GLOBAL EVALUATION OF PROMPT DOSE RATES IN ITER USING HYBRID MONTE CARLO/DETERMINISTIC TECHNIQUES

被引:5
|
作者
Ibrahim, A. M. [1 ]
Sawan, M. E. [1 ]
Mosher, S. W. [2 ]
Evans, T. M. [2 ]
Peplow, D. E. [2 ]
Wilson, P. P. [1 ]
Wagner, J. C. [2 ]
机构
[1] Univ Wisconsin, Madison, WI 53706 USA
[2] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
关键词
D O I
10.13182/FST11-A12462
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The hybrid Monte Carlo (MC)/deterministic techniques - Consistent Adjoint Driven Importance Sampling (CADIS) and Forward Weighted CADIS (FW-CADIS) - enable the full 3-D modeling of very large and complicated geometries. The ability of performing global MC calculations for nuclear parameters throughout the entire ITER reactor was demonstrated. The 2 m biological shield (bioshield) reduces the total prompt operational dose by six orders of magnitude. The divertor cryo-pump port results in a peaking factor of 120 in the prompt operational dose rate behind the bioshield of ITER. The equatorial port, plugged by 2 m of shielding, increases the prompt dose rate behind the bioshield by a factor of 47. The peak values of the prompt dose rates at the back surface of the bioshield were 240 mu Sv/hr and 94 mu Sv/hr corresponding to the regions behind the divertor cryo-pump port and the equatorial port, respectively.
引用
收藏
页码:676 / 680
页数:5
相关论文
共 50 条
  • [1] ITER NEUTRONICS MODELING USING HYBRID MONTE CARLO/DETERMINISTIC AND CAD-BASED MONTE CARLO METHODS
    Ibrahim, Ahmad M.
    Mosher, Scott W.
    Evans, Thomas M.
    Peplow, Douglas E.
    Sawan, Mohamed E.
    Wilson, Paul P. H.
    Wagner, John C.
    Heltemes, Thad
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 251 - 258
  • [2] Acceleration of calculation of nuclear heating distributions in ITER toroidal field coils using hybrid Monte Carlo/deterministic techniques
    Ibrahim, Ahmad M.
    Polunovskiy, Eduard
    Loughlin, Michael J.
    Grove, Robert E.
    Sawan, Mohamed E.
    FUSION ENGINEERING AND DESIGN, 2016, 109 : 255 - 260
  • [3] Assessment of fusion facility dose rate map using mesh adaptivity enhancements of hybrid Monte Carlo/deterministic techniques
    Ibrahim, Ahmad M.
    Wilson, Paul P.
    Sawan, Mohamed E.
    Mosher, Scott W.
    Peplow, Douglas E.
    Grove, Robert E.
    FUSION ENGINEERING AND DESIGN, 2014, 89 (9-10) : 1875 - 1879
  • [4] Analysis of dpa Rates in the HFIR Reactor Vessel using a Hybrid Monte Carlo/Deterministic Method
    Risner, J. M.
    Blakeman, E. D.
    ISRD 15 - INTERNATIONAL SYMPOSIUM ON REACTOR DOSIMETRY, 2016, 106
  • [5] HYBRID DETERMINISTIC/MONTE CARLO NEUTRONICS
    Willert, Jeffrey
    Kelley, C. T.
    Knoll, D. A.
    Park, H.
    SIAM JOURNAL ON SCIENTIFIC COMPUTING, 2013, 35 (05): : S62 - S83
  • [6] Hybrid Deterministic/Monte Carlo Neutronics using GPU Accelerators
    Willert, Jeff
    Kelley, C. T.
    Knoll, D. A.
    Dong, Han
    Ravishankar, Mahesh
    Sathre, Paul
    Sullivan, Michael
    Taitano, William
    2012 11TH INTERNATIONAL SYMPOSIUM ON DISTRIBUTED COMPUTING AND APPLICATIONS TO BUSINESS, ENGINEERING & SCIENCE (DCABES), 2012, : 43 - 47
  • [7] ENVIRONMENTAL DOSE RATE ASSESSMENT OF ITER USING THE MONTE CARLO METHOD
    Karimian, Alireza
    Beheshti, Amir
    Abdi, Mohammadreza
    Jabbari, Iraj
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2014, 29 (01): : 34 - 39
  • [8] A hybrid Monte Carlo-Deterministic method for global particle transport calculations
    Becker, Troy L.
    Wollaber, Allan B.
    Larsen, Edward W.
    NUCLEAR SCIENCE AND ENGINEERING, 2007, 155 (02) : 155 - 167
  • [9] Comparison of global variance reduction techniques for Monte Carlo radiation transport simulations of ITER
    Davis, Andrew
    Turner, Andrew
    FUSION ENGINEERING AND DESIGN, 2011, 86 (9-11) : 2698 - 2700
  • [10] Evaluation of Monte Carlo codes for dose monitoring using PET and prompt gamma imaging in proton therapy
    Robert, Charlotte
    Dedes, George
    Battistoni, Giuseppe
    Lestand, Loic
    Gueth, Pierre
    Prezado, Yolanda
    Testa, Etienne
    Montarou, Gerard
    Sarrut, David
    Buvat, Irene
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53