Separate driving system for large area x-ray detector in radiology

被引:0
|
作者
Park, JK [1 ]
Lee, DG [1 ]
Choi, JY [1 ]
Suk, DW [1 ]
Chang, GW [1 ]
Moon, CW [1 ]
Nam, SH [1 ]
机构
[1] Inje Univ, Dept Biomed Engn, Radiat Image Lab, Kimhae, Kyungnam, South Korea
关键词
digital; imaging; detector; radiography; TFT; separate driving;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Flat-panel detectors for digital diagnostic imaging convert incident x-ray images to charge images. Flat panel detectors are becoming more interesting in real time medical x-ray imaging. Active area of flat panel detector is 14 x 17 inch. Detector is based on a 2560 x 3072 array of photoconductor and TFT pixels. X-ray conversion layer is deposited upper TFT array flat panel with 500 mu m by thermal deposition technology. Thickness uniformity of this layer is made of thickness control technology(<= 5%) of thermal deposition system. Each 139 mu m x 139 mu m pixel is made of thin film transistor technology, a storage capacitor and charge collection electrode having geometrical fill factor of 86%. Using the separate driving system of two dimensional mosaic modules for large area, that is able to take 4.2 seconds per frame to acquire an image. Imaging performance is suited for digital radiography imaging substituting by conventional radiography film system.
引用
收藏
页码:184 / 188
页数:5
相关论文
共 50 条
  • [1] The ''RAPID'' high rate large area X-ray detector system
    Lewis, RA
    Helsby, WI
    Jones, AO
    Hall, CJ
    Parker, B
    Sheldon, J
    Clifford, P
    Hillen, M
    Sumner, I
    Fore, NS
    Jones, RWM
    Roberts, KM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3): : 32 - 41
  • [2] A large area MCP detector for X-ray imaging
    Lees, JE
    Pearson, JF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 384 (2-3): : 410 - 424
  • [3] A LARGE-AREA DETECTOR FOR X-RAY APPLICATIONS
    RODRICKS, B
    HUANG, Q
    HOPF, R
    WANG, KM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 572 - 576
  • [4] The Large Area Detector of LOFT: the Large Observatory for X-ray Timing
    Zane, S.
    Walton, D.
    Kennedy, T.
    Feroci, M.
    Den Herder, J. -W.
    Ahangarianabhari, M.
    Argan, A.
    Azzarello, P.
    Baldazzi, G.
    Barbera, M.
    Barret, D.
    Bertuccio, G.
    Bodin, P.
    Bozzo, E.
    Bradley, L.
    Cadoux, F.
    Cais, P.
    Campana, R.
    Coker, J.
    Cros, A.
    Del Monte, E.
    De Rosa, A.
    Di Cosimo, S.
    Donnarumma, I.
    Evangelista, Y.
    Favrel, Y.
    Feldmann, C.
    Fraser, G.
    Fuschino, F.
    Grassi, M.
    Hailey, M. R.
    Hudec, R.
    Labanti, C.
    Macera, D.
    Malcovati, P.
    Marisaldi, M.
    Martindale, A.
    Mineo, T.
    Muleri, F.
    Nowak, M.
    Orlandini, M.
    Pacciani, L.
    Perinati, E.
    Petracek, V.
    Pohl, M.
    Rachevski, A.
    Smith, P.
    Santangelo, A.
    Seyler, J. -Y.
    Schmid, C.
    SPACE TELESCOPES AND INSTRUMENTATION 2014: ULTRAVIOLET TO GAMMA RAY, 2014, 9144
  • [5] Large area a-Si X-ray detector for NDT
    Munier, B
    Casagrande, JM
    Koch, A
    NDT IN PROGRESS, PROCEEDINGS: MEETING OF NDT - EXPERTS, 2001, : 161 - 168
  • [6] A Large Area Detector proposed for the Large Observatory for X-ray Timing (LOFT)
    Zane, S.
    Walton, D.
    Kennedy, T.
    Feroci, M.
    Den Herder, J. -W.
    Ahangarianabhari, M.
    Argan, A.
    Azzarello, P.
    Baldazzi, G.
    Barret, D.
    Bertuccio, G.
    Bodin, P.
    Bozzo, E.
    Cadoux, F.
    Cais, P.
    Campana, R.
    Coker, J.
    Cros, A.
    Del Monte, E.
    De Rosa, A.
    Di Cosimo, S.
    Donnarumma, I.
    Evangelista, Y.
    Favre, Y.
    Feldman, C.
    Fraser, G.
    Fuschino, F.
    Grassi, M.
    Hailey, M. R.
    Hudec, R.
    Labanti, C.
    Macera, D.
    Malcovati, P.
    Marisaldi, M.
    Martindale, A.
    Mineo, T.
    Muleri, F.
    Nowak, M.
    Orlandini, M.
    Pacciani, L.
    Perinati, E.
    Petracek, V.
    Pohl, M.
    Rachevski, A.
    Smith, P.
    Santangelo, A.
    Seyler, J. -Y.
    Schmid, C.
    Soffitta, P.
    Suchy, S.
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [7] Large area direct X-ray conversion detector for protein crystallography
    Sultana, Afrin
    Karim, K. S.
    Rowlands, J. A.
    2008 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-4, 2008, : 947 - 950
  • [8] Large area position sensitive X-ray detector for astrophysical observations
    Mels, W.A.
    Lowes, P.
    Buurmans, H.B.
    Brinkman, A.C.
    Naber, A.P.
    Rook, A.
    Zandee, W.
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 689 - 695
  • [9] A large area CCD X-ray detector for exotic atom spectroscopy
    Nelms, N
    Anagnostopoulos, DF
    Ayranov, O
    Borchert, G
    Egger, JP
    Gotta, D
    Hennebach, M
    Indelicato, P
    Leoni, B
    Liu, YW
    Manil, B
    Simons, LM
    Wells, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3): : 419 - 431
  • [10] A large area photon counting X-ray detector with indirect conversion
    Durst, Roger
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2021, 77 : A205 - A205