Data Acquisition and Analysis at the X-ray Computed Tomography Beamline of SESAME

被引:1
|
作者
Iori, Gianluca [1 ]
Matalgah, Salman [1 ]
Chrysostomou, Charalambos [2 ]
Al-Dalleh, Abdalla [1 ]
Alzu'bi, Mustafa [1 ]
机构
[1] SESAME Synchrotron Light Expt Sci & Applicat Midd, Allan, Jordan
[2] Cyprus Inst, Computat Based Sci & Technol Res Ctr, Nicosia, Cyprus
关键词
Computed tomography; X-rays; Imaging; Synchrotron radiation; Data acquisition; Data management; SYNCHROTRON; RECONSTRUCTION; 3D;
D O I
10.1109/JEEIT53412.2021.9634151
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The European Horizon 2020 project BEAmline for Tomography at SESAME (BEATS) aims to design, procure, construct and commission a beamline for hard X-ray full-field tomography at the SESAME synchrotron in Jordan. The beamline will become operative in summer 2022 as the first synchrotron tomography station in the region. Experiments at BEATS will generate large amounts of raw data and require a high-end computational infrastructure to acquire, store, process and manage the collected information. In this paper, we present the design of a pipeline for the acquisition and storage of tomographic scans capable of reaching the required performance. Hardware and software solutions currently under commissioning for image acquisition, tomographic reconstruction and quantitative analysis of 3D data-sets are also described. The BEATS beamline will enable a large variety of applications of X-ray tomography to the user community of SESAME.
引用
收藏
页码:134 / 139
页数:6
相关论文
共 50 条
  • [41] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [42] Reduced acquisition time for L-shell x-ray fluorescence computed tomography using polycapillary x-ray optics
    Vernekohl, Don
    Ahmad, Moiz
    Dai, Xianjin
    Zhao, Wei
    Cheng, Kai
    Xing, Lei
    MEDICAL PHYSICS, 2019, 46 (12) : 5696 - 5702
  • [43] A numismatic study of Roman coins through X-ray fluorescence and X-ray computed μ-tomography analysis
    Smeriglio, Andrea
    Filosa, Raffaele
    Crocco, Maria Caterina
    Formoso, Vincenzo
    Barberi, Riccardo Cristoforo
    Solano, Andrea
    Cerzoso, Maria
    Polosa, Annalisa
    Cerrone, Valerio
    Agostino, Raffaele Giuseppe
    ACTA IMEKO, 2023, 12 (04):
  • [44] Geometric deep learning for enhanced quantitative analysis of microstructures in X-ray computed tomography data
    Lapenna, M.
    Tsamos, A.
    Faglioni, F.
    Fioresi, R.
    Zanchetta, F.
    Bruno, G.
    DISCOVER APPLIED SCIENCES, 2024, 6 (06)
  • [45] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [46] STATISTICAL ASPECTS OF COMPUTED X-RAY TOMOGRAPHY
    CHESLER, DA
    PELC, NJ
    RIEDERER, SJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 130 - 131
  • [47] X-ray computed tomography of ultralightweight metals
    Winter, JM
    Green, RE
    Waters, AM
    Green, WH
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 1999, 11 (04) : 199 - 211
  • [48] X-ray computed tomography for medical imaging
    Hiriyannaiah, HP
    IEEE SIGNAL PROCESSING MAGAZINE, 1997, 14 (02) : 42 - 59
  • [49] Contemporary developments in computed X-ray tomography
    Seibert, JA
    RADIOLOGY, 1998, 209P : 207 - 208
  • [50] Microscopic x-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Zhang, Kun
    Li, Changqing
    MULTIMODAL BIOMEDICAL IMAGING X, 2015, 9316