Implementation of a Software Feedback Control for the CMS Monitoring Lasers

被引:0
|
作者
Zhang, Liyuan [1 ]
Bailleux, David [1 ]
Bornheim, Adolf [1 ]
Zhu, Kejun [1 ]
Zhu, Ren-yuan [1 ]
机构
[1] CALTECH, Pasadena, CA 91125 USA
关键词
Calorimeter; lead tungstate crystal; radiation damage; laser monitoring; feedback control;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Light monitoring will play a crucial role in maintaining energy resolution for the CMS lead tungstate crystal calorimeter in situ at LHC. Since 2003, a laser based monitoring system in its final design has been installed and used in beam tests at CERN. While the stability of the laser pulse energy and FWHM width, measured in 24 hours, is at 3% level, a long term degradation and a drift of the laser pulse center timing at 2 ns/day were observed. The degradation and drift were caused by the aging of the DC Kr lamp used to pump the Nd:YLF laser, and would affect the monitoring precision. This paper presents the design and implementation of a software feedback control which stabilizes laser pulse energy, width and timing by trimming the Nd: YLF laser pumping current. For laser runs lasted for more than 650 hours a stability of pulse energy and FWHM width at 3% level and a pulse timing jitter at 2 ns have been achieved when the laser pulse center timing is used as the feedback parameter.
引用
收藏
页码:435 / 439
页数:5
相关论文
共 50 条
  • [31] Design and implementation of computer control software
    Moallem, M
    IEEE CONTROL SYSTEMS MAGAZINE, 2005, 25 (01): : 26 - 29
  • [32] Software Implementation for ACIM Motor Control
    Aghion, Cristian
    Ursaru, Ovidiu
    Lucanu, Mihai
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (02): : 433 - 436
  • [33] DESIGN AND IMPLEMENTATION OF SOFTWARE FOR CONTROL EDUCATION
    SCHAUFELBERGER, W
    IEEE TRANSACTIONS ON EDUCATION, 1990, 33 (03) : 291 - 297
  • [34] The Detector Control Unit:: an ASIC for the monitoring of the CMS silicon tracker
    Magazzù, G
    Marchioro, A
    Moreira, P
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1206 - 1209
  • [35] The detector control unit:: An ASIC for the monitoring of the CMS silicon tracker
    Magazzù, G
    Marchioro, A
    Moreira, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1333 - 1336
  • [36] POLARIZATION CONTROL BY OPTICAL FEEDBACK IN SEMICONDUCTOR-LASERS
    TODA, T
    OGASAWARA, N
    ITO, R
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1988, 27 (09): : 1702 - 1707
  • [37] Dynamic control of semiconductor lasers by delayed optical feedback
    Simmendinger, C
    Hess, O
    PHYSICS AND SIMULATION OF OPTOELECTRONIC DEVICES IV, 1996, 2693 : 666 - 677
  • [38] Feedback control of the intensity noise of injection locked lasers
    Huntington, Elanor H.
    Buchler, Ben C.
    Harb, Charles C.
    Ralph, Timothy C.
    McClelland, David E.
    Bachor, Hans-A.
    Optics Communications, 1997, 145 (1-6): : 359 - 366
  • [39] Feedback control fine-tunes WDM lasers
    Powell, PN
    LASER FOCUS WORLD, 2000, : 10 - 10
  • [40] Feedback control of the intensity noise of injection locked lasers
    Huntington, EH
    Harb, CC
    Buchler, BC
    Ralph, TC
    LASER RESONATORS II, 1999, 3611 : 73 - 78