Ultrahigh Accurate 3-D Profilometer

被引:43
|
作者
Tsutsumi, H [1 ]
Yoshizumi, K [1 ]
Takeuchi, H [1 ]
机构
[1] Matsushita Elect Ind Co Ltd, Kadoma, Osaka 571, Japan
关键词
ultrahigh accurate 3-D profilometer; atomic force probe; 3-D measurement; aspeheric lens; lens for optical disc; blu-ray disc; free form; user-specific design formulae;
D O I
10.1117/12.573774
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have developed an Ultrahigh-Accurate 3-D Profilometer (UA3P)[1], which, using a new, in-house-developed atomic force probe, has an accuracy of 10 nm. It is capable of measuring corners as small as 2 micro meter in radius and can cover an area up to 400 x 400 x 90 (mm), providing a powerful boost to nano-level processing. A commercial product was introduced in 1994. Examples of the key components made possible by this technology include aspherical lenses (used for a Blu-ray Disc device, a next- generation DVD, digital cameras, cellular phones, optical corrimunications), free form lenses (used for frennel lens common to CD and DVD, laser printer lens, multi focus glass lens, cubic phase plate to extend depth of focus), gigabit semiconductor wafers, hard discs, air conditioner scroll vanes, DVC cylinders. The premiere ultra high-precision three-dimensional profilometer delivers superb performance using a variety of micro-measurements for a wide range of applications.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 50 条
  • [41] Fast and Accurate 3-D Registration of HR-pQCT Images
    Shi, Lin
    Wang, Defeng
    Hung, Vivian W. Y.
    Yeung, Benson H. Y.
    Griffith, James F.
    Chu, Winnie C. W.
    Heng, Pheng Ann
    Cheng, Jack C. Y.
    Qin, Ling
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (05): : 1291 - 1297
  • [42] Accurate 3-D reconstruction of sands from UAV image sequence
    Matsunaga, Ryotaro
    Hashimoto, Mizuki
    Kanazawa, Yasushi
    Sonoda, Jun
    2016 INTERNATIONAL CONFERENCE ON ADVANCED INFORMATICS - CONCEPTS, THEORY AND APPLICATION (ICAICTA), 2016,
  • [43] An accurate and efficient 3-D micromagnetic simulation of metal evaporated tape
    Jones, M
    Miles, JJ
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1997, 171 (1-2) : 190 - 208
  • [44] Local position measurement system for fast and accurate 3-D monitoring
    Fischer, A
    Pracherstorfer, G
    Stelzer, A
    Söser, A
    NONDESTRUCTIVE DETECTION AND MEASUREMENT FOR HOMELAND SECURITY, 2003, 5048 : 128 - 135
  • [45] Accurate 3-D Capacitance Extractions for Advanced Nanometer CMOS Nodes
    Chang, Keh-Jeng
    Lee, Shih-Hao
    Lee, Kuo-Fu
    Yuh, Ping-Hung
    Yu, Ho-Che
    Huang, Wen-Cheng
    Chang, Victor C. Y.
    2015 International symposium on VLSI Design, Automation and Test (VLSI-DAT), 2015,
  • [46] An accurate solver for 3-D suspended sediment dispersion in tidal flow
    Stansby, PK
    ENVIRONMENTAL AND COASTAL HYDRAULICS: PROTECTING THE AQUATIC HABITAT, PROCEEDINGS OF THEME B, VOLS 1 & 2, 1997, 27 : 1280 - 1285
  • [47] Fast and accurate 3-D spine MRI segmentation using FastCleverSeg
    Ramos, Jonathan S.
    Cazzolato, Mirela T.
    Linares, Oscar C.
    Maciel, Jamilly G.
    Menezes-Reis, Rafael
    Azevedo-Marques, Paulo M.
    Nogueira-Barbosa, Marcello H.
    Traina Junior, Caetano
    Traina, Agma J. M.
    MAGNETIC RESONANCE IMAGING, 2024, 109 : 134 - 146
  • [48] Accurate analysis and modeling of laminated multalayered 3-D optical waveguides
    Massaro, A
    Pierantoni, L
    Rozzi, T
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 2004, 40 (10) : 1478 - 1489
  • [49] An accurate thin-wire model for 3-D TLM simulations
    Sewell, P
    Choong, YK
    Christopoulos, C
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2003, 45 (02) : 207 - 217
  • [50] It is 3-D imaging - No more imagining the era of 3-D CT urogram, 3-D angiogram, 3-D urethrogram
    Yachia, D
    Rub, R
    Jolkowski, E
    Karatas, B
    Erlich, N
    Soimu, U
    Bartal, G
    JOURNAL OF UROLOGY, 2004, 171 (04): : 510 - 510