The hybrid Monte Carlo (MC)/deterministic techniques - Consistent Adjoint Driven Importance Sampling (CADIS) and Forward Weighted CADIS (FW-CADIS) - enable the full 3-D modeling of very large and complicated geometries. The ability of performing global MC calculations for nuclear parameters throughout the entire ITER reactor was demonstrated. The 2 m biological shield (bioshield) reduces the total prompt operational dose by six orders of magnitude. The divertor cryo-pump port results in a peaking factor of 120 in the prompt operational dose rate behind the bioshield of ITER. The equatorial port, plugged by 2 m of shielding, increases the prompt dose rate behind the bioshield by a factor of 47. The peak values of the prompt dose rates at the back surface of the bioshield were 240 mu Sv/hr and 94 mu Sv/hr corresponding to the regions behind the divertor cryo-pump port and the equatorial port, respectively.
引用
收藏
页码:676 / 680
页数:5
相关论文
共 50 条
  • [31] First Monte-Carlo modelling of global beryllium migration in ITER using ERO2.0
    Romazanov, Juri
    Brezinsek, Sebastijan
    Kirschner, Andreas
    Borodin, Dmitriy
    Eksaeva, Anna
    Pitts, Richard A.
    Lisgo, Steven W.
    Anand, Himank
    Veshchev, Evgeny
    Neverov, Vlad S.
    Kukushkin, Alexander B.
    Alekseev, Andrey G.
    Linsmeier, Christian
    CONTRIBUTIONS TO PLASMA PHYSICS, 2020, 60 (5-6)
  • [32] A hybrid dose evaluation method for rapid Monte Carlo-based IMRT optimization
    Siebers, J.
    Kawrakow, I.
    MEDICAL PHYSICS, 2006, 33 (06) : 2207 - 2207
  • [33] HYBRID MONTE-CARLO TECHNIQUES WITH A MINIMAL INTERFACE
    JERMANN, WH
    THOMAS, RC
    CALHOUN, MD
    SIMULATION, 1971, 17 (06) : 225 - +
  • [34] A Hybrid Deterministic/Monte Carlo Method for Solving the k-Eigenvalue Problem with a Comparison to Analog Monte Carlo Solutions
    Willert, J.
    Kelley, C. T.
    Knoll, D. A.
    Park, H.
    JOURNAL OF COMPUTATIONAL AND THEORETICAL TRANSPORT, 2014, 43 (1-7) : 50 - 67
  • [35] Denoising of electron beam Monte Carlo dose distributions using digital filtering techniques
    Deasy, JO
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07): : 1765 - 1779
  • [36] Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC
    Kawrakow, I
    Fippel, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08): : 2163 - 2183
  • [37] DOSE POINT KERNEL SIMULATION FOR MONOENERGETIC ELECTRONS AND RADIONUCLIDES USING MONTE CARLO TECHNIQUES
    Wu, J.
    Liu, Y. L.
    Chang, S. J.
    Chao, M. M.
    Tsai, S. Y.
    Huang, D. E.
    RADIATION PROTECTION DOSIMETRY, 2012, 152 (1-3) : 119 - 124
  • [38] STUDY OF THE SITE DOSE RATE FOR THE ISFSI FACILITY WITH MONTE CARLO AND DETERMINISTIC METHODS
    Wang, Jeng-Ning
    Lu, Chung-Hsin
    Lee, Kuo-Wei
    Lin, Uei-Tyng
    Jiang, Shiang-Huei
    NUCLEAR TECHNOLOGY, 2009, 168 (01) : 101 - 107
  • [39] Dose evaluation in nuclear medicine examination using SIMSET Monte Carlo code
    Chuang, K.
    Lin, H.
    Lin, C.
    Chen, S.
    Jan, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S315 - S315
  • [40] Survey of reliability and availability evaluation of complex networks using Monte Carlo techniques
    Wang, HZ
    Pham, H
    MICROELECTRONICS RELIABILITY, 1997, 37 (02) : 187 - 209