Classification of distal radius fractures: An analysis of interobserver reliability and intraobserver reproducibility

被引:131
|
作者
Andersen, DJ [1 ]
Blair, WF [1 ]
Steyers, CM [1 ]
Adams, BD [1 ]
ElKhouri, GY [1 ]
Brandser, EA [1 ]
机构
[1] UNIV IOWA,DEPT ORTHOPAED,DIV HAND & MICROSURG,IOWA CITY,IA
来源
关键词
D O I
10.1016/S0363-5023(96)80006-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Frykman, Melone, Mayo, and AO classification systems for distal radius fractures were evaluated for interobserver reliability and intraobserver reproducibility in a clinical setting using initial plain radiographs. Two attending orthopedic hand surgeons and two attending radiologists classified 55 sets of distal radius fractures. kappa-statistics were used to establish a relative level of agreement between observers for the two readings and between separate readings by the same observer. Interobserver agreement was rated as moderate for the Mayo classification and fair for the Frykman, Melone, and AO classifications. Intraobserver agreement was substantial for only one of four observers for each of the Frykman, Melone, and Mayo, while the remaining three observers achieved only fair to moderate reproducibility. Intraobserver agreement for the AO classification was fair for all four of the observers. Neither interobserver or intraobserver agreement was affected by combining similar subclasses in the Melone classification or by reducing the number of categories in the AO system from 27 to 9. However, further reducing the AO system to its three main types brought agreement to the ''substantial'' level. No difference was found in interobserver agreement between the first and second readings or in interobserver or intraobserver agreement between orthopedic hand surgeons and radiologists. Understanding the limitations of fracture classifications based solely on plain radiographs can help avoid undue reliance on them. Given the low degree of interobserver and intraobserver agreement for each of the distal radius fracture classifications in this study, their use as the sole means for determining the direction of treatment or for the direct comparison of results among different studies is not warranted.
引用
收藏
页码:574 / 582
页数:9
相关论文
共 50 条
  • [21] Interobserver reliability and intraobserver reproducibility of the modified Ficat classification system of osteonecrosis of the femoral head
    Smith, SW
    Meyer, RA
    Connor, PM
    Smith, SE
    Hanley, EN
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (11): : 1702 - 1706
  • [22] Poor interobserver reliability of AO classification of fractures of the distal radius -: Additional computed tomography is of minor value
    Flinkkilä, T
    Nikkola-Sihto, A
    Kaarela, O
    Pääkkö, E
    Raatikainen, T
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (04): : 670 - 672
  • [23] Classification of distal radius fractures in children: good inter- and intraobserver reliability, which improves with clinical experience
    Randsborg, Per-Henrik
    Sivertsen, Einar A.
    BMC MUSCULOSKELETAL DISORDERS, 2012, 13
  • [24] Classification of distal radius fractures in children: good inter- and intraobserver reliability, which improves with clinical experience
    Per-Henrik Randsborg
    Einar A Sivertsen
    BMC Musculoskeletal Disorders, 13
  • [25] Intraobserver and Interobserver Reliability of Radiographic Analysis of Proximal Humerus Fractures in Adolescents
    Burke, Michelle C.
    Minnock, Christopher
    Robbins, Christopher B.
    Abbott, Matthew D.
    Caird, Michelle S.
    Farley, Frances A.
    Kirsch, Jacob
    Thomas, Jared
    Li, Ying
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2019, 39 (02) : E125 - E129
  • [26] INTEROBSERVER AND INTRAOBSERVER RELIABILITY IN THE CLINICAL CLASSIFICATION OF DRUSEN
    BRESSLER, SB
    BRESSLER, NM
    SEDDON, JM
    GRAGOUDAS, ES
    JACOBSON, LP
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1988, 8 (02): : 102 - 108
  • [27] Interobserver and intraobserver reliability of two classification systems for intra-articular calcaneal fractures
    Lauder, AJ
    Inda, DJ
    Bott, AM
    Clare, MP
    Fitzgibbons, TC
    Mormino, MA
    FOOT & ANKLE INTERNATIONAL, 2006, 27 (04) : 251 - 255
  • [28] New Classification System for Proximal Fifth Metatarsal Fractures: Intraobserver and Interobserver Reliability Assessment
    Fernandez-Rojas, Enrique
    Araya-Bonilla, Victor
    Barra-Dinamarca, Emilio
    Pastor-Villablanca, Juan
    Mortada-Mahmoud, Ahmed
    Alvarado-Livacic, Cristobal
    Vila-Rico, Jesus
    FOOT & ANKLE INTERNATIONAL, 2025, 46 (02) : 246 - 254
  • [29] An independent evaluation on the interobserver reliability and intraobserver reproducibility of Toyama classification system for cervical dumbbell tumors
    Yin, Mengchen
    Huang, Quan
    Sun, Zhengwang
    Gao, Xin
    Chen, Guanghui
    He, Shaohui
    Xia, Ye
    Ma, Junming
    Mo, Wen
    Xiao, Jianru
    MEDICINE, 2017, 96 (10)
  • [30] Interobserver reliability and intraobserver reproducibility of the system of King et al. for the classification of adolescent idiopathic scoliosis
    Cummings, RJ
    Loveless, EA
    Campbell, J
    Samelson, S
    Mazur, JM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (08): : 1107 - 1111