Mandibular Bone Structure Analysis Using Cone Beam Computed Tomography vs Primary Implant Stability: An Ex Vivo Study

被引:12
|
作者
Pauwels, Ruben [1 ,2 ]
Sessirisombat, Somchai [3 ]
Panmekiate, Soontra [1 ]
机构
[1] Chulalongkorn Univ, Dept Radiol, Fac Dent, 34 Henri Dunant Rd, Bangkok 10330, Thailand
[2] Katholieke Univ Leuven, Biomed Sci Grp, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[3] Chulalongkorn Univ, Dept Oral & Maxillofacial Surg, Fac Dent, Bangkok, Thailand
关键词
bone quality; computer-assisted image processing; cone beam computed tomography; dental implant; implant stability quotient; insertion torque; DENTAL IMPLANTS; IMAGE; CT; OSTEOPOROSIS; IMPACT;
D O I
10.11607/jomi.6210
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the relationship between mandibular bone structure parameters measured on preimplant cone beam computed tomography (CBCT) images and primary implant stability. Materials and Methods: Twenty-one hemimandibles were scanned on the 3D Accuitomo 170 CBCT. Next, an implant was placed in each hemimandible, after which insertion torque and implant stability quotient (ISQ) measurements were acquired. The following measurements were performed on the preimplant CBCT scans: bone surface, bone volume, fractal dimension, connectivity, trabecular thickness and spacing, and skeleton analysis. Measurements were performed using various regions of interest in the vicinity of the implant site. In addition, cortical thickness was measured. The correlation between bone structure parameters, insertion torque, and ISQ was calculated. Results: The overall correlation was low to medium (vertical bar R vertical bar = 0.002-0.723). For the bone around the entire implant site, the highest correlation with ISQ was found for skeleton analysis and trabecular thickness. The highest overall correlation between bone structure and ISQ was found in the coronal region. For insertion torque, no significant correlation was found for the bone around the entire implant; the highest overall correlation was found in the apical region. The highest number of significant correlations between bone structure and primary implant stability were found for trabecular thickness and fractal dimension. Conclusion: While each of the investigated bone structure parameters can have a predictive value in terms of primary implant stability, they should be measured at specific regions surrounding a planned implant site, and can provide complementary information regarding the local bone quality.
引用
收藏
页码:1257 / +
页数:45
相关论文
共 50 条
  • [31] Jawbone measurements of edentulous sites related to implant planning using magnetic resonance imaging compared to cone beam computed tomography: An ex vivo study
    Fuglsig, Joao Marcus de Carvalho e Silva
    Schropp, Lars
    Hansen, Brian
    Wenzel, Ann
    Spin-Neto, Rubens
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (02) : 179 - 186
  • [32] Labial bone assessment surrounding dental implant using cone-beam computed tomography: an in vitro study
    Naitoh, Munetaka
    Hayashi, Hisashi
    Tsukamoto, Nobutaka
    Ariji, Eiichiro
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (08) : 970 - 974
  • [33] The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
    Noaman, Ali Tareef
    Bede, Salwan Y.
    JOURNAL OF CRANIOFACIAL SURGERY, 2022, 33 (06) : E553 - E557
  • [34] Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography
    Sabban, Hanadi
    Mahdian, Mina
    Dhingra, Ajay
    Lurie, Alan G.
    Tadinada, Aditya
    IMAGING SCIENCE IN DENTISTRY, 2015, 45 (02) : 73 - 80
  • [35] Analysis of mandibular molar anatomy in Taiwanese individuals using cone beam computed tomography
    Shen, Ting-Chun
    Tu, Ming-Gene
    Huang, Heng-Li
    Peng, Shin-Lei
    Hsu, Jui-Ting
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (01) : 419 - 427
  • [36] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Yan Huang
    Jeroen Van Dessel
    Maarten Depypere
    Mostafa EzEldeen
    Alexandru Andrei Iliescu
    Emanuela Dos Santos
    Ivo Lambrichts
    Xin Liang
    Reinhilde Jacobs
    Bone Research, 2014, (02) : 103 - 109
  • [37] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Yan Huang
    Jeroen Van Dessel
    Maarten Depypere
    Mostafa EzEldeen
    Alexandru Andrei Iliescu
    Emanuela Dos Santos
    Ivo Lambrichts
    Xin Liang
    Reinhilde Jacobs
    Bone Research, 2014, 2 (02) : 103 - 109
  • [38] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Huang, Yan
    Van Dessel, Jeroen
    Depypere, Maarten
    EzEldeen, Mostafa
    Iliescu, Alexandru Andrei
    Dos Santos, Emanuela
    Lambrichts, Ivo
    Liang, Xin
    Jacobs, Reinhilde
    BONE RESEARCH, 2014, 2
  • [39] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Yan Huang
    Jeroen Van Dessel
    Maarten Depypere
    Mostafa EzEldeen
    Alexandru Andrei Iliescu
    Emanuela Dos Santos
    Ivo Lambrichts
    Xin Liang
    Reinhilde Jacobs
    Bone Research, 2
  • [40] Assessment of the middle mesial canals of mandibular first molars using cone-beam computed tomography: an in vivo study
    Alroomy, R.
    Elbaz, F.
    Asiri, A.
    Almulhim, B.
    Kumari, M.
    Gunaranjan, T.
    Mashyakhy, M.
    Okazaki, K.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2022, 26 (08) : 2861 - 2866