Influence of microstructure of HC CoCrMo biomedical alloys on the corrosion and wear behaviour in simulated body fluids

被引:64
|
作者
Casaban Julian, Leandre [1 ]
Igual Munoz, Anna [1 ]
机构
[1] Univ Politecn Valencia, Dept Ingn Quim & Nucl, ETSI Ind, E-46071 Valencia, Spain
关键词
Bio-tribology; Corrosion-wear; Three-body abrasion; Sliding wear; CO-CR-MO; PASSIVE FILM; HIGH-CARBON; IN-VITRO; BIOLOGICAL ENVIRONMENTS; ORTHOPEDIC IMPLANTS; STAINLESS-STEEL; JOINT MATERIALS; SYNOVIAL-FLUID; TITANIUM-ALLOY;
D O I
10.1016/j.triboint.2010.10.033
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The corrosion and tribological behaviour of an as-cast High Carbon CoCrMo alloy subjected to different thermal treatments in simulated body fluids has been analyzed by electrochemical techniques. After the microstructural characterization of the alloy, the samples were studied electrochemically and tribo-electrochemically. Thermal treatments influence the corrosion behaviour, passive dissolution and tribological response. An increase of grain boundaries accelerates the anodic reaction in all solutions. A higher carbide volume fraction generates a lower wear-rate. Microscopic observation by means of Optical and SEM microscopy showed that presence of proteins modified the debris behaviour. In nonprotein containing solutions particles are dispersed away from the track while in protein solutions particles tend to agglomerate and sediment around the wear track. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:318 / 329
页数:12
相关论文
共 50 条
  • [31] Computer assisted corrosion analysis of hydroxyapatite coated CoCrMo biomedical alloys
    Coskun, M. Ibrahim
    Karahan, Ismail Hakki
    Golden, Teresa D.
    SURFACE & COATINGS TECHNOLOGY, 2015, 275 : E1 - E9
  • [32] Corrosion risk analysis of CoCrMo alloy as a function of microstructure: Biomedical applications
    Thapa, Maansi
    Sun, Yani
    Keaty, Bill
    Takoudis, Christos
    Mathew, Mathew
    SURFACE & COATINGS TECHNOLOGY, 2025, 497
  • [33] In vivo electrochemical corrosion study of a CoCrMo biomedical alloy in human synovial fluids
    Igual Munoz, A.
    Schwiesau, J.
    Jolles, B. M.
    Mischler, S.
    ACTA BIOMATERIALIA, 2015, 21 : 228 - 236
  • [34] Micro-abrasion mechanisms of cast CoCrMo in simulated body fluids
    Sun, D.
    Wharton, J. A.
    Wood, R. J. K.
    WEAR, 2009, 267 (11) : 1845 - 1855
  • [35] Corrosion behavior of biomedical AZ91 magnesium alloy in simulated body fluids
    Xin, Yunchang
    Liu, Chenglong
    Zhang, Xinmeng
    Tang, Guoyi
    Tian, Xiubo
    Chu, Paul K.
    JOURNAL OF MATERIALS RESEARCH, 2007, 22 (07) : 2004 - 2011
  • [36] Corrosion behavior of biomedical AZ91 magnesium alloy in simulated body fluids
    Xin Y.
    Liu C.
    Zhang X.
    Tang G.
    Tian X.
    Chu P.K.
    Journal of Materials Research, 2007, 22 (7) : 2004 - 2011
  • [37] Abrasive size and concentration effects on the tribo-corrosion of cast CoCrMo alloy in simulated body fluids Discussion
    Sun, D.
    Wharton, J. A.
    Wood, R. J. K.
    TRIBOLOGY INTERNATIONAL, 2009, 42 (11-12) : 1859 - 1859
  • [38] On corrosion behaviour of magnesium alloy AZ31 in simulated body fluids and influence of ionic liquid pretreatments
    Zhang, Y. F.
    Hinton, B.
    Wallace, G.
    Liu, X.
    Forsyth, M.
    CORROSION ENGINEERING SCIENCE AND TECHNOLOGY, 2012, 47 (05) : 374 - 382
  • [39] Investigation of the wear behaviour of metal/metal bearings of CoCrMo-alloys
    Piotrowski, A
    Bensmann, G
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2002, 33 (08) : 464 - 469
  • [40] Effects of Precipitates and Albumin in Simulated Body Fluids on Pin-on-Disk Wear Behavior of Biomedical Co-Cr-Mo Alloys
    Ueda, Kyosuke
    Kasamatsu, Motoka
    Tanno, Masanori
    Ueki, Kosuke
    Geringer, Jean
    Narushima, Takayuki
    MATERIALS TRANSACTIONS, 2016, 57 (12) : 2054 - 2059