Classification of distal radius fractures: An analysis of interobserver reliability and intraobserver reproducibility

被引:131
|
作者
Andersen, DJ [1 ]
Blair, WF [1 ]
Steyers, CM [1 ]
Adams, BD [1 ]
ElKhouri, GY [1 ]
Brandser, EA [1 ]
机构
[1] UNIV IOWA,DEPT ORTHOPAED,DIV HAND & MICROSURG,IOWA CITY,IA
来源
关键词
D O I
10.1016/S0363-5023(96)80006-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Frykman, Melone, Mayo, and AO classification systems for distal radius fractures were evaluated for interobserver reliability and intraobserver reproducibility in a clinical setting using initial plain radiographs. Two attending orthopedic hand surgeons and two attending radiologists classified 55 sets of distal radius fractures. kappa-statistics were used to establish a relative level of agreement between observers for the two readings and between separate readings by the same observer. Interobserver agreement was rated as moderate for the Mayo classification and fair for the Frykman, Melone, and AO classifications. Intraobserver agreement was substantial for only one of four observers for each of the Frykman, Melone, and Mayo, while the remaining three observers achieved only fair to moderate reproducibility. Intraobserver agreement for the AO classification was fair for all four of the observers. Neither interobserver or intraobserver agreement was affected by combining similar subclasses in the Melone classification or by reducing the number of categories in the AO system from 27 to 9. However, further reducing the AO system to its three main types brought agreement to the ''substantial'' level. No difference was found in interobserver agreement between the first and second readings or in interobserver or intraobserver agreement between orthopedic hand surgeons and radiologists. Understanding the limitations of fracture classifications based solely on plain radiographs can help avoid undue reliance on them. Given the low degree of interobserver and intraobserver agreement for each of the distal radius fracture classifications in this study, their use as the sole means for determining the direction of treatment or for the direct comparison of results among different studies is not warranted.
引用
收藏
页码:574 / 582
页数:9
相关论文
共 50 条
  • [1] INTEROBSERVER RELIABILITY AND INTRAOBSERVER REPRODUCIBILITY OF THE FERNANDEZ CLASSIFICATION FOR DISTAL RADIUS FRACTURES
    Naqvi, S. G. A.
    Reynolds, T.
    Kitsis, C.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (04) : 483 - 485
  • [2] The interobserver and intraobserver reliability of the cooney classification of distal radius fractures between experienced orthopaedic surgeons
    Jin, W. -J.
    Jiang, L. -S.
    Shen, L.
    Lu, H.
    Cui, Y. -M.
    Zhou, Q.
    Dai, L. -Y.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2007, 32E (05) : 509 - 511
  • [3] Interobserver Agreement and Intraobserver Reproducibility of Barzullah Working Classification of Distal End Radius Fractures among Orthopaedic Residents
    Kamal, Younis
    Khan, Hayat Ahmad
    Gani, Naseem U. I.
    Farooq, Munir
    Shah, Adil Bashir
    Khan, Mohammad Ashraf
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (01): : 24 - 29
  • [4] THE NEER-CLASSIFICATION-SYSTEM FOR PROXIMAL HUMERAL FRACTURES - AN ASSESSMENT OF INTEROBSERVER RELIABILITY AND INTRAOBSERVER REPRODUCIBILITY
    SIDOR, ML
    ZUCKERMAN, JD
    LYON, T
    KOVAL, K
    CUOMO, F
    SCHOENBERG, N
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (12): : 1745 - 1750
  • [5] Interobserver and intraobserver variation in classification systems for fractures of the distal humerus
    Wainwright, AI
    Williams, JR
    Carr, AJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (05): : 636 - 642
  • [6] Reliability and reproducibility of classifications for distal radius fractures
    Kucuk, Levent
    Kumbaraci, Mert
    Gunay, Huseyin
    Karapinar, Levent
    Ozdemir, Oguz
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2013, 47 (03) : 153 - 157
  • [7] EVANS CLASSIFICATION OF TROCHANTERIC FRACTURES - AN ASSESSMENT OF THE INTEROBSERVER AND INTRAOBSERVER RELIABILITY
    ANDERSEN, E
    JORGENSEN, LG
    HEDEDAM, LT
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1990, 21 (06): : 377 - 378
  • [8] Letournel classification for acetabular fractures -: Assessment of interobserver and intraobserver reliability
    Beaulé, PE
    Dorey, FJ
    Matta, JM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (09): : 1704 - 1709
  • [9] Interobserver Reliability and Intraobserver Reproducibility of Three Radiological Classification Systems for Intra-articular Calcaneal Fractures
    Sayed-Noor, Arkan S.
    Agren, Per-Henrik
    Wretenberg, Per
    FOOT & ANKLE INTERNATIONAL, 2011, 32 (09) : 861 - 866
  • [10] The acquired midtarsus deformity classification system - Interobserver reliability and intraobserver reproducibility
    Schon, LC
    Easley, ME
    Cohen, I
    Lam, PWC
    Badekas, A
    Anderson, CD
    FOOT & ANKLE INTERNATIONAL, 2002, 23 (01) : 30 - 36