Angiogram, Fundus, and Oxygen Saturation Optic Nerve Head Image Fusion

被引:0
|
作者
Cao, Hua [1 ]
Khoobehi, Bahram [2 ]
机构
[1] Robot Res Lab, 298 Coates Hall, Baton Rouge, LA 70803 USA
[2] Louisiana State Univ, Hlth Sci Ctr, Opt Phys Lab, New Orleans, LA 70112 USA
关键词
Image Fusion; Optic Nerve Head Imaging; Control Point Detection; Mutual-Pixel-Count;
D O I
10.1117/12.809537
中图分类号
TH742 [显微镜];
学科分类号
摘要
A novel multi-modality optic nerve head image fusion approach has been successfully designed. The new approach has been applied on three ophthalmologic modalities: angiogram, fundus, and oxygen saturation retinal optic nerve head images. It has achieved an excellent result by giving the visualization of fundus or oxygen saturation images with a complete angiogram overlay. During this study, two contributions have been made in terms of novelty, efficiency, and accuracy. The first contribution is the automated control point detection algorithm for multi-sensor images. The new method employs retina vasculature and bifurcation features by identifying the initial good-guess of control points using the Adaptive Exploratory Algorithm. The second contribution is the heuristic optimization fusion algorithm. In order to maximize the objective function (Mutual-Pixel-Count), the iteration algorithm adjusts the initial guess of the control points at the sub-pixel level. A refinement of the parameter set is obtained at the end of each loop, and finally an optimal fused image is generated at the end of the iteration. It is the first time that Mutual-Pixel-Count concept has been introduced into biomedical image fusion area. By locking the images in one place, the fused image allows ophthalmologists to match the same eye over time and get a sense of disease progress and pinpoint surgical tools. The new algorithm can be easily expanded to human or animals' 3D eye, brain, or body image registration and fusion.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Automatic localization of optic nerve head in the fundus images based on cross-network
    School of Electronics and Information Engineering, Beijing Jiaotong University, Beijing 100044, China
    不详
    Dianzi Yu Xinxi Xuebao, 2009, 5 (1170-1174):
  • [32] Effect of Two Different Preprocessing Steps in Detection of Optic Nerve Head in Fundus Images
    Tavakoli, Meysam
    Nazar, Mahdieh
    Mehdizadeh, Alireza
    MEDICAL IMAGING 2017: COMPUTER-AIDED DIAGNOSIS, 2017, 10134
  • [33] Detection of the Optic Nerve Head in Fundus Images of the Retina Using the Hough Transform for Circles
    Xiaolu Zhu
    Rangaraj M. Rangayyan
    Anna L. Ells
    Journal of Digital Imaging, 2010, 23 : 332 - 341
  • [34] Optic nerve head assessment in Light-field fundus images - A case study
    Dietzel, Alexander
    Schramm, Stefan
    Blum, Maren-Christina
    Link, Dietmar
    Klee, Sascha
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [35] Effect of isovolumic hemodilution on oxygen delivery to the optic nerve head
    Chamot, SR
    Petrig, BL
    Pournaras, CJ
    Riva, CE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2002, 219 (04) : 292 - 295
  • [36] Detection of the Optic Nerve Head in Fundus Images of the Retina Using the Hough Transform for Circles
    Zhu, Xiaolu
    Rangayyan, Rangaraj M.
    Ells, Anna L.
    JOURNAL OF DIGITAL IMAGING, 2010, 23 (03) : 332 - 341
  • [37] THE OXYGEN DISTRIBUTION IN THE PRELAMINAR OPTIC-NERVE HEAD OF THE CAT
    AHMED, J
    LINSENMEIER, RA
    DUNN, R
    EXPERIMENTAL EYE RESEARCH, 1994, 59 (04) : 457 - 465
  • [38] Sensitivity and specificity of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen and optic disc oedema
    Gili, Pablo
    Flores-Rodriguez, Patricia
    Yangueela, Julio
    Orduna-Azcona, Javier
    Dolores Martin-Rios, Maria
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (03) : 923 - 928
  • [39] Cost-effective instrumentation for quantitative depth measurement of optic nerve head using stereo fundus image pair and image cross correlation techniques
    Vieira de Carvalho, Luis Alberto
    Carvalho, Valeria
    OPHTHALMIC TECHNOLOGIES XXIV, 2014, 8930
  • [40] Determination of oxygen saturation of the optic nerve head and overlying artery and vein using a snapshot multi-spectral imaging system
    Khoobehi, Bahram
    Eaton, Alexander
    Wafapoor, Hussein
    Fournier, Paul
    Firn, Kim
    Peters, Matt
    Rodebeck, Ellie
    Templet, Brian
    OPTICAL DIAGNOSTICS AND SENSING XII: TOWARD POINT-OF-CARE DIAGNOSTICS AND DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE IV, 2012, 8229