Dissolution and nanoparticle generation behavior of Be-associated materials in synthetic lung fluid using inductively coupled plasma mass spectroscopy and flow field-flow fractionation

被引:9
|
作者
Huang, Wenjie [1 ,2 ]
Fernandez, Diego [1 ]
Rudd, Abigail [1 ]
Johnson, William P. [1 ]
Deubner, David [3 ]
Sabey, Philip [3 ]
Storrs, Jason [4 ]
Larsen, Rod [4 ]
机构
[1] Univ Utah, Dept Geol & Geophys, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Chem Engn, Salt Lake City, UT 84112 USA
[3] Brush Wellman Inc, Mayfield Hts, OH 44124 USA
[4] Rocky Mt Ctr Occupat Hlth & Safety, Salt Lake City, UT 84112 USA
基金
美国国家科学基金会;
关键词
Beryllium; Toxicity; Field flow fractionation; Nanoparticle; Particle; Dissolution; BERYLLIUM SENSITIZATION; SIZE DISTRIBUTIONS; DISEASE; SPECTROMETRY; PARTICLES; COLLOIDS; ULTRAFILTRATION; TRANSMISSION; OPTIMIZATION; PARTICULATE;
D O I
10.1016/j.chroma.2010.11.070
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Various Be-containing micro-particle suspensions were equilibrated with simulated lung fluid (SLF) to examine their dissolution behavior as well as the potential generation of nanoparticles. The motivation for this study was to explore the relationship between dissolution/particle generation behaviors of Be-containing materials relevant to Be-ore processing, and their epidemiologically indicated inhalation toxicities. Limited data suggest that BeO is associated with higher rates of beryllium sensitization (BS) and chronic beryllium disease (CBD) relative to the other five relevant materials studied: bertrandite-containing ore, beryl-containing ore, frit (a processing intermediate), Be(OH)(2) (a processing intermediate), and silica (control). These materials were equilibrated with SLF at two pH values (4.5 and 7.2) to reflect inter- and intra-cellular environments in lung tissue. Concentrations of Be, Al, and Si in SLF increased linearly during the first 20 days of equilibration, and then rose slowly, or in some cases reached a maximum, and subsequently decreased. Relative to the other materials, BeO produced relatively low Be concentration in solution at pH 7.2; and relatively high Be concentration in solution at pH 4.5 during the first 20 days of equilibration. For both pH values, however, the Be concentration in SLF normalized to Be content of the material was lowest for BeO, demonstrating that BeO was distinct among the four other Be-containing materials in terms of its persistence as a source of Be to the SLF solution. Following 149 days of equilibration, the SLF solutions were fractionated using flow-field flow fractionation (FIFFF) with detection via ICP-MS. For all materials, nanoparticles (which were formed during equilibration) were dominantly distributed in the 10-100 nm size range. Notably, Be produced the least nanoparticle-associated Be mass (other than silica) at both pH values. Furthermore. Be() produced the highest Be concentrations in the size range corresponding to < 3 kDa (determined via centrifugal ultrafiltration), indicating that in addition to persistence, the BeO produced the highest concentrations of truly dissolved (potentially ionic) Be relative to the other materials. Mass balance analysis showed reasonable sample recoveries during FFF fractionation (50-100%), whereas recoveries during ICP-MS (relative to acidified standards) were much lower (5-10%), likely due to inefficiencies in nebulizing and ionizing the nanoparticles. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:4149 / 4159
页数:11
相关论文
共 50 条
  • [21] Sulfur-free Surfactant for Carbide Nanoparticle Characterization in Steel Using Asymmetric Flow Field-Flow Fractionation Hyphenated Inductively Coupled Plasma-Mass Spectrometry
    Daisuke Itabashi
    Kazumi Mizukami
    Shunsuke Taniguchi
    Masayuki Nishifuji
    Hidehiro Kamiya
    Analytical Sciences, 2019, 35 : 995 - 1001
  • [22] Sulfur-free Surfactant for Carbide Nanoparticle Characterization in Steel Using Asymmetric Flow Field-Flow Fractionation Hyphenated Inductively Coupled Plasma-Mass Spectrometry
    Itabashi, Daisuke
    Mizukami, Kazumi
    Taniguchi, Shunsuke
    Nishifuji, Masayuki
    Kamiya, Hidehiro
    ANALYTICAL SCIENCES, 2019, 35 (09) : 995 - 1001
  • [23] Size determination and quantification of engineered cerium oxide nanoparticles by flow field-flow fractionation coupled to inductively coupled plasma mass spectrometry
    Sanchez-Garcia, L.
    Bolea, E.
    Laborda, F.
    Cubel, C.
    Ferrer, P.
    Gianolio, D.
    da Silva, I.
    Castillo, J. R.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1438 : 205 - 215
  • [24] Investigation of silver nanoparticles and plasma protein association using flow field-flow fractionation coupled with inductively coupled plasma mass spectrometry (FlFFF-ICP-MS)
    Wimuktiwan, Panida
    Shiowatana, Juwadee
    Siripinyanond, Atitaya
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (01) : 245 - 253
  • [25] Assessment of metal-extracellular polymeric substances interactions by asymmetrical flow field-flow fractionation coupled to inductively coupled plasma mass spectrometry
    Alasonati, Enrica
    Dubascoux, Stephane
    Lespes, Gaetane
    Slaveykova, Vera I.
    ENVIRONMENTAL CHEMISTRY, 2010, 7 (02) : 215 - 223
  • [26] Analysis of complex particle mixtures by asymmetrical flow field-flow fractionation coupled to inductively coupled plasma time-of-flight mass spectrometry
    Meili-Borovinskaya, Olga
    Meier, Florian
    Drexel, Roland
    Baalousha, Mohammed
    Flamigni, Luca
    Hegetschweiler, Andreas
    Kraus, Tobias
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1641
  • [27] Analysis of pH Dependent Uranium(VI) Sorption to Nanoparticulate Hematite by Flow Field-Flow Fractionation - Inductively Coupled Plasma Mass Spectrometry
    Lesher, Emily K.
    Ranville, James F.
    Honeyman, Bruce D.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (14) : 5403 - 5409
  • [28] Use of flow field-flow fractionation and single particle inductively coupled plasma mass spectrometry for size determination of selenium nanoparticles in a mixture
    Maknun, Luluil
    Sumranjit, Jitapa
    Siripinyanond, Atitaya
    RSC ADVANCES, 2020, 10 (11) : 6423 - 6435
  • [29] Matrix removal before inductively coupled plasma spectrometric detection: another capability of flow field-flow fractionation
    Sangsawong, Supharart
    Shiowatana, Juwadee
    Siripinyanond, Atitaya
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) : 1336 - 1339
  • [30] Development of sedimentation field-flow fractionation-inductively coupled plasma mass-spectrometry for the characterization of environmental colloids
    Ranville, JF
    Chittleborough, DJ
    Shanks, F
    Morrison, RJS
    Harris, T
    Doss, F
    Beckett, R
    ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) : 315 - 329