摘要
BACKGROUND: Brain shift and pneumocephalus are major concerns regarding deep brain stimulation (DBS). OBJECTIVE: To report the extent of brain shift in deep structures and pneumocephalus in intraoperative magnetic resonance imaging (MRI). METHODS: Twenty patients underwent bilateral DBS implantation in an MRI suite. Volume of pneumocephalus, duration of procedure, and 6 anatomic landmarks (anterior commissure, posterior commissure, right fornix [RF], left fornix [LF], right putaminal point, and left putaminal point) were measured. RESULTS: Pneumocephalus varied from 0 to 32 mL (median = 0.6 mL). Duration of the procedure was on average 195.5 min (118-268 min) and was not correlated with the amount of pneumocephalus. There was a significant posterior displacement of the anterior commissure (mean = -1.1 mm, P < .001), RF (mean = -0.6 mm, P < .001), LF (mean = -0.7 mm, P < .001), right putaminal point (mean = -0.9 mm, P = .001), and left putaminal point (mean = -1.0 mm, P = .001), but not of the posterior commissure (mean = 0.0 mm, P = .85). Both RF (mean = -.7 mm, P < .001) and LF (mean = -0.5 mm, P < .001) were posteriorly displaced after a right-sided burr hole. There was a correlation between anatomic landmarks displacement and pneumocephalus after 2 burr holes (rho = 0.61, P = .007), but not after 1 burr hole (rho = 0.16, P = .60). CONCLUSION: Better understanding of how pneumocephalus displaces subcortical structures can significantly enhance our intraoperative decision making and overall targeting strategy.
引用
收藏
页码:668 / 674
页数:7
相关论文
共 50 条
  • [31] Preventing Shift from Pneumocephalus During Deep Brain Stimulation Surgery: Don't Give Up the 'Fork in the Brain'
    Martinez-Nunez, Alfonso enrique
    Wong, Joshua k.
    Hilliard, Justin d.
    Foote, Kelly d.
    Okun, Michael s.
    TREMOR AND OTHER HYPERKINETIC MOVEMENTS, 2024, 14
  • [32] Assessment of brain shift related to deep brain stimulation surgery
    Khan, Muhammad Faisal
    Mewes, Klaus
    Gross, Robert E.
    Skrinjar, Oskar
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2008, 86 (01) : 44 - 53
  • [33] Motor and Nonmotor Circuitry Activation Induced by Subthalamic Nucleus Deep Brain Stimulation in Patients With Parkinson Disease: Intraoperative Functional Magnetic Resonance Imaging for Deep Brain Stimulation
    Knight, Emily J.
    Testini, Paola
    Min, Hoon-Ki
    Gibson, William S.
    Gorny, Krzysztof R.
    Favazza, Christopher P.
    Felmlee, Joel P.
    Kim, Inyong
    Welker, Kirk M.
    Clayton, Daniel A.
    Klassen, Bryan T.
    Chang, Su-youne
    Lee, Kendall H.
    MAYO CLINIC PROCEEDINGS, 2015, 90 (06) : 773 - 785
  • [34] Evaluation of Patient Perspectives Toward Awake, Frame-Based Deep-Brain Stimulation Surgery
    Ben-Haim, Sharona
    Falowski, Steven M.
    WORLD NEUROSURGERY, 2018, 111 : E601 - E607
  • [35] Probing responses to deep brain stimulation with functional magnetic resonance imaging
    Loh, Aaron
    Gwun, David
    Chow, Clement T.
    Boutet, Alexandre
    Tasserie, Jordy
    Germann, Jurgen
    Santyr, Brendan
    Elias, Gavin
    Yamamoto, Kazuaki
    Sarica, Can
    Vetkas, Artur
    Zemmar, Ajmal
    Madhavan, Radhika
    Fasano, Alfonso
    Lozano, Andres M.
    BRAIN STIMULATION, 2022, 15 (03) : 683 - 694
  • [36] Successful Deep Brain Stimulation Surgery With Intraoperative Magnetic Resonance Imaging on a Difficult Neuroacanthocytosis Case: Case Report
    Lim, Thien Thien
    Fernandez, Hubert H.
    Cooper, Scott
    Wilson, Kathryn Mary K.
    Machado, Andre G.
    NEUROSURGERY, 2013, 73 (01) : E184 - E187
  • [38] Neurostimulators: Potential for excessive heating of deep brain stimulation electrodes during magnetic resonance imaging
    Rezai, AR
    Finelli, D
    Nyenhuis, JA
    Shellock, FG
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) : 488 - 489
  • [39] ClearPoint versus frame-based MRI-guided and MRI-verified deep brain stimulation
    Zrinzo, Ludvic
    Akram, Harith
    Hariz, Marwan
    JOURNAL OF NEUROSURGERY, 2020, 133 (05) : 1624 - 1625
  • [40] Techniques of Frameless Robot-Assisted Deep Brain Stimulation and Accuracy Compared with the Frame-Based Technique
    Mei, Shanshan
    Yu, Kaijia
    Ren, Zhiwei
    Hu, Yongsheng
    Guo, Song
    Li, Yongjie
    Li, Jianyu
    BRAIN SCIENCES, 2022, 12 (07)