Separate driving system for large area x-ray detector in radiology

被引:0
|
作者
Park, JK [1 ]
Lee, DG [1 ]
Choi, JY [1 ]
Suk, DW [1 ]
Chang, GW [1 ]
Moon, CW [1 ]
Nam, SH [1 ]
机构
[1] Inje Univ, Dept Biomed Engn, Radiat Image Lab, Kimhae, Kyungnam, South Korea
关键词
digital; imaging; detector; radiography; TFT; separate driving;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Flat-panel detectors for digital diagnostic imaging convert incident x-ray images to charge images. Flat panel detectors are becoming more interesting in real time medical x-ray imaging. Active area of flat panel detector is 14 x 17 inch. Detector is based on a 2560 x 3072 array of photoconductor and TFT pixels. X-ray conversion layer is deposited upper TFT array flat panel with 500 mu m by thermal deposition technology. Thickness uniformity of this layer is made of thickness control technology(<= 5%) of thermal deposition system. Each 139 mu m x 139 mu m pixel is made of thin film transistor technology, a storage capacitor and charge collection electrode having geometrical fill factor of 86%. Using the separate driving system of two dimensional mosaic modules for large area, that is able to take 4.2 seconds per frame to acquire an image. Imaging performance is suited for digital radiography imaging substituting by conventional radiography film system.
引用
收藏
页码:184 / 188
页数:5
相关论文
共 50 条
  • [41] Design and theoretical investigation of a digital x-ray detector with large area and high spatial resolution
    Gui, Jianbao
    Guo, Jinchuan
    Yang, Qinlao
    Liu, Xin
    Niu, Hanben
    FIFTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, PTS 1 AND 2, 2007, 6534
  • [42] Fabrication of Large Area X-ray Diffraction Grating for X-ray Phase Imaging
    Noda, Daiji
    Tokuoka, Atsushi
    Katori, Megumi
    Minamiyama, Yasuto
    Yamashita, Kenji
    Nishida, Satoshi
    Hattori, Tadashi
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 51 - 56
  • [43] Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/MR system
    Wen, Zhifei
    Fahrig, Rebecca
    Williams, Scott T.
    Pelc, Norbert J.
    MEDICAL PHYSICS, 2008, 35 (09) : 3895 - 3902
  • [44] 3 DIMENSIONAL DIGITAL X-RAY MICROTOMOGRAPHY WITH A MICROFOCAL X-RAY GENERATOR AND AN MWPC AREA DETECTOR
    BATEMAN, JE
    ROCKETT, P
    WEBB, S
    JOURNAL OF PHOTOGRAPHIC SCIENCE, 1989, 37 (3-4): : 92 - 97
  • [45] Development of an Area Image Sensor Pixel for an X-Ray Detector
    Suponnikov D.A.
    Putilin A.N.
    Tatarinova E.A.
    Zhgunev Z.G.
    Dabagov A.R.
    Russian Microelectronics, 2019, 48 (07): : 470 - 476
  • [46] X-RAY POLE FIGURE MEASUREMENT USING AN AREA DETECTOR
    KLEIN, H
    PARK, NJ
    NAUERGERHARDT, CU
    ZEITSCHRIFT FUR METALLKUNDE, 1994, 85 (08): : 574 - 580
  • [47] SPHERICAL DRIFT CHAMBER AREA DETECTOR FOR X-RAY CRYSTALLOGRAPHY
    BOLON, C
    DEUTSCH, M
    LANZA, R
    QUIGLEY, G
    RICH, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (01) : 146 - 149
  • [48] X-ray imaging using CCD based area detector
    Sinha, A
    SOLID STATE PHYSICS, VOL 41, 1998, 1999, : 71 - 74
  • [49] ECONOMICAL X-RAY AREA DETECTOR FOR FOCUSING AND ALIGNMENT PURPOSES
    CHU, B
    ROUSSEAU, J
    GAO, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (08): : 4000 - 4002
  • [50] Large-area pixellated photon counting X-ray imaging system
    Iles, G
    Mathieson, K
    Murray, P
    Passmore, S
    Prydderch, M
    Seller, P
    Thomas, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 427 - 430