Influence of Rogowski Coil Shielding to Measurement Results

被引:0
|
作者
Hlavacek, Jan [1 ]
Prochazka, Radek [1 ]
Knenicky, Martin [1 ]
Draxler, Karel [2 ]
Styblikova, Renata [3 ]
机构
[1] Czech Tech Univ, Fac Elect Engn, Dept Elect Power Engn, Prague, Czech Republic
[2] Czech Tech Univ, Fac Elect Engn, Dept Measurement, Prague, Czech Republic
[3] Czech Metrol Inst, Dept Electromagnet Quantit, Prague, Czech Republic
关键词
Rogowski coil; coil design; coil shielding; cross wounded winding; impulse current measurement; CALIBRATION;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Rogowski coils (RCs) are usually used for high current measurements from low frequency up to high frequency of a current waveform. These precise and sensitive measurements are very susceptible to interference. A metallic shielding was often used as one of possible solutions. Influences and efficiency of RC shielding to measurement are investigated in the paper. Measurements were carried out for two construction types of RCs. Firstly, usual construction of a RC with uniform winding at non-ferromagnetic toroidal rectangular core. The second RC was constructed with the same core shape, but with an atypical cross wounded winding. Both these constructions are described. These RCs were compared by measurements with and without the shielding. Mathematical model of a RC was built to simulate frequency dependence of the RC constant. Mathematical simulations were validated by measurements of frequency characteristics.
引用
收藏
页码:383 / 387
页数:5
相关论文
共 50 条
  • [31] Measurement technology for pulsed high current of PFN using Rogowski coil
    Zhong, He-Qing
    Zhang, Hua
    Dai, Ling
    Lin, Fu-Chang
    Zou, Yun-Ping
    He, Jun-Jia
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (07): : 84 - 87
  • [32] Rogowski coil: Exceptional current measurement tool for almost any application
    Dupraz, J. P.
    Fanget, Alain
    Grieshaber, Wolfgang
    Montillet, G. F.
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 3768 - 3775
  • [33] An Optically-Interrogated Rogowski Coil for Passive, Multiplexable Current Measurement
    Orr, Philip
    Niewczas, Pawel
    Booth, Campbell
    Fusiek, Grzegorz
    Dysko, Adam
    Kawano, Fumio
    Nishida, Tomonori
    Beaumont, Phil
    IEEE SENSORS JOURNAL, 2013, 13 (06) : 2053 - 2054
  • [34] Calculation of measurement error caused by thermal expansion effect on Rogowski coil
    Hebei Normal University of Science and Technology, Qinhuangdao 066004, China
    不详
    Gaodianya Jishu, 2006, 11 (15-17):
  • [35] Measurement of pulsed heavy current in rail launcher using Rogowski coil
    Zhang, CW
    Li, ZY
    Hu, JL
    Yang, JH
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 2800 - 2803
  • [36] Current Measurement Technology Based on Rogowski Coil Low Voltage Apparatus
    Lang Fu-cheng
    Zhang Hong-kui
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 5895 - 5898
  • [37] Analysis of Influencing Factors on Current Measurement Accuracy of PCB Rogowski Coil
    Wang, Jianhao
    Li, Shihui
    Yu, Xujiang
    Zhou, Run
    Zhu, Zhiting
    Chen, Wei
    IEEE SENSORS JOURNAL, 2025, 25 (06) : 9531 - 9539
  • [38] Determination of Rogowski coil constant
    Draxler, Karel
    Styblikova, Renata
    2006 INTERNATIONAL CONFERENCE ON APPLIED ELECTRONICS, 2006, : 241 - +
  • [39] Magnetic Shielding of Rogowski Coils
    Draxler, Karel
    Styblikova, Renata
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (05) : 1207 - 1213
  • [40] Magnetic Shielding of Rogowski Coils
    Draxler, Karel
    Styblikova, Renata
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 1467 - 1471