Commissioning and beam characterization of the first gantry-mounted accelerator pencil beam scanning proton system

被引:41
|
作者
Kang, M. [1 ]
Cessac, Rob [2 ]
Pang, D. [1 ]
机构
[1] Georgetown Univ Hosp, Dept Radiat Med, Washington, DC 20007 USA
[2] Mevion Med Syst Inc, Littleton, MA USA
关键词
adaptive aperture; beam commissioning; compart PBS system; gantry-mounted accelerator; HYPERSCAN; pencil beam scanning; MONTE-CARLO; THERAPY; INTERPLAY; LUNG; DELIVERY; CANCER; MOTION; PATIENT; IMPACT; TUMOR;
D O I
10.1002/mp.13972
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present and discuss beam characteristics and commissioning process of the first gantry-mounted accelerator single-room pencil beam scanning (PBS) proton system. Methods: The Mevion HYPERSCAN employs a design configuration with a synchrocyclotron mounted on the gantry to eliminate the traditional beamline and a nozzle that contains the dosimetry monitoring chambers, the energy modulator [energy selector (ES)], and an adaptive aperture (AA). To characterize the beam, we measured the integrated depth dose (IDD) for 12 energies. from the highest energy of 227 MeV down to 28 MeV with a range difference similar to 2 cm between the adjacent energies, using a large radius Bragg peak chamber; single spot profiles in air at five locations along the beam central axis using radiochromic EBT3 film and cross compared with a scintillation detector; and determined the output using a densely packed spot map. To access the performance of AA, we measured interleaf leakage and the penumbra reduction effect. Monte Carlo simulation using TOPAS was performed to study spot size variation along the beam path, beam divergence, and energy spectrum. Results: This proton system is calibrated to deliver 1 Gy dose at 5 cm depth in water using the highest beam energy by delivering 1 MU/spot to a 10 x 10 cm(2) map with a 2.5 mm spot spacing. The spot size in air at isocenter for a maximum range beam of 227 MeV is 4.1 mm. This system is able to reduce the beam range all the way to the patient surface; the lowest energy beam measured was 28 MeV which has a spot size of 15.7 mm. The beam divergence is 2.4 mrad at 227 MeV and 52.7 mrad for the superficial 28 MeV beam. The binary design of the ES has resulted in shifts of the effective SSD toward the isocenter as the energy is modulated lower. The pristine Bragg peaks have a constant 80%-80% width of 8.4 mm at all energies. The interleaf leakage of the AA is less than 1.5% at the highest energy. The AA reduces field penumbras. For a 10x10 optimized field, the 227 MeV beam penumbra measured at isocenter with a 5 cm air gap went from 6.8 to 4.7 mm and the 28 MeV beam penumbra went from 21.4 to 7.5 mm. Conclusions: The HYPERSCAN proton system has a unique design, which is reflected in the Bragg peak shapes, the variation of spot sizes with energy and the penumbra sharpening effect of the AA. The combination of the ES and AA makes PBS implementation possible without using a beam transport line and supplemental range shifter devices. In commissioning the TPS and designing plans these differences need to be considered. (C) 2020 American Association of Physicists in Medicine
引用
收藏
页码:3496 / 3510
页数:15
相关论文
共 50 条
  • [21] Comparison of multi-institutional Varian ProBeam pencil beam scanning proton beam commissioning data
    Langner, Ulrich W.
    Eley, John G.
    Dong, Lei
    Langen, Katja
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (03): : 96 - 107
  • [22] Beam characteristics of the first clinical 360° rotational single gantry room scanning pencil beam proton treatment system and comparisons against a multi-room system
    Shang, Charles
    Evans, Grant
    Rahman, Mushfiqur
    Lin, Liyong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (09): : 266 - 271
  • [23] Gantry-Mounted Laser-Stripe Scanning System for Face Shape Recovery
    Huang, Sheng-Wen
    Huang, Po-Sen
    Zhang, Jia-Hong
    Hong, Yu-Mei
    Chen, Chia-Yen
    Chang, BaoRong
    INTELLIGENT SYSTEMS AND APPLICATIONS (ICS 2014), 2015, 274 : 1305 - 1314
  • [24] Commissioning a Fixed Field FLASH Pencil Beam Scanning Proton Therapy System in Support of the First In-Human Clinical Trial
    Mascia, A.
    Zhang, Y.
    Lee, E.
    Xiao, Z.
    Speth, J.
    Sertorio, M.
    Abel, E.
    Folkerts, M.
    Lourenco, A.
    Lee, N.
    Subiel, A.
    Romano, F.
    Thomas, R.
    Amos, R.
    Breneman, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [25] Clinical application of a gantry-attachable plastic scintillating plate dosimetry system in pencil beam scanning proton therapy beam monitoring
    Jeong, Seonghoon
    Yoon, Myonggeun
    Chung, Kwangzoo
    Ahn, Sung Hwan
    Lee, Boram
    Seo, Jaehyeon
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 181 - 186
  • [26] POSITIONING ACCURACY OF A GANTRY-MOUNTED RADIOACTIVE TRACKING SYSTEM VERSUS VARIAN TRILOGY CONE BEAM CT
    Dror, A.
    Shchory, T.
    Lifshitz, I.
    Pfeffer, R.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S530 - S531
  • [27] An Automatic Beam Model Commissioning Method for Monte Carlo Simulations in Pencil-Beam Scanning Proton Therapy
    Qin, N.
    Shen, C.
    Tian, Z.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2016, 43 (06) : 3335 - 3335
  • [28] Organ doses from a proton gantry-mounted cone-beam computed tomography system characterized with MCNP6 and GATE
    Ardenfors, Oscar
    Henry, Thomas
    Gudowska, Irena
    Poludniowski, Gavin
    Dasu, Alexandru
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 53 : 56 - 61
  • [29] Investigation on beam width tolerances for proton pencil beam scanning
    Ackermann, B.
    Brons, S.
    Ellerbrock, M.
    Jaekel, O.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S781 - S782
  • [30] Golden beam data for proton pencil-beam scanning
    Clasie, Benjamin
    Depauw, Nicolas
    Fransen, Maurice
    Goma, Carles
    Panahandeh, Hamid Reza
    Seco, Joao
    Flanz, Jacob B.
    Kooy, Hanne M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05): : 1147 - 1158