Investigation of electrolyte measurement in diluted whole blood using spectroscopic and chemometric methods

被引:8
|
作者
Soller, BR [1 ]
Favreau, J [1 ]
Idwasi, PO [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Surg, Worcester, MA 01655 USA
关键词
near-infrared spectroscopy; electrolytes; blood; partial least squares; clinical chemistry;
D O I
10.1366/000370203321535042
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The feasibility of using near-infrared (NIR) spectroscopy in combination with partial least-squares (PLS) regression was explored to measure electrolyte concentration in whole blood samples. Spectra were collected from diluted blood samples containing randomized, clinically relevant concentrations of Na+, K+, and Ca2+. Sodium was also studied in lysed blood. Reference measurements were made from the same samples using a standard clinical chemistry instrument. Partial least squares (PLS) was used to develop calibration models for each ion with acceptable results (Na+, R-2 = 0.86, CVSEP = 9.5 mmol/L; K+, R-2 = 0.54, CVSEP = 1.4 mmol/L; Ca2+, R-2 = 0.56, CVSEP = 0.18 mmol/L). Slightly improved results were obtained using a narrower wavelength region (470-925 nm) where hemoglobin, but not water, absorbed indicating that ionic interaction with hemoglobin is as effective as water in causing measurable spectral variation. Good models were also achieved for sodium in lysed blood, illustrating that cell swelling, which is correlated with sodium concentration, is not required for calibration model development.
引用
收藏
页码:146 / 151
页数:6
相关论文
共 50 条
  • [21] Wearable blood pressure measurement device using cuffless blood pressure measurement methods
    Dohi T.
    Waki K.
    IEEJ Transactions on Sensors and Micromachines, 2016, 136 (09) : 370 - 376
  • [22] COMPARISON OF CYCLOSPORINE-A MEASUREMENT IN WHOLE-BLOOD BY 6 DIFFERENT METHODS
    TJANDRAMAGA, B
    VERBESSELT, R
    SCHARPE, S
    VERKERK, R
    LAMBERT, WE
    VANLIEDEKERKE, B
    DELEENHEER, A
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1990, 28 (01): : 53 - 57
  • [23] Analysis of serum and whole blood using NAA for clinical investigation
    Kovacs, L.
    Zamboni, C. B.
    Oliveira, L. C.
    Salvador, V. L. R.
    Sato, I. M.
    Azevedo, M. R. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 278 (03) : 543 - 545
  • [24] Analysis of serum and whole blood using NAA for clinical investigation
    L. Kovacs
    C. B. Zamboni
    L. C. Oliveira
    V. L. R. Salvador
    I. M. Sato
    M. R. A. Azevedo
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 278 : 543 - 545
  • [25] Investigation of pyrolysis behavior of fenoxycarb using PY-GC-MS assisted with chemometric methods
    Wang, Guoqing
    Hou, Zhenyu
    Sun, Yu'an
    Liu, Yingfan
    Xie, Bing
    Liu, Shaowen
    CHEMIA ANALITYCZNA, 2007, 52 (01): : 141 - 156
  • [26] Spectroscopic blood component measurement by using reduced ranges of absorption spectra
    Arimoto, H
    Yamada, Y
    PHOTON MIGRATION AND DIFFUSE-LIGHT IMAGING, 2003, 5138 : 323 - 330
  • [27] Investigation on the interaction of pyrene with bovine serum albumin using spectroscopic methods
    Xu, Chengbin
    Gu, Jiali
    Ma, Xiping
    Dong, Tian
    Meng, Xuelian
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 125 : 391 - 395
  • [29] Measurement of superoxide dismutase in erythrocytes and whole blood using iodonitrotetrazolium violet
    Haghighi, AZ
    Wei, R
    ANALYTICAL LETTERS, 1998, 31 (06) : 981 - 990
  • [30] Usefulness of fully automated measurement of reticulated platelets using whole blood
    Abe, Y
    Wada, H
    Sakakura, M
    Nishioka, J
    Tomatsu, H
    Hamaguchi, Y
    Oguni, S
    Shiku, H
    Nobori, T
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2005, 11 (03) : 263 - 270