Reference free nonuniformity correction for mercury cadmium telluride infrared focal plane arrays

被引:0
|
作者
Reddy, P [1 ]
de Jager, G [1 ]
机构
[1] Univ Cape Town, ZA-7700 Rondebosch, South Africa
关键词
Nonuniformity Correction; HgCdTe focal plane arrays; infrared staring cameras; IRFPA signal processing;
D O I
10.1109/COMSIG.1998.736957
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Multi-detector HgCdTe infrared focal plane arrays suffer from inherent low frequency and fixed pattern noise. They are thus limited by their inability to calibrate out individual detector variations. These variations are due to detector to detector dark current (offset) as well as responsivity (gain) variations which completely mask useful thermal signatures in infra-red scenes. Conventional detector compensatory techniques require uniform temperature references. previously special calibration images were used to calibrate systems at start up with off board digital calibration techniques used to correct nonuniformities in the detector array. However, calibration only at start up fails to take into account other operating points as well as any drift In the parameters. This paper describes a real time offset and responsivity (gain) compensation technique for a 3 - 5 mu m HgCdTe infrared focal plane array. The method presented employs a real time scene based correction technique and dispenses with temperature references using the infrared scene itself for calibration. This method allows for the continuous update of the compensation coefficients using statistical assumptions of the scene under view without interrupting the scene with a temperature reference.
引用
收藏
页码:243 / 248
页数:6
相关论文
共 50 条
  • [31] Improvement in adaptive nonuniformity correction method with nonlinear model for infrared focal plane arrays
    Lai Rui
    Yang Yin-Tang
    Li Qing
    Zhou Hui-Xin
    OPTICS COMMUNICATIONS, 2009, 282 (17) : 3444 - 3447
  • [32] Scene based nonuniformity correction based on block ergodicity for infrared focal plane arrays
    Zuo, Chao
    Chen, Qian
    Gu, Guohua
    Sui, Xiubao
    OPTIK, 2012, 123 (09): : 833 - 840
  • [33] High-order-statistics based nonuniformity correction for infrared focal plane arrays
    Research Inst. of Pattern Recognition and Intelligent Control, Xidian Univ., Xi'an 710071, China
    Xi'an Dianzi Keji Daxue Xuebao, 2006, 2 (227-230):
  • [34] Efficient single image stripe nonuniformity correction method for infrared focal plane arrays
    Ren, Jianle
    Chen, Qian
    Qian, Weixian
    Gu, Guohua
    Zuo, Chao
    OPTICAL REVIEW, 2012, 19 (06) : 355 - 357
  • [35] Nonuniformity correction algorithm with efficient pixel offset estimation for infrared focal plane arrays
    Orzanowski, Tomasz
    SPRINGERPLUS, 2016, 5
  • [36] Multiframe registration based adaptive nonuniformity correction algorithm for infrared focal plane arrays
    Ren Jian-Le
    Chen Qian
    Qian Wei-Xian
    Gu Guo-Hua
    Yu Xue-Lian
    Liu Ning
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2014, 33 (02) : 122 - 128
  • [37] Scene-based nonuniformity correction technique for infrared focal-plane arrays
    Liu, Yong-Jin
    Zhu, Hong
    Zhao, Yi-Gong
    APPLIED OPTICS, 2009, 48 (12) : 2364 - 2372
  • [38] Analysis of scene-based techniques for nonuniformity correction of infrared focal plane arrays
    Xu, TH
    Zhao, YG
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2004, 23 (04) : 257 - 261
  • [39] Sequence Arrangement of Wavelet Transform for Nonuniformity Correction in Infrared Focal-Plane Arrays
    Xie Xu-fen
    Zhang Wei
    Zhao Ming
    Zhi Xi-yang
    Wang Fu-gang
    2011 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC IMAGING AND PROCESSING TECHNOLOGY, 2011, 8200
  • [40] APPLICATION OF RECURSIVE MIXED LEAST SQUARES TO NONUNIFORMITY CORRECTION IN INFRARED FOCAL PLANE ARRAYS
    Liu Yong-Jin
    Zhu Hong
    Zhao Yi-Gong
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2009, 28 (06) : 436 - +