Exergoeconomic analysis and optimization of a solar driven dual evaporator vapor compression-absorption cascade refrigeration system using water/CuO nanofluid

被引:68
|
作者
Boyaghchi, Fateme Ahmadi [1 ]
Mahmoodnezhad, Motahare [1 ]
Sabeti, Vajiheh [2 ]
机构
[1] Alzahra Univ, Fac Engn & Technol, Dept Mech Engn, Tehran, Iran
[2] Alzahra Univ, Fac Engn & Technol, Dept Comp Engn, Tehran, Iran
关键词
Thermoeconomic; Solar energy; Cascade refrigeration; Nanoparticle; Optimization; NSGA-II; HEAT-TRANSFER PERFORMANCE; METAL-OXIDE NANOFLUIDS; RANKINE-CYCLE ORC; POWER CHP SYSTEM; 2ND LAW ANALYSIS; THERMOECONOMIC OPTIMIZATION; MULTIOBJECTIVE OPTIMIZATION; GENETIC ALGORITHM; LITHIUM BROMIDE; THERMODYNAMIC ANALYSIS;
D O I
10.1016/j.jclepro.2016.08.125
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, a novel cascade refrigeration system integrated with, flat plate solar collector is modeled and optimized. While LiBr-H2O is applied as fluid pair in cascade absorption section, R134a, R1234ze, R1234yf, R407C and R22 fluids are applied in the vapor compression section and the water/copper oxide (CuO) nanofluid is applied as the heat transfer medium inside the collector subsystem. Nanoparticles volume fraction, mass flow rate of strong solution, low pressure of absorption section, collector tilt angle as well as solar collector area are selected as design parameters while the daily thermal and exergy coefficients of performance and total product cost rate are selected as three objective functions. Non dominated Sort Genetic Algorithm-II (NSGA-II) is individually employed to achieve the final solutions of the system for the best working fluids from the thermodynamic and thermoeconomic viewpoints. The proposed system modeling represents that R134a is the best fluid from the energy and exergy viewpoints with daily energy and exergy coefficients of performance of 9340% and 0.5815%, respectively and R1234ze with the total product cost rate of 7016 $/year is the best working fluid from the exergoeconomic viewpoint. The optimization results indicate that R134a with 2.4% and 2% improvement of the daily energy and exergy coefficients of performance, respectively, relative to the base case needs minimum collector area with amount of 680 m(2) among the other working fluids. In addition, R1234ze with the total product cost rate reduction of 2.4% requires maximum nanoparticles and collector area with values of 0.041 and 702.01 m(2), respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:970 / 985
页数:16
相关论文
共 50 条
  • [41] Optimization of a novel combined cooling, heating and power cycle driven by geothermal and solar energies using the water/CuO (copper oxide) nanofluid
    Boyaghchi, Fateme Ahmadi
    Chavoshi, Mansoure
    Sabeti, Vajiheh
    ENERGY, 2015, 91 : 685 - 699
  • [42] An Exergoeconomic Evaluation of an Innovative Polygeneration System Using a Solar-Driven Rankine Cycle Integrated with the Al-Qayyara Gas Turbine Power Plant and the Absorption Refrigeration Cycle
    Talal, Wadah
    Akroot, Abdulrazzak
    MACHINES, 2024, 12 (02)
  • [43] Exergy analysis of a combined vapor power cycle and boiler flue gas driven double effect water-LiBr absorption refrigeration system
    Talukdar, K.
    Gogoi, T. K.
    ENERGY CONVERSION AND MANAGEMENT, 2016, 108 : 468 - 477
  • [44] THERMODYNAMIC ANALYSIS OF ABSORPTION COOLING SYSTEM WITH LiBr-Al2O3-WATER NANOFLUID USING SOLAR ENERGY
    Kilic, Bayram
    Ipek, Osman
    THERMAL SCIENCE, 2022, 26 (01): : 135 - 146
  • [45] Exergy Analysis of a Solar Vapor Compression Refrigeration System Using R1234ze(E) as an Environmentally Friendly Replacement of R134a
    Triki, Zakaria
    Selloum, Ahmed
    Chiba, Younes
    Tahraoui, Hichem
    Mansour, Dorsaf
    Amrane, Abdeltif
    Zamouche, Meriem
    Kebir, Mohammed
    Zhang, Jie
    FRONTIERS IN HEAT AND MASS TRANSFER, 2024, 22 (04): : 1107 - 1128
  • [46] An innovative hybrid structure of solar PV-driven air separation unit, molten carbonate fuel cell, and absorption–compression refrigeration system (Process development and exergy analysis)
    Ghorbani, Bahram
    Rahnavard, Zahra
    Ahmadi, Mohammad Hossein
    Jouybari, Alireza Khatami
    Energy Reports, 2021, 7 : 8960 - 8972
  • [47] An innovative hybrid structure of solar PV-driven air separation unit, molten carbonate fuel cell, and absorption-compression refrigeration system (Process development and exergy analysis)
    Ghorbani, Bahram
    Rahnavard, Zahra
    Ahmadi, Mohammad Hossein
    Jouybari, Alireza Khatami
    ENERGY REPORTS, 2021, 7 : 8960 - 8972
  • [48] Energetic and Exergetic Analysis of a Solar-Driven Single-Effect Absorption Refrigeration System Using LiBr + LiCl/H2O Solution Mixture
    Aktemur, Cenker
    Ozturk, Ilhan Tekin
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (06):
  • [49] Thermodynamic analysis of a solar-driven vapor compression re-frigeration system using R1234ze for cooling applications in Ghardaïa region (Southern Algeria)
    Selloum, Ahmed
    Triki, Zakaria
    Chiba, Younes
    JOURNAL OF THERMAL ENGINEERING, 2024, 10 (01): : 130 - 141
  • [50] Exergoeconomic, carbon, and water footprint analyses and optimization of a new solar-driven multigeneration system based on supercritical CO2 cycle and solid oxide steam electrolyzer using various phase change materials
    Hadelu, Leila Mohammadi
    Noorpoor, Arshiya
    Boyaghchi, Fateme Ahmadi
    Mirjalili, Seyedali
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2022, 159 : 393 - 421