Does the type of sagittal split ramus osteotomy influence fixation strength? Evaluation of the mechanical behavior of two types of fixation used in three types of sagittal split ramus osteotomy

被引:0
|
作者
Oliveira, Soraya da Silva [1 ]
Mattos de Carvalho, Pedro Henrique [1 ]
Sverzut, Cassio Edvard [1 ]
Trivellato, Alexandre Elias [1 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto FORP USP, Ave Cafe S-N, BR-14040904 Ribeirao Preto, SP, Brazil
来源
关键词
Sagittal split ramus osteotomy; Rigid internal fixation; In vitro technique; Polyurethanes; BIOMECHANICAL EVALUATION; MANDIBULAR RAMUS; ADVANCEMENT; STABILITY; PATTERNS; PLATES;
D O I
10.1007/s10006-022-01038-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose This study compared the mechanical behavior of two fixation techniques used in three sections representing the sagittal split ramus osteotomy (SSRO) in polyurethane replicas that were divided into groups, according to type of section, and sub-groups according to type of fixation, simulating 11-mm advancement and 6o clockwise mandibular rotation. Methods Loads were applied in two regions, aiming at progressive application and consequent strength value, measured in kilogram-force in displacements of 1, 3, 5, and 7 mm, from the load application tip. Shapiro-Wilk test was performed, followed by two-way analysis of variance (ANOVA-2 way), and Bonferroni's multiple comparison. Results The results showed no statistically significant difference in the type of section and type of fixation used when load was applied to the inter-incisor region. However, when load was applied to the first molar region, statistically significant difference was observed in 1-mm displacement, in which section described by Epker with two modifications showed greater strength, regardless of type of fixation used (p = 0.007). Conclusion In the application of load in the inter-incisor region, there was no statistical difference between the type of osteotomy and the type of fixation used. When applying loads to molars, there was a difference for the type of osteotomy, where the Epker osteotomy with 2 modifications presented greater resistance, regardless of the type of fixation used.
引用
收藏
页码:633 / 639
页数:7
相关论文
共 50 条
  • [41] Clinical Stability of Bespoke Snowman Plates for Fixation following Sagittal Split Ramus Osteotomy of the Mandible
    Byun, Soo-Hwan
    Park, Sang-Yoon
    Yi, Sang-Min
    Park, In-Young
    On, Sung-Woon
    Jeong, Chun-Ki
    Kim, Jong-Cheol
    Yang, Byoung-Eun
    BIOENGINEERING-BASEL, 2023, 10 (08):
  • [42] NEW APPLIANCE FOR REPOSITIONING THE PROXIMAL SEGMENT DURING RIGID FIXATION OF THE SAGITTAL SPLIT RAMUS OSTEOTOMY
    FUJIMURA, N
    NAGURA, H
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1991, 49 (09) : 1026 - 1027
  • [43] Horizontal changes in the condylar head after sagittal split ramus osteotomy with bent plate fixation
    Ueki, Koichiro
    Degerliyurt, Kagan
    Hashiba, Yukari
    Marukawa, Kohei
    Nakagawa, Kiyomasa
    Yamamoto, Etsuhide
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 106 (05): : 656 - 661
  • [44] WEIGHT CHANGES AFTER JAW FIXATION DUE TO SAGITTAL SPLIT RAMUS OSTEOTOMY FOR CORRECTION OF PROGNATHOUS
    HARJU, E
    PERNU, H
    RESUSCITATION, 1984, 12 (03) : 187 - 191
  • [45] Comparison of lower lip hypoesthesia between hybrid fixation and conventional fixation following sagittal split ramus osteotomy
    Ueki, Koichiro
    Moroi, Akinori
    Ishihara, Yuri
    Sotobori, Megumi
    Iguchi, Ran
    Kosaka, Akihiko
    Ikawa, Hiroumi
    Yoshizawa, Kunio
    Marukawa, Kohei
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (08) : 1808 - 1812
  • [46] Morphometric Study of Mandibular Ramus Related to Sagittal Ramus Split Osteotomy and Osteosynthesis
    de Oliveira, Marcelo Vinicius
    de Moraes, Paulo Hemerson
    Olate, Sergio
    Alonso, Maria Beatriz C.
    Aranha Watanabe, Plauto Christopher
    Haiter-Neto, Francisco
    de Albergaria-Barbosa, Jose Ricardo
    JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 (05) : 1484 - 1487
  • [47] Sonographic Evaluation of Bone Formation After Sagittal Split Ramus Osteotomy
    Miura, Kei-ichiro
    Yoshida, Masashi
    Yamaguchi, Kojiro
    Yoshida, Reiko
    Asahina, Izumi
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (02) : 395 - 400
  • [48] Mechanical characteristics of the mandible after bilateral sagittal split Ramus osteotomy: Comparing 2 different fixation techniques
    Chuong, CJ
    Borotikar, B
    Schwartz-Dabney, C
    Sinn, DP
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 63 (01) : 68 - 76
  • [49] Periosteal Reflection on the Medial Approach to the Mandibular Ramus in Sagittal Split Ramus Osteotomy
    Muto, Toshitaka
    JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (06) : 2281 - 2283
  • [50] Evaluation of Bone Formation After Sagittal Split Ramus Osteotomy With Bent Plate Fixation Using Computed Tomography
    Ueki, Koichiro
    Hashiba, Yukari
    Marukawa, Kohei
    Okabe, Katsuhiko
    Nakagawa, Kiyomasa
    Alam, Shamiul
    Yamamoto, Etsuhide
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (05) : 1062 - 1068