Sub-second pencil beam dose calculation on GPU for adaptive proton therapy

被引:25
|
作者
da Silva, Joakim [1 ,2 ]
Ansorge, Richard [1 ]
Jena, Rajesh [2 ]
机构
[1] Univ Cambridge, Cavendish Lab, Cambridge CB3 0HE, England
[2] Univ Cambridge, Dept Oncol, Cambridge, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 12期
关键词
proton therapy; dose calculation; GPU; graphics processing unit; pencil beam; adaptive radiotherapy; dose reconstruction; TREATMENT PLANNING SYSTEM; MONTE-CARLO SIMULATIONS; ALGORITHM; RADIOTHERAPY; IMPLEMENTATION;
D O I
10.1088/0031-9155/60/12/4777
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although proton therapy delivered using scanned pencil beams has the potential to produce better dose conformity than conventional radiotherapy, the created dose distributions are more sensitive to anatomical changes and patient motion. Therefore, the introduction of adaptive treatment techniques where the dose can be monitored as it is being delivered is highly desirable. We present a GPU-based dose calculation engine relying on the widely used pencil beam algorithm, developed for on-line dose calculation. The calculation engine was implemented from scratch, with each step of the algorithm parallelized and adapted to run efficiently on the GPU architecture. To ensure fast calculation, it employs several application-specific modifications and simplifications, and a fast scatter-based implementation of the computationally expensive kernel superposition step. The calculation time for a skull base treatment plan using two beam directions was 0.22s on an Nvidia Tesla K40 GPU, whereas a test case of a cubic target in water from the literature took 0.14s to calculate. The accuracy of the patient dose distributions was assessed by calculating the gamma-index with respect to a gold standard Monte Carlo simulation. The passing rates were 99.2% and 96.7%, respectively, for the 3%/3 mm and 2%/2 mm criteria, matching those produced by a clinical treatment planning system.
引用
收藏
页码:4777 / 4795
页数:19
相关论文
共 50 条
  • [21] Fast Monte Carlo Dose Calculation on GPU for Proton Therapy
    Jia, X.
    Schuemann, J.
    Paganetti, H.
    Jiang, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S841 - S841
  • [22] Extended collimator model for pencil-beam dose calculation in proton radiotherapy
    Kanematsu, Nobuyuki
    Akagi, Takashi
    Takatani, Yasuyuki
    Yonai, Shunsuke
    Sakamoto, Hidenobu
    Yamashita, Haruo
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (19): : 4807 - 4817
  • [23] Incorporating partial shining effects in proton pencil-beam dose calculation
    Li, Yupeng
    Zhang, Xiaodong
    Lii, MingFwu
    Sahoo, Narayan
    Zhu, Ron X.
    Gillin, Michael
    Mohan, Radhe
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (03): : 605 - 616
  • [24] Development of a GPU-Based Dose Delivery System for Adaptive Pencil Beam Scanning
    Giordanengo, S.
    Russo, G.
    Marchetto, F.
    Monaco, V.
    Pella, A.
    Varasteh, M.
    Attili, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 246 - 247
  • [25] Validation of a Pencil Beam Model for Collimated Proton Therapy Dose Calculations
    Bennett, L.
    Smith, B.
    Wang, D.
    Flynn, R.
    Hyer, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E167 - E167
  • [26] Monte Carlo Dose Verification of Pencil Beam Scanning Proton Therapy
    Giantsoudi, D.
    Clasie, B.
    Grassberger, C.
    Dowdell, S.
    Depauw, N.
    Madden, T.
    Kooy, H.
    Paganetti, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [27] Characterization and validation of a Monte Carlo code for independent dose calculation in proton therapy treatments with pencil beam scanning
    Fracchiolla, F.
    Lorentini, S.
    Widesott, L.
    Schwarz, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21): : 8601 - 8619
  • [28] Adaptive Planning Workflow in a Pencil Beam Scanning Proton Therapy Center
    Blakey, M.
    Price, S.
    Robison, B.
    Niek, S.
    Moe, S.
    Renegar, J.
    Mark, A.
    Spenser, W.
    MEDICAL PHYSICS, 2015, 42 (06) : 3282 - 3282
  • [29] Experimental evaluation of a spatial resampling technique to improve the accuracy of pencil-beam dose calculation in proton therapy
    Egashira, Yusuke
    Nishio, Teiji
    Matsuura, Taeko
    Kameoka, Satoru
    Uesaka, Mitsuru
    MEDICAL PHYSICS, 2012, 39 (07) : 4104 - 4114
  • [30] Adaptive Spot Placement Method for Pencil Beam Scanning Proton Therapy
    Lin, B.
    Lin, Y.
    McDonald, M.
    Bradley, J.
    Fu, S.
    Gao, H.
    MEDICAL PHYSICS, 2021, 48 (06)