Monte Carlo simulation of the imaging properties of scintillator-coated X-ray pixel detectors

被引:9
|
作者
Hjelm, M [1 ]
Norlin, B
Nilsson, HE
Fröjdh, C
Badel, X
机构
[1] Mid Sweden Univ, Dept Informat Technol & Media, SE-85170 Sundsvall, Sweden
[2] Royal Inst Technol, Dept Microelect & Informat Technol, SE-16440 Kista, Sweden
关键词
X-ray; signal-to-noise ratio; Monte Carlo simulation; imaging; pixel detector; scintillating screen;
D O I
10.1016/S0168-9002(03)01553-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The spatial resolution of scintillator-coated X-ray pixel detectors is usually limited by the isotropic light spread in the scintillator. One way to overcome this limitation is to use a pixellated scintillating layer on top of the semiconductor pixel detector. Using advanced etching and filling techniques, arrays of CsI columns have been successfully fabricated and characterized. Each CsI waveguide matches one pixel of the semiconductor detector, limiting the spatial spread of light. Another concept considered in this study is to detect the light emitted from the scintillator by diodes formed in the silicon pore walls. There is so far no knowledge regarding the theoretical limits for these two approaches, which makes the evaluation of the fabrication process difficult. In this work we present numerical calculations of the signal-to-noise ratio (SNR) for detector designs based on scintillator-filled pores in silicon. The calculations are based on separate Monte Carlo (MC) simulations of X-ray absorption and light transport in scintillator waveguides. The resulting data are used in global MC simulations of flood exposures of the detector array, from which the SNR values are obtained. Results are presented for two scintillator materials, namely CsI (Tl) and GADOX. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:76 / 85
页数:10
相关论文
共 50 条
  • [41] Monte Carlo simulation of discrete γ-ray detectors
    Bakkali, A
    Tamda, N
    Parmentier, M
    Chavanelle, J
    Pousse, A
    Kastler, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 545 (03): : 699 - 704
  • [42] Monte Carlo simulator for x-ray spectra analysis of GaAs detectors
    Cola, A
    Reggiani, L
    Vasanelli, L
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 : 392 - 399
  • [43] A Geant4-based Monte Carlo X-ray imaging simulation platform
    Li, Ouyi
    Gao, Jianhua
    Zhang, Qiong
    APPLIED RADIATION AND ISOTOPES, 2024, 210
  • [44] Monte-Carlo simulation of a slot-scanning X-ray imaging system
    Kulkarni, Mayuresh
    Dendere, Ronald
    Nicolls, Fred
    Steiner, Stef
    Douglas, Tania S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 284 - 289
  • [45] Inclusion of coherence in Monte Carlo models for simulation of x-ray phase contrast imaging
    Cipiccia, Silvia
    Vittoria, Fabio A.
    Weikum, Maria
    Olivo, Alessandro
    Jaroszynski, Dino A.
    OPTICS EXPRESS, 2014, 22 (19): : 23480 - 23488
  • [46] X-ray imaging plate performance investigation based on a Monte Carlo simulation tool
    Yao, M.
    Duvauchelle, Ph
    Kaftandjian, V.
    Peterzol-Parmentier, A.
    Schumm, A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 103 : 84 - 91
  • [47] Voxel-based Monte Carlo simulation of X-ray imaging and spectroscopy experiments
    Bottigli, U
    Brunetti, A
    Golosio, B
    Oliva, P
    Stumbo, S
    Vincze, L
    Randaccio, P
    Bleuet, P
    Simionovici, A
    Somogyi, A
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (10-11) : 1747 - 1754
  • [48] Monte Carlo simulation of an x-ray volume imaging cone beam CT unit
    Spezi, Emiliano
    Downes, Patrick
    Radu, Emil
    Jarvis, Richard
    MEDICAL PHYSICS, 2009, 36 (01) : 127 - 136
  • [49] A Monte Carlo simulation model of mammographic imaging with x-ray sources of finite dimensions
    Spyrou, G
    Tzanakos, G
    Nikiforides, G
    Panayiotakis, G
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (06): : 917 - 933
  • [50] Simulation of the X-ray response of scintillator coated silicon CCD:s
    Frojdh, C
    Nelvig, P
    Nilsson, HE
    Petersson, CS
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 516 - 520