borulu, Ferhat
    Yildiz, Ziya
    Erkut, Bilgehan
    Unlu, Yahya
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2023, 38 (04)
  • [29] Using reduced-order models to study dynamic legged locomotion: Parameter identification and model validation
    Burden, S. A.
    Revzen, S.
    Moore, T. Y.
    Sastry, S. S.
    Full, R. J.
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2013, 53 : E25 - E25
  • [30] ON-LINE PARAMETER ESTIMATION OF REDUCED-ORDER MODELS FOR BUILDINGS ENERGY DYNAMICS USING THE MODULATING FUNCTION METHOD
    Ionesi, Ana
    Jouffroy, Jerome
    2018 WINTER SIMULATION CONFERENCE (WSC), 2018, : 503 - 514