A test-bed for optimizing high-resolution single particle reconstructions

被引:30
|
作者
Stagg, Scott M. [1 ,2 ]
Lander, Gabriel C. [1 ]
Quispe, Joel [1 ]
Voss, Neil R. [1 ]
Cheng, Anchi [1 ]
Bradlow, Henry [1 ]
Bradlow, Steven [3 ]
Carragher, Bridget [1 ]
Potter, Clinton S. [1 ]
机构
[1] Scripps Res Inst, Dept Cell Biol, La Jolla, CA 92037 USA
[2] Florida State Univ, Inst Mol Biophys, Tallahassee, FL 32306 USA
[3] Univ Illinois, Dept Math, Urbana, IL 61801 USA
关键词
single particle reconstruction; TEM; automation; optimization; CryoEM; database;
D O I
10.1016/j.jsb.2008.04.005
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
It is becoming routine for cryoEM single particle reconstructions to result in 3D electron density maps with resolutions of similar to 10 angstrom, but maps with resolutions of 5 angstrom or better are still celebrated events. The electron microscope has a resolving power to better than 2 angstrom, and thus should not be a limiting factor; instead the practical limitations in resolution most likely arise from a combination of specimen preparation methods, data collection parameters, and data analysis procedures. With the aid of a highly automated system for acquiring images, coupled to a relational database to keep track of all processing parameters, we have taken a systematic approach to optimizing parameters affecting the resolution of single particle reconstructions. Using GroEL as a test-bed, we performed a series of 3D reconstructions where we systematically varied the number of particles used in computing the map, the accelerating voltage of the microscope, and the electron dose used to acquire the images. We also investigated methods for excluding unacceptable or "bad" particles from contributing to the final 3D map. Using relatively standard instrumentation (Tecnai F20, 4K x 4K CCD, side entry cold stage) and a completely automated approach, these approaches resulted in a map with a nominal resolution of 5.4 angstrom (FSC0.5) in which secondary structure is clearly discernable and the handedness of some of the alpha-helices in the GroEL structure can be determined. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:29 / 39
页数:11
相关论文
共 50 条
  • [31] A program designed for the High-speed Gearbox test-bed based on LabVIEW
    Wang Fengtao
    He Liang
    Wu Dong
    MECHATRONICS AND APPLIED MECHANICS, PTS 1 AND 2, 2012, 157-158 : 727 - 730
  • [32] HIGH-RESOLUTION MEASUREMENT OF PARTICLE VELOCITIES IN A SPOUTED BED USING LASER-DOPPLER ANEMOMETRY
    BOULOS, MI
    WALDIE, B
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1986, 64 (06): : 939 - 943
  • [33] High speed rotating test-bed with flexible, squeeze film damped support
    Xu, Wanfu
    Wen, Zhijian
    Xu, Lifu
    Liu, Yuchuan
    Shen, Xinmin
    Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 2004, 40 (09): : 144 - 147
  • [34] Combined Virtual and Real Robotic Test-bed for Single Operator Control of Multiple Robots
    Lee, Sam Y. -S.
    Hunt, Shawn
    Cao, Alex
    Pandya, Abhilash
    UNMANNED SYSTEMS TECHNOLOGY XII, 2010, 7692
  • [35] Structure Optimization Design of Drum of High-speed Tire Test-bed
    Li, Shiwu
    Tian, Jingjing
    Yang, Zhifa
    Wang, Haizheng
    Chen, Lu
    MATERIALS PROCESSING TECHNOLOGY, PTS 1-4, 2011, 291-294 : 2306 - 2310
  • [36] Test-bed's Development of the Packed Bed with Both Revolution&Rotation's High Gravity
    Zhang, Chongpeng
    Dong, Zhiqiang
    He, Bianhua
    4TH INTERNATIONAL CONFERENCE ON MANUFACTURING AND INDUSTRIAL TECHNOLOGIES (ICMIT 2017), 2017, 212
  • [37] Optimizing sampling strategies in high-resolution paleoclimate records
    de Winter, Niels J.
    Agterhuis, Tobias
    Ziegler, Martin
    CLIMATE OF THE PAST, 2021, 17 (03) : 1315 - 1340
  • [38] Optimizing the high-resolution manometry (HRM) study protocol
    Patel, A.
    Ding, A.
    Mirza, F.
    Gyawali, C. P.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2015, 27 (02): : 300 - 304
  • [39] HIGH-RESOLUTION HOLOGRAPHIC PARTICLE SIZING SYSTEM
    WITHEROW, WK
    OPTICAL ENGINEERING, 1979, 18 (03) : 249 - 255
  • [40] HIGH-RESOLUTION STUDY OF AN ICOSAHEDRAL PALLADIUM PARTICLE
    PENISSON, JM
    RENOU, A
    EUREM 88, VOLS 1-3: TUTORIALS, INSTRUMENTATION AND TECHNIQUES / PHYSICS AND MATERIALS / BIOLOGY, 1988, 93 : 303 - 304