Colour Doppler sonography of hepatic haemangiomas with arterioportal shunts

被引:16
|
作者
Lim, K. J. [1 ,2 ,3 ]
Kim, K. W. [1 ,2 ]
Jeong, W. K. [1 ,2 ,4 ]
Kim, S. Y. [1 ,2 ,5 ]
Jang, Y. J. [1 ,2 ,6 ]
Yang, S. [7 ]
Lee, J. J. [8 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, Seoul 138736, South Korea
[3] Hallym Univ, Kangdong Sacred Heart Hosp, Coll Med, Dept Radiol, Seoul, South Korea
[4] Hanyang Univ, Guri Hosp, Dept Radiol, Gyonggi Do, South Korea
[5] Seoul Natl Univ, Bundang Hosp, Dept Radiol, Gyeonggi Do, South Korea
[6] Kyungpook Natl Univ Hostpital, Dept Radiol, Taegu, South Korea
[7] Dan Kook Univ, Coll Med, Chungnam, South Korea
[8] Catholic Univ Korea, Dept Digital Media, Gyeonggi Do, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2012年 / 85卷 / 1010期
关键词
FOCAL NODULAR HYPERPLASIA; LIVER; CT; DIAGNOSIS; US;
D O I
10.1259/bjr/96605786
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To determine the frequency of intratumoural flow and peritumoural hepatofugal portal flow using colour Doppler sonography (CDS) on hepatic haemangiomas with arterioportal shunt (APS), and to investigate possible factors that may affect the capability of CDS to depict such findings. Methods: The study included 45 patients (35 men, 10 women; mean age, 56 years) with hepatic haemangiomas with APS on CT or MRI. Locating the tumour on greyscale sonography, the depth, size and echogenicity of the tumour were evaluated. CT or MR images were evaluated for fatty liver. CDS was performed to determine the presence of intratumoural flow and peritumoural hepatofugal portal flow. Differences in frequency of intratumoural flow and peritumoural hepatofugal portal flow according to the depth, size, echogenicity and fatty liver were evaluated by Student's t-test and Fisher's exact test. Results: On CDS, intratumoural flow and peritumoural hepatofugal portal flow were found in 66.7% and 60%, respectively. The tumour depth was the significant variable that affected the capability of CDS to depict such findings. The frequencies of intratumoural flow and peritumoural hepatofugal portal flow were as high as 88% and 80% for shallow (<= 30 mm) lesions, and they were 40% and 35% for deep (>30 mm) lesions (p=0.0012; p=0.0051). Conclusion: CDS can commonly depict intratumoural flow and peritumoural hepatofugal portal flow in patients with hepatic haemangiomas with APS. Therefore, CDS should be routinely performed when an incidental mass is encountered during the screening sonography, especially when the lesion is shallow.
引用
收藏
页码:142 / 146
页数:5
相关论文
共 50 条
  • [41] Transjugular intrahepatic portosystemic shunts:: Improved evaluation with echo-enhanced color Doppler sonography, power Doppler sonography, and spectral duplex sonography
    Fürst, G
    Malms, J
    Heyer, T
    Saleh, A
    Cohnen, M
    Frieling, T
    Weule, J
    Hofer, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (04) : 1047 - 1054
  • [42] Advanced Hepatocellular Carcinoma With Hepatic Arterioportal Shunts: Combination Treatment of Transarterial Chemoembolization With Apatinib
    Sun, Tao
    Ren, Yanqiao
    Kan, Xuefeng
    Chen, Lei
    Zhang, Weihua
    Yang, Fan
    Zheng, Chuansheng
    FRONTIERS IN MOLECULAR BIOSCIENCES, 2020, 7
  • [43] Prevalence, Characteristics, and Fate of Intrahepatic Nontumorous Arterioportal Shunts on MRI in Patients With Hepatic Steatosis
    Wehrli, Natasha E.
    Mussi, Thais C.
    Rosenkrantz, Andrew B.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (04) : 375 - 380
  • [44] Differential diagnosis of neonatal adrenal haemorrhage and congenital neuroblastoma by colour coded Doppler sonography and power Doppler sonography
    Deeg, KH
    Bettendorf, U
    Hofmann, V
    EUROPEAN JOURNAL OF PEDIATRICS, 1998, 157 (04) : 294 - 297
  • [45] Transcranial Doppler Sonography in fulminant hepatic failure
    Abdo, A
    López, O
    Fernández, A
    Santos, J
    Castillo, J
    Castellanos, R
    González, L
    Gómez, F
    Limonta, D
    TRANSPLANTATION PROCEEDINGS, 2003, 35 (05) : 1859 - 1860
  • [46] Significance of duplex/colour Doppler sonography in hepatic arterial chemotherapy for patients with liver metastases from colorectal carcinoma
    Guadagni, S
    Pizzutilli, A
    Mancini, E
    Varrone, A
    Palumbo, G
    Amicucci, G
    Perri, S
    Deraco, M
    Fiorentini, G
    EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 2000, 26 (04): : 381 - 386
  • [47] Detection of blood flow in renal transplants: Conventional colour Doppler sonography versus colour Doppler energy mode
    Preidler, KW
    Riccabona, M
    Szolar, DM
    Kammerhuber, F
    Sorantin, E
    Horina, J
    ULTRASCHALL IN DER MEDIZIN, 1996, 17 (05): : 243 - 246
  • [48] Ultrasound with Doppler evaluation of congenital hepatic vascular shunts
    Apeksha Chaturvedi
    Nina B. Klionsky
    David Saul
    Pediatric Radiology, 2018, 48 : 1658 - 1671
  • [49] Ultrasound with Doppler evaluation of congenital hepatic vascular shunts
    Chaturvedi, Apeksha
    Klionsky, Nina B.
    Saul, David
    PEDIATRIC RADIOLOGY, 2018, 48 (11) : 1658 - 1671
  • [50] CONGENITAL INTRAHEPATIC ARTERIOPORTAL FISTULAS CAUSING NECROTIZING ENTERITIS - DIAGNOSIS VIA DOPPLER SONOGRAPHY AND ANGIOGRAPHY
    HAUSEGGER, KA
    FOTTER, R
    SORANTIN, E
    FLUCKIGER, F
    ULTRASCHALL IN DER MEDIZIN, 1991, 12 (04): : 193 - 196