Dynamics of the aortic annulus in 4D CT angiography for transcatheter aortic valve implantation patients

被引:13
|
作者
Elattar, Mustafa A. [1 ]
Vink, Leon W. [1 ]
van Mourik, Martijn S. [2 ]
Baan, Jan, Jr. [2 ]
van Bavel, Ed T. [1 ]
Planken, R. Nils [3 ]
Marquering, Henk A. [1 ,3 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Biomed Engn & Phys, Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Heart Ctr, Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Radiol, Amsterdam, Netherlands
来源
PLOS ONE | 2017年 / 12卷 / 09期
关键词
MULTIDETECTOR COMPUTED-TOMOGRAPHY; ROOT; CALCIFICATION; DIAMETER; SYSTOLE; REGURGITATION; SEGMENTATION; DIMENSIONS; STIFFNESS; STENOSIS;
D O I
10.1371/journal.pone.0184133
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Transcatheter aortic valve implantation (TAVI) is a well-established treatment for patients with severe aortic valve stenosis. This procedure requires pre-operative planning by assessment of aortic dimensions on CT Angiography (CTA). It is well-known that the aortic root dimensions vary over the heart cycle. However, sizing is commonly performed at either mid-systole or end-diastole only, which has resulted in an inadequate understanding of its full dynamic behavior. Study goal We studied the variation in annulus measurements during the cardiac cycle and determined if this variation is dependent on the amount of calcification at the annulus. Methods We measured and compared aortic root annular dimensions and calcium volume in CTA acquisitions at 10 cardiac cycle phases in 51 aortic stenosis patients. Sub-group analysis was performed based on the volume of calcium by splitting the population into mildly and severely calcified valves subgroups. Results For most annulus measurements, the largest differences were found between 10% and 70 to 80% cardiac cycle phases. Mean difference (+/- standard deviation) in annular minimum diameter, maximum diameter, area, and aspect ratio between mid-systole and end-diastole phases were 1.0 +/- 0.29 mm (p = 0.065), 0.30 +/- 0.24 mm (p = 0.7), 24.1 +/- 7.6 mm(2) (p < 0.001), and 0.041 +/- 0.012 (p = 0.039) respectively. Calcium volume measurements varied strongly during the cardiac cycle. The dynamic annulus area was behaving differently between mildly and severely calcified subgroups (p = 0.02). Furthermore, patients with severe aortic calcification were associated with larger annulus diameters. Conclusion There is a significant variation of annulus area and calcium volume measurement during the cardiac cycle. In our measurements, only the dynamic variation of the annulus area is dependent on the severity of the aortic calcification. For TAVI candidates, the annulus area is significantly larger in mid-systole compared to end-diastole.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Analysis of Mitral Valve Motion in 4D Transesophageal Echocardiography for Transcatheter Aortic Valve Implantation
    Weber, Frank M.
    Stehle, Thomas
    Waechter-Stehle, Irina
    Goetz, Michael
    Peters, Jochen
    Mollus, Sabine
    Balzer, Jan
    Kelm, Malte
    Weese, Juergen
    STATISTICAL ATLASES AND COMPUTATIONAL MODELS OF THE HEART: IMAGING AND MODELLING CHALLENGES, 2015, 8896 : 168 - 176
  • [22] Systolic and diastolic parameters of the aortic annulus in patients scheduled for transcatheter aortic valve implantation (TAVI)
    Schuhbaeck, A.
    Leipsic, J.
    Min, J. K.
    Achenbach, S.
    EUROPEAN HEART JOURNAL, 2012, 33 : 89 - 89
  • [23] Transcatheter aortic valve implantation with the Portico and Evolut R bioprostheses in patients with elliptic aortic annulus
    Gorla, Riccardo
    De Marco, Federico
    Morganti, Simone
    Finotello, Alice
    Brambilla, Nedy
    Testa, Luca
    Agnifili, Mauro Luca
    Tusa, Maurizio
    Auricchio, Ferdinando
    Bedogni, Francesco
    EUROINTERVENTION, 2020, 15 (18) : E1588 - +
  • [24] Multimodal Assessment of the Aortic Annulus Diameter Implications for Transcatheter Aortic Valve Implantation
    Messika-Zeitoun, David
    Serfaty, Jean-Michel
    Brochet, Eric
    Ducrocq, Gregory
    Lepage, Laurent
    Detaint, Delphine
    Hyafil, Fabien
    Himbert, Dominique
    Pasi, Nicoletta
    Laissy, Jean-Pierre
    Iung, Bernard
    Vahanian, Alec
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (03) : 186 - 194
  • [25] Aortic annulus rupture during transcatheter aortic valve implantation: safe aortic root replacement
    Eker, Armand
    Sozzi, Fabiola B.
    Civaia, Filippo
    Bourlon, Francois
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (05) : 1205 - 1205
  • [26] TRANSCATHETER AORTIC VALVE IMPLANTATION THE ANNULUS SIZE DOES IT MATTER?
    Saeed, E.
    Almuntaser, I
    Riaz, A.
    Teehan, S.
    Murphy, R.
    Mulvihill, N.
    Foley, B.
    Crean, P.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2010, 179 : S397 - S398
  • [27] Successful Management of Annulus Rupture in Transcatheter Aortic Valve Implantation
    Hayashida, Kentaro
    Bouvier, Erik
    Lefevre, Thierry
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (01) : 90 - 91
  • [28] Atypical Annulus Rupture after Transcatheter Aortic Valve Implantation
    Miura, Mizuki
    Shirai, Shinichi
    Hayashi, Masaomi
    Jinnouchi, Hiroyuki
    Isotani, Akihiro
    Kakumoto, Shinichi
    Arai, Yoshio
    Ando, Kenji
    KOREAN CIRCULATION JOURNAL, 2018, 48 (04) : 332 - 333
  • [29] Numerous patients fail the aortic annulus criteria in transcatheter aortic valve implantation - comparison of current devices
    John, D.
    Hausen, S.
    Latsios, G.
    Yuecel, S.
    Eberle, H. -C.
    Farazandeh, M.
    Gerckens, U.
    Grube, E.
    Naber, C. K.
    Bruder, O.
    EUROPEAN HEART JOURNAL, 2011, 32 : 904 - 904
  • [30] Outcomes of Transcatheter Aortic Valve Replacement in Patients With Small Aortic Annulus
    Bashir, Hanad
    Hasan, Saad
    Caldwell, Austin
    Kereiakes, Dean
    Seshiah, Puvi
    Choo, Joseph
    Answini, Geoffrey
    Seshiah, Meghna
    Schmidt, Christan
    Garcia, Santiago
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B76 - B76