Tailoring CT Dose to Patient Size: Implementation of the Updated 2017 ACR Size-specific Diagnostic Reference Levels

被引:12
|
作者
Klosterkemper, Yan [1 ]
Appel, Elisabeth [1 ]
Thomas, Christoph [1 ]
Bethge, Oliver T. [1 ]
Aissa, Joel [1 ]
Kroepil, Patric [1 ]
Antoch, Gerald [1 ]
Boos, Johannes [1 ]
机构
[1] Univ Dusseldorf, Fac Med, Dept Diagnost & Intervent Radiol, Moorenstr 5, D-40225 Dusseldorf, Germany
关键词
Size specific dose estimates; SSDE; dose monitoring; radiation protection; TUBE CURRENT; VARIABILITY; SELECTION; INDEXES; IMPACT; ADULT; TABLE;
D O I
10.1016/j.acra.2018.03.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To use an automatic computed tomography (CT) dose monitoring system to analyze the institutional chest and abdominopelvic CT dose data as regards the updated 2017 American College of Radiology (ACR) diagnostic reference levels (DRLs) based on water-equivalent diameter (Dw) and dose estimates (SSDE) to detect patient size subgroups in which CT dose can be optimized. Materials and Methods: All chest CT examinations performed between July 2016 and April 2017 with and without contrast material, CT of the pulmonary arteries, and abdominopelvic CT with and without contrast material were included in this retrospective study. Dw and SSDE were automatically calculated for all scans using a previously validated in-house developed Matlab software and stored into our CT dose monitoring system. CT dose data were analyzed as regards the updated ACR DRLs (size groups: 21-25 cm, 25-29 cm, 29-33 cm, 33-37 cm, 37-41 cm). SSDE and volumetric computed tomography dose index (CTDlvol) were used as CT dose parameter. Results: Overall, 30,002 CT examinations were performed in the study period, 3860 of which were included in the analysis (mean age 62.1 +/- 16.4 years, Dw 29.0 +/- 3.3 cm; n = 577 chest CT without contrast material, n = 628 chest CT with contrast material, n = 346 CT of chest pulmonary, n = 563 abdominopelvic CT without contrast material, n = 1746 abdominopelvic CT with contrast material). Mean SSDE and CTDlvol relative to the updated DRLs were 43.3 +/- 26.4 and 45.1 +/- 27.9% for noncontrast chest CT, 52.3 +/- 23.1 and 52.0 +/- 23.1% for contrast-enhanced chest CT, 68.8 +/- 29.5 and 70.0 +/- 31.0% for CT of pulmonary arteries, 41.9 +/- 29.2 and 43.3 +/- 31.3% for noncontrast abdominopelvic CT, and 56.8 +/- 22.2 and 58.8 +/- 24.4% for contrast-enhanced abdominopelvic CT. Lowest dose compared to the DRLs was found for the Dw group of 21-25 cm in noncontrast abdominopelvic CT (SSDE 30.4 +/- 21.8%, CTDlvol 30.8 +/- 21.4%). Solely the group of patients with a Dw of 37-41 cm undergoing noncontrast abdominopelvic CT exceeded the ACR DRL (SSDE 100.3 +/- 59.0%, CTDlvol 107.1 +/- 63.5%). Conclusions: On average, mean SSDE and CTDlvol of our institutional chest and abdominopelvic CT protocols were lower than the updated 2017 ACR DRLs. Size-specific subgroup analysis revealed a wide variability of SSDE and CTDlvol across CT protocols and patient size groups with a transgression of DRLs in noncontrast abdominopelvic CT of large patients (Dw 37-41 cm).
引用
收藏
页码:1624 / 1631
页数:8
相关论文
共 50 条
  • [21] Comparison of central, peripheral, and weighted size-specific dose in CT
    Choirul, Anam
    Adhianto, Dwi
    Sutanto, Heri
    Adi, Kusworo
    Ali, Mohd Hanafi
    Rae, William Ian Duncombe
    Fujibuchi, Toshioh
    Dougherty, Geoff
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (04) : 695 - 708
  • [22] Development of size-specific institutional diagnostic reference levels for computed tomography protocols in neck imaging
    Steuwe A.
    Thomas C.
    Kraus B.
    Bethge O.T.
    Aissa J.
    Klosterkemper Y.
    Antoch G.
    Boos J.
    Journal of Radiological Protection, 2020, 40 (01) : 68 - 82
  • [23] The impact of patient table on size-specific dose estimate (SSDE)
    Anam, Choirul
    Haryanto, Freddy
    Widita, Rena
    Arif, Idam
    Dougherty, Geoff
    McLean, Donald
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) : 153 - 158
  • [24] The impact of patient table on size-specific dose estimate (SSDE)
    Choirul Anam
    Freddy Haryanto
    Rena Widita
    Idam Arif
    Geoff Dougherty
    Donald McLean
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 153 - 158
  • [25] Implementation of Size-Dependent Local Diagnostic Reference Levels for CT Angiography
    Boere, Hub
    Eijsvoogel, Nienke G.
    Sailer, Anna M.
    Wildberger, Joachim E.
    de Haan, Michiel W.
    Das, Marco
    Jeukens, Cecile R. L. P. N.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (05) : W226 - W233
  • [26] Evolved size-specific dose estimates for patient-specific organ doses from chest CT scans based on hybrid patient size vectors
    Shao, Wencheng
    Yang, Ke
    Lou, Lizhi
    Lin, Xin
    Qu, Liangyong
    Zhuo, Weihai
    Liu, Haikuan
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2025,
  • [27] Size-Specific CT Dose Modulation for Low-Contrast Detectability
    James, J.
    Rana, V.
    Liang, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E454 - E454
  • [28] BODY SIZE-SPECIFIC EFFECTIVE DOSE CONVERSION COEFFICIENTS FOR CT SCANS
    Romanyukha, Anna
    Folio, Les
    Lamart, Stephanie
    Simon, Steven L.
    Lee, Choonsik
    RADIATION PROTECTION DOSIMETRY, 2016, 172 (04) : 428 - 437
  • [29] Consideration of the usefulness of a size-specific dose estimate in pediatric CT examination
    Tsujiguchi, Takakiyo
    Obara, Hideki
    Ono, Shuichi
    Saito, Yoko
    Kashiwakura, Ikuo
    JOURNAL OF RADIATION RESEARCH, 2018, 59 (04) : 430 - 435
  • [30] Assessment of patient size for size-specific dose estimates using two methods: a comparative study
    Abuhaimed, A.
    Martin, C.
    Demirkaya, O.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S906 - S906