Effect of oxidation heat treatment with airborne-particle abrasion on the shear bond strength of ceramic to base metal alloys

被引:3
|
作者
Pagnano, Valeria O. [1 ]
Leal, Monica B. [2 ]
Catirse, Alma B. C. E. B. [1 ]
Curylofo, Patricia A. [1 ]
Silva, Rodrigo F. [3 ]
Macedo, Ana Paula [1 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Dent Mat & Prosthesis, Ribeirao Preto, Brazil
[2] Univ Fed Sergipe, Sch Dent, Aracaju, Brazil
[3] Univ Sao Paulo, Sch Philosophy Sci & Languages Ribeirao Preto, Dept Chem, Ribeirao Preto, Brazil
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2021年 / 126卷 / 06期
关键词
FIXED PARTIAL DENTURES; PORCELAIN; CAST;
D O I
10.1016/j.prosdent.2021.08.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Oxidation heat treatment has been studied to increase the metal-ceramic bond strength. However, information about its use with cobalt-chromium (Co-Cr) alloys is lacking. Purpose. The purpose of this study was to evaluate the effect of oxidation heat treatment and oxidation heat treatment with alumina airborne-particle abrasion on the metal-ceramic bond strength of Co-Cr alloys compared with that of nickel-chromium (Ni-Cr) alloys. Material and methods. In total, 165 metal cylinders (circle divide 5x8 mm) made of 5 base metal alloys were obtained by casting: 2 Ni-Cr (Fit Cast-SB and Fit Cast-V) and 3 Co-Cr alloys (Keragen, StarLoy C, and Remanium 2001). The specimens were divided into groups (n=11): no treatment, oxidation heat treatment, and oxidation heat treatment with airborne-particle abrasion. Oxidation heat treatment was performed starting at 650 degrees C and rising to 980 degrees C. The airborne-particle abrasion was performed with 100 -mm alumina (0.2-MPa pressure, 5 seconds). One specimen had the surface topography and composition evaluated by scanning electron microscopy and energy dispersive X-ray spectrometry. The feldspathic ceramic was applied to the base metal alloy specimens (n=10). Shear tests were performed to obtain the metal-ceramic bond strength (MPa). The failure modes were evaluated. Data were evaluated by 2-way ANOVA and the Tukey post hoc test, Pearson correlation, and Fisher exact tests (alpha=.05). Results. The group without treatment showed the highest roughness. The treatments increased oxygen and chromium levels and decreased nickel, molybdenum, and tungsten levels. Oxidation heat treatment provided an increase in metal-ceramic bond strength (P<.05) for base metal alloys with over 7% molybdenum (Fit Cast-SB, Fit Cast-V, and Remanium 2001). With oxidation heat treatment with airborne particle abrasion, there was improvement only in Fit Cast-SB. No treatment was better for StarLoy C. A weak correlation was found between metal-ceramic bond strength and failure mode (rho=.166; P=.043). The mixed failures were prevalent in Co-Cr alloys (P<.001) and oxidation heat treatment with airborne-particle abrasion (P=.008). Conclusions. The oxidation heat treatment was only beneficial for base metal alloy with a molybdenum content of over 7%. Although the oxidation heat treatment with alumina airborne-particle abrasion was a better treatment for Fit Cast-SB, its use is not justified because it showed no difference for oxidation heat treatment and requires another step in the surface treatment.
引用
收藏
页码:804.e1 / 804.e9
页数:9
相关论文
共 50 条
  • [21] Effect of airborne-particle abrasion of a titanium base abutment on the stability of the bonded interface and retention forces of crowns after artificial aging
    Pitta, Joao
    Burkhardt, Felix
    Mekki, Mustapha
    Fehmer, Vincent
    Mojon, Philippe
    Sailer, Irena
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (02): : 214 - 221
  • [22] Interfacial shear bond strength between different base metal alloys and five low fusing feldspathic ceramic systems
    Sipahi, Cumhur
    Ozcan, Mutlu
    DENTAL MATERIALS JOURNAL, 2012, 31 (03) : 333 - 337
  • [23] Effect of different air-abrasion particles on metal-ceramic bond strength
    Kulunk, Tolga
    Kurt, Murat
    Ural, Cagri
    Kulunk, Safak
    Baba, Seniha
    JOURNAL OF DENTAL SCIENCES, 2011, 6 (03) : 140 - 146
  • [24] THE EFFECTS OF AN AIRBORNE-PARTICLE ABRASION AND SILICA-COATING ON THE BOND STRENGTH BETWEEN GROOVED TITANIUM ALLOY TEMPORARY CYLINDERS AND PROVISIONAL VENEERING MATERIALS
    Wei, Ann Yu-Chieh
    Sharma, Arun B.
    Watanabe, Larry G.
    Finzen, Frederick C.
    JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (03): : 158 - 163
  • [25] Influence of airborne-particle abrasion on mechanical properties and bond strength of carbon/epoxy and glass/bis-GMA fiber-reinforced resin posts
    Soares, Carlos Jose
    Santana, Fernanda Ribeiro
    Pereira, Janaina Carla
    Araujo, Tatiana Santos
    Menezes, Murilo Souza
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (06): : 444 - 454
  • [26] EFFECT OF PARTICLE SIZE ON THE FLEXURAL STRENGTH AND PHASE TRANSFORMATION OF AN AIRBORNE-PARTICLE ABRADED YTTRIA-STABILIZED TETRAGONAL ZIRCONIA POLYCRYSTAL CERAMIC
    Fonseca, Renata Garcia
    Abi-Rached, Filipe de Oliveira
    dos Santos Nunes Reis, Jose Mauricio
    Rambaldi, Elisa
    Baldissara, Paolo
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (06): : 510 - 514
  • [27] EFFECT OF METAL-SURFACE TREATMENT ON CERAMIC BOND STRENGTH
    JOCHEN, DG
    CAPUTO, AA
    MATYAS, J
    JOURNAL OF DENTAL RESEARCH, 1984, 63 : 319 - 319
  • [28] EFFECT OF METAL-SURFACE TREATMENT ON CERAMIC BOND STRENGTH
    JOCHEN, DG
    CAPUTO, AA
    MATYAS, J
    JOURNAL OF PROSTHETIC DENTISTRY, 1986, 55 (02): : 186 - 188
  • [29] Effect of Airborne Particle Abrasion on Microtensile Bond Strength of Total-Etch Adhesives to Human Dentin
    D'Amario, Maurizio
    Piccioni, Chiara
    Di Carlo, Stefano
    De Angelis, Francesca
    Caruso, Silvia
    Capogreco, Mario
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [30] Effect of a DPSS laser on the shear bond strength of ceramic brackets with different base designs
    Park, Mi-Gyoung
    Ro, Jung-Hoon
    Park, Jeong-Kil
    Ko, Ching-Chang
    Kwon, Yong Hoon
    LASERS IN MEDICAL SCIENCE, 2013, 28 (06) : 1461 - 1466