Determination of ultra-trace level plutonium isotopes in soil samples by triple-quadrupole inductively coupled plasma-mass spectrometry with mass-shift mode combined with UTEVA chromatographic separation

被引:27
|
作者
Zhang, Weichao [1 ]
Lin, Jianfeng [1 ]
Fang, Sui [1 ]
Li, Chen [2 ]
Yi, Xiaowei [1 ]
Hou, Xiaolin [3 ,4 ]
Chen, Ning [4 ]
Zhang, Haitao [1 ]
Xu, Yihong [2 ]
Dang, Haijun [1 ]
Wang, Wei [1 ]
Xu, Jiang [1 ]
机构
[1] Northwest Inst Nucl Technol, Xian 710024, Peoples R China
[2] Anhui Normal Univ, Sch Geog & Tourism, Key Lab Earth Surface Proc & Reg Response Yangtze, Wuhu 241002, Peoples R China
[3] Tech Univ Denmark, Dept Environm Engn, Riso Campus, DK-4000 Roskilde, Denmark
[4] Chinese Acad Sci, Xian AMS Ctr, Inst Earth Environm, State Key Lab Loess & Quaternary Geol,Shaanxi Key, Xian 710061, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
ICP-MS/MS; Collision-reaction cell; Mass-shift mode; Plutonium; Soil sample; ENVIRONMENTAL-SAMPLES; ICP-MS; PU ISOTOPES; REACTION CELL; SEQUENTIAL DETERMINATION; SEDIMENT SAMPLES; GLOBAL FALLOUT; URANIUM; RESOLUTION; PU-240;
D O I
10.1016/j.talanta.2021.122652
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Although triple-quadrupole inductively coupled plasma-mass spectrometry (ICP-MS/MS) has become an attractive technique for the measurement of long-lived radionuclides, the abundance sensitivity, isobaric and polyatomic ions interferences seriously restrict the application. The spectral peak tailing and uranium hydrides (UH+, UH2+) from U-238 have a serious influence on the accurate measurement of Pu-239 and Pu-240, especially for the ultra-trace level plutonium isotopes in the higher uranium sample. A new method was developed using ICPMS/MS measurement in mass-shift mode with collision-reaction gas combined with a chemical separation procedure. As O-2 readily converted Pu+ ion to PuO2+, while disassociated the interfering diatomic ions of interfering elements (U, Pb, Hg, Tl, etc.), the interferences from these elements were completely eliminated if plutonium was detected as PuO2+ at the m/z more than 270. By the mass filter in MS/MS mode combined with O-2 as reaction gas the lower peak tailing of U-238(+) (<5 x 10(-12)) was significantly suppressed. By this way, the (UO2H+)-U-238/(UO2+)-U-238 atomic ratio was reduced to 4.82 x 10(9), which is significantly lower than that of other collision-reaction gas modes. Interferences from Pb, Hg and Tl polyatomic ions were also completely eliminated. Thus, accurate measurement of ultra-trace level 239Pu in high uranium sample solutions with the Pu-239/U-238 concentration ratio of 10(-10) was achieved by the mass-shift mode with 0.15 mL/min O-2/He + 12.0 mL/min He as collision-reaction gas, and high elimination efficiency of uranium interferences up to 10(14) can be obtained by combination with the chemical separation using a single UTEVA resin column. The developed method can be applied to accurately determine the fg level Pu-239 in high uranium samples, such as large-size deep seawater, deep soil and sediment, uranium debris of nuclear fuel.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Determination of ultra-trace rare earth elements in chondritic meteorites by inductively coupled plasma mass spectrometry
    Liu, HC
    Liu, Y
    Zhang, ZX
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (10) : 1399 - 1404
  • [32] Determination of Rhenium in Geological Samples by Isotope Dilution-Multicollector-Inductively Coupled Plasma-Mass Spectrometry with Novel Chromatographic Separation
    Huang, Xiaoxiao
    Sun, Yali
    Yue, Yahui
    Zhao, Shouqian
    Long, Xiaoping
    ANALYTICAL LETTERS, 2018, 51 (08) : 1122 - 1146
  • [33] AEROSOL DEPOSITION DIRECT SAMPLE INSERTION FOR ULTRA-TRACE ELEMENTAL ANALYSIS BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    RATTRAY, R
    SALIN, ED
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (10) : 829 - 836
  • [34] Separation of actinides at ultra-trace level from urine matrix using extraction chromatography-inductively coupled plasma mass spectrometry
    Hang, W
    Zhu, LW
    Zhong, WW
    Mahan, C
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (08) : 966 - 972
  • [35] Determination and Evaluation of Ultra-trace Levels of Titanium in Bearing Steel by Inductively Coupled Plasma Tandem Mass Spectrometry
    Wang, Dan
    Li, Hui
    Guo, Lili
    Guo, Hongjie
    Li, Xiaoxu
    Li, Sisi
    Zhang, Zhongyuan
    ATOMIC SPECTROSCOPY, 2024, 45 (06)
  • [36] Analytical application of collision/reaction cell inductively coupled plasma mass spectrometry for the determination of ultra-trace elements
    Cho, Sung-Eel
    Ji, Sang-Un
    Kim, Yong-Ha
    Min, Young-Keun
    Kim, Young-Sang
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2006, 19 (06): : 473 - 481
  • [37] Determination of ultra-trace elements in snow samples by inductively coupled plasma source sector field mass spectrometry using ultrasonic nebulization
    Bensimon, M
    Bourquin, J
    Parriaux, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (06) : 731 - 734
  • [40] Determination of ultra-trace rare earth elements in olivine by laser ablation-sector field-inductively coupled plasma-mass spectrometry
    Chen, Hao
    Tang, Ming
    Wu, Shitou
    Liu, Xuanyu