T2 mapping of the heart with a double-inversion radial fast spin-echo method with indirect echo compensation

被引:9
|
作者
Hagio, Tomoe [1 ]
Huang, Chuan [2 ,3 ]
Abidov, Aiden [4 ,5 ]
Singh, Jaspreet [4 ]
Ainapurapu, Bujji [4 ]
Squire, Scott [6 ]
Bruck, Denise [5 ]
Altbach, Maria I. [6 ]
机构
[1] Univ Arizona, Biomed Engn Grad Interdisciplinary Program, Tucson, AZ USA
[2] Univ Arizona, Dept Math, Tucson, AZ 85721 USA
[3] SUNY Stony Brook, Dept Radiol & Psychiat, Stony Brook, NY 11794 USA
[4] Univ Arizona, Dept Med, Tucson, AZ USA
[5] Univ Arizona, Arizona Sarver Heart Ctr, Tucson, AZ USA
[6] Univ Arizona, Dept Med Imaging, Tucson, AZ 85721 USA
关键词
Cardiovascular magnetic resonance; Myocarditis; Edema; T2; Mapping; Radial; FSE; Indirect echo; CARDIOVASCULAR MAGNETIC-RESONANCE; REPERFUSED MYOCARDIAL-INFARCTION; LATE GADOLINIUM ENHANCEMENT; RISK; MRI; RECONSTRUCTION; SEQUENCE; SALVAGE; AREA; QUANTIFICATION;
D O I
10.1186/s12968-015-0108-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The abnormal signal intensity in cardiac T-2-weighted images is associated with various pathologies including myocardial edema. However, the assessment of pathologies based on signal intensity is affected by the acquisition parameters and the sensitivities of the receiver coils. T-2 mapping has been proposed to overcome limitations of T-2-weighted imaging, but most methods are limited in spatial and/or temporal resolution. Here we present and evaluate a double inversion recovery radial fast spin-echo (DIR-RADFSE) technique that yields data with high spatiotemporal resolution for cardiac T-2 mapping. Methods: DIR-RADFSE data were collected at 1.5 T on phantoms and subjects with echo train length (ETL) = 16, receiver bandwidth (BW) = +/- 32 kHz, TR = 1RR, matrix size = 256 x 256. Since only 16 views per echo time (TE) are collected, two algorithms designed to reconstruct highly undersampled radial data were used to generate images for 16 time points: the Echo-Sharing (ES) and the CUrve Reconstruction via pca-based Linearization with Indirect Echo compensation (CURLIE) algorithm. T-2 maps were generated via least-squares fitting or the Slice-resolved Extended Phase Graph (SEPG) model fitting. The CURLIE-SEPG algorithm accounts for the effect of indirect echoes. The algorithms were compared based on reproducibility, using Bland-Altman analysis on data from 7 healthy volunteers, and T-2 accuracy (against a single-echo spin-echo technique) using phantoms. Results: Both reconstruction algorithms generated in vivo images with high spatiotemporal resolution and showed good reproducibility. Mean T-2 difference between repeated measures and the coefficient of repeatability were 0.58 ms and 2.97 for ES and 0.09 ms and 4.85 for CURLIE-SEPG. In vivo T-2 estimates from ES were higher than those from CURLIE-SEPG. In phantoms, CURLIE-SEPG yielded more accurate T(2)s compared to reference values (error was 7.5-13.9% for ES and 0.6-2.1% for CURLIE-SEPG), consistent with the fact that CURLIE-SEPG compensates for the effects of indirect echoes. The potential of T-2 mapping with CURLIE-SEPG is demonstrated in two subjects with known heart disease. Elevated T-2 values were observed in areas of suspected pathology. Conclusions: DIR-RADFSE yielded TE images with high spatiotemporal resolution. Two algorithms for generating T-2 maps from highly undersampled data were evaluated in terms of accuracy and reproducibility. Results showed that CURLIE-SEPG yields T-2 estimates that are reproducible and more accurate than ES.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Liver MR imaging: Comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery
    Keogan, MT
    Spritzer, CE
    Paulson, EK
    Paine, SS
    Harris, L
    Dahlke, JL
    MacFall, JR
    ABDOMINAL IMAGING, 1996, 21 (05): : 433 - 439
  • [22] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [23] SURFACE EFFECTS MEASURED BY ADDITIONAL ECHO DECAY IN THE T2 HAHN SPIN-ECHO EXPERIMENT
    LEON, V
    DIAZ, H
    APPLIED SPECTROSCOPY, 1986, 40 (03) : 416 - 416
  • [24] MRI in characterisation of focal liver lesions: Comparison of T2 weighting by conventional spin-echo and turbo spin-echo sequences
    Giovagnoni, A
    Paci, E
    Valeri, G
    Ercolani, P
    Gesuita, R
    Carle, F
    Piga, A
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04) : 589 - 595
  • [25] Abdominal T2-Weighted Imaging and T2 Mapping Using a Variable Flip Angle Radial Turbo Spin-Echo Technique
    Keerthivasan, Mahesh B.
    Galons, Jean-Philippe
    Johnson, Kevin
    Umapathy, Lavanya
    Martin, Diego R.
    Bilgin, Ali
    Altbach, Maria, I
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 289 - 300
  • [26] A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage
    Vladimir Juras
    Klaus Bohndorf
    Rahel Heule
    Claudia Kronnerwetter
    Pavol Szomolanyi
    Benedikt Hager
    Oliver Bieri
    Stefan Zbyn
    Siegfried Trattnig
    European Radiology, 2016, 26 : 1905 - 1912
  • [27] MRI screening of the cerebellopontine angle and inner ear with fast spin-echo T2 technique
    Kovacsovics, B
    Davidsson, L
    Harder, H
    Magnuson, B
    Ledin, T
    ARCHIVES ITALIENNES DE BIOLOGIE, 2000, 138 (01): : 87 - 92
  • [28] A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage
    Juras, Vladimir
    Bohndorf, Klaus
    Heule, Rahel
    Kronnerwetter, Claudia
    Szomolanyi, Pavol
    Hager, Benedikt
    Bieri, Oliver
    Zbyn, Stefan
    Trattnig, Siegfried
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1905 - 1912
  • [29] APPLICATION OF FAST SPIN-ECHO T(2)-WEIGHTED IMAGING FOR EXAMINATION OF THE NEUROCRANIUM - COMPARISON WITH THE CONVENTIONAL T(2)-WEIGHTED SPIN-ECHO SEQUENCE
    SIEWERT, C
    HOSTEN, N
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01): : 44 - 50
  • [30] Fast Open-Source Toolkit for Water T2 Mapping in the Presence of Fat From Multi-Echo Spin-Echo Acquisitions for Muscle MRI
    Santini, Francesco
    Deligianni, Xeni
    Paoletti, Matteo
    Solazzo, Francesca
    Weigel, Matthias
    de Sousa, Paulo Loureiro
    Bieri, Oliver
    Monforte, Mauro
    Ricci, Enzo
    Tasca, Giorgio
    Pichiecchio, Anna
    Bergsland, Niels
    FRONTIERS IN NEUROLOGY, 2021, 12