Application of design for six sigma methodology on portable water filter that uses membrane filtration system: A preliminary study

被引:4
|
作者
Hassan, Mohd Fahrul [1 ]
Jusoh, Suhada [1 ]
Yunos, Muhamad Zaini [1 ]
Arifin, A. M. T. [1 ]
Ismail, A. E. [1 ]
Ibrahim, M. Rasidi [1 ]
Rahim, M. Zulafif [1 ]
机构
[1] Univ Tun Hussein Onn Malaysia, Fac Mech & Mfg Engn, Batu Pahat 86400, Johor, Malaysia
关键词
D O I
10.1088/1757-899X/243/1/012048
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Portable water filter has grown significantly in recent years. The use of water bottles as a water drink stuff using hand pump water filtration unit has been suggested to replace water bottled during outdoor recreational activities and for emergency supplies. However, quality of water still the issue related to contaminated water due to the residual waste plants, bacteria, and so on. Based on these issues, the study was carried out to design a portable water filter that uses membrane filtration system by applying Design for Six Sigma. Design for Six Sigma methodology consists of five stages which is Define, Measure, Analyze, Design and Verify. There were several tools have been used in each stage in order to come out with a specific objective. In the Define stage, questionnaire approach was used to identify the needs of portable water filter in the future from potential users. Next, Quality Function Deployment (QFD) tool was used in the Measure stage to measure the users' needs into engineering characteristics. Based on the information in the Measure stage, morphological chart and weighted decision matrix tools were used in the Analyze stage. This stage performed several activities including concept generation and selection. Once the selection of the final concept completed, detail drawing was made in the Design stage. Then, prototype was developed in the Verify stage to conduct proof-of-concept testing. The results that obtained from each stage have been reported in this paper. From this study, it can be concluded that the application of Design for Six Sigma in designing a future portable water filter that uses membrane filtration system is a good start in looking for a new alternative concept with a completed supporting document.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] PRELIMINARY STUDY ON DESIGN AND DEVELOPMENT OF A JOURNAL FOCUSED CRAWLER SYSTEM USING EBD METHODOLOGY: PART I - DESIGN TASK AND ENVIRONMENT ANALYSIS
    Wang, Hansong
    Wang, Xiaoying
    Wang, Yixuan
    Bhattacharjee, Amitava
    Basireddy, Shiva Kumar
    Cherian, Anusha
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON INNOVATIVE DESIGN AND MANUFACTURING (ICIDM), 2014, : 59 - 64
  • [42] Decentralized Membrane Filtration System for Sustainable and Safe Drinking Water Supply in Low-Income Countries: Baseline Study
    Huang, Haiou
    Jacangelo, Joseph G.
    Schwab, Kellogg J.
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2011, 137 (11): : 981 - 989
  • [43] Membrane Filter Replacement System for Portable South Kalimantan Peat Water Treatment Solar-Powered Using Fuzzy Inference System Takagi-Sugeno-Kang Method
    Nugrahadi, Dodon Turianto
    Wianto, Totok
    Alwahdy, Muhammad Fajar
    Nugroho, Radityo Adi
    Farmadi, Andi
    Wahyono, Sri Cahyo
    Faisal, Mohammad Reza
    Budiman, Irwan
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2024, 33 (05): : 5239 - 5247
  • [44] Preliminary study of system design and safety analysis methodology for supercritical carbon dioxide Brayton cycle direct-cooled reactor system
    Gao, Chuntian
    Wu, Pan
    Shan, Jianqiang
    Huang, Yanping
    Zhang, Jibin
    Wang, Lianjie
    ANNALS OF NUCLEAR ENERGY, 2020, 147
  • [45] Application of graphene oxide/titanium dioxide nanoparticle on the rheological, filtration and shale swelling characteristics in water-based mud system: experimental and full factorial design study
    Lalji, Shaine Mohammadali
    Haneef, Javed
    Hashmi, Saud
    CHEMICAL PAPERS, 2024, 78 (08) : 5085 - 5101
  • [46] Micro-pore ceramic filter and UV system as ballast water treatment:: Preliminary study on Chlorella removal and bacteria inactivation
    Zhang, Manxia
    Xu, Ningwei
    Li, Chang Ii
    Wang, Yatong
    Zhu, Yimin
    JOURNAL OF ADVANCED OXIDATION TECHNOLOGIES, 2008, 11 (01) : 125 - 129
  • [47] Comparison study of membrane filtration direct count and an automated coliform and Escherichia coli detection system for on-site water quality testing
    Habash, Marc
    Johns, Robert
    JOURNAL OF MICROBIOLOGICAL METHODS, 2009, 79 (01) : 128 - 130
  • [48] Application of a six sigma model to evaluate the analytical performance of cerebrospinal fluid biochemical analytes and the design of quality control strategies for these assays: A single-centre study
    Liu, Qian
    Hu, Ming
    Yang, Fang
    Li, Yan
    Yang, Fumeng
    CLINICAL BIOCHEMISTRY, 2023, 114 : 73 - 78
  • [49] Lead-imprinted polyvinylidene fluoride membrane for selective removal of lead from contaminated water: material fabrication, filtration application, and mechanism study
    Zhao, Dandan
    Fu, Chen
    Lin, Sudan
    Xu, Yongzhi
    He, Haoran
    Liu, Siyuan
    Shi, Xueqing
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (41) : 94195 - 94204
  • [50] Lead-imprinted polyvinylidene fluoride membrane for selective removal of lead from contaminated water: material fabrication, filtration application, and mechanism study
    Dandan Zhao
    Chen Fu
    Sudan Lin
    Yongzhi Xu
    Haoran He
    Siyuan Liu
    Xueqing Shi
    Environmental Science and Pollution Research, 2023, 30 : 94195 - 94204