Variation of computed tomographic angiography-based fractional flow reserve after transcatheter aortic valve implantation

被引:4
|
作者
Zhang, Yi [1 ]
Xiong, Tian-Yuan [1 ]
Li, Yi-Ming [1 ]
Huang, Fang-Yang [1 ]
Peng, Yong [1 ]
Li, Qiao [1 ]
Wei, Jia-Fu [1 ]
He, Sen [1 ]
Cao, Kun-Lin [2 ]
Feng, Yuan [1 ]
Xu, Bo [3 ]
Mylotte, Darren [4 ]
Chen, Mao [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Cardiol, 37 Guo Xue Alley, Chengdu 610041, Peoples R China
[2] Keya Med Technol CO Ltd, Shenzhen, Peoples R China
[3] Chinese Acad Med Sci & Peking Union Med Coll, Dept Cardiol, Fuwai Hosp, Natl Ctr Cardiovasc Dis, Beijing, Peoples R China
[4] Univ Hosp Galway, Dept Cardiol, Galway, Ireland
基金
中国国家自然科学基金;
关键词
Transcatheter aortic valve replacement; Coronary artery disease; Computed tomography; Functional flow reserve; STENOSIS; PERFORMANCE; REPLACEMENT; DISEASE; FFR;
D O I
10.1007/s00330-021-08099-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives We sought to identify the impact of transcatheter aortic valve implantation (TAVI) on changes of fractional flow reserve computed tomography (FFRCT) values and the associated clinical impact. Methods A retrospective analysis was done with CT obtained pre-TAVI, prior to hospital discharge and at 1-year follow-up, which provided imaging sources for the calculation of FFRCT values based on an online platform. Results A total of 190 patients were enrolled. Patients with pre-procedural FFRCT value > 0.80 (i.e., negative) and <= 0.80 (i.e., positive) demonstrated a significantly opposite change in the value after TAVI (0.8798 vs. 0.8718, p < 0.001 and 0.7634 vs. 0.8222, p < 0.001, respectively). The history of coronary artery disease (CAD) was identified as an independent predictor for FFRCT changing from negative to positive after TAVI (odds ratio [OR] 2.927, 95% confidence interval [CI] 1.130-7.587, p = 0.027), with lesions more severely stenosed (OR 1.039, 95% CI 1.003-1.076, p = 0.034) and in left anterior descending coronary artery (LAD) (OR 3.939, 95% CI 1.060-14.637, p = 0.041) being prone to change. Conclusions TAVI directly brings improvement in FFRCT values in patients with compromised coronary flow. Patients with a history of CAD, especially with lesions more severely stenosed and in LAD, were under risk of FFRCT changing from negative to positive after TAVI.
引用
收藏
页码:6220 / 6229
页数:10
相关论文
共 50 条
  • [31] Utility of computed tomography in cases of aortic valve stenosis before and after transcatheter aortic valve implantation
    Takaoka, Hiroyuki
    Kitahara, Hideki
    Ota, Joji
    Suzuki-Eguchi, Noriko
    Sasaki, Haruka
    Mori, Naoto
    Takahashi, Manami
    Iida, Yasunori
    Matsuura, Kaoru
    Nakayama, Takashi
    Matsumiya, Goro
    Kobayashi, Yoshio
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2020, 35 (01) : 72 - 84
  • [32] Utility of computed tomography in cases of aortic valve stenosis before and after transcatheter aortic valve implantation
    Hiroyuki Takaoka
    Hideki Kitahara
    Joji Ota
    Noriko Suzuki-Eguchi
    Haruka Sasaki
    Naoto Mori
    Manami Takahashi
    Yasunori Iida
    Kaoru Matsuura
    Takashi Nakayama
    Goro Matsumiya
    Yoshio Kobayashi
    Cardiovascular Intervention and Therapeutics, 2020, 35 : 72 - 84
  • [33] Diagnostic Accuracy of Angiography-Based Vessel Fractional Flow Reserve (vFFR) Virtual Stenting
    Tomaniak, Mariusz
    Neleman, Tara
    Kucuk, Ibrahim
    Masdjedi, Kaneshka
    Zandvoort, Laurens
    Kochman, Janusz
    Den Dekker, Wijnand
    Wilschut, Jeroen
    Diletti, Roberto
    Kardys, Isabella
    Zijlstra, Felix
    Van Mieghem, Nicolas
    Daemen, Joost
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (19) : B124 - B124
  • [34] Diagnostic accuracy of angiography-based vessel fractional flow reserve after chronic coronary total occlusion recanalization
    Scoccia, Alessandra
    Scarparo, Paola
    Neleman, Tara
    Kakar, Hala
    Wilschut, Jeroen
    Den Dekker, Wijnand K.
    Zijlstra, Felix
    Van Mieghem, Nicolas M.
    Daemen, Joost
    Diletti, Roberto
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 100 (06) : 964 - 970
  • [35] Comparison of Aortic Flow Patterns Before and After Transcatheter Aortic Valve Implantation
    F. P. P. Tan
    X. Y. Xu
    R. Torii
    N. B. Wood
    N. Delahunty
    M. Mullen
    N. Moat
    R. Mohiaddin
    Cardiovascular Engineering and Technology, 2012, 3 (1) : 123 - 135
  • [36] Diagnostic accuracy of angiography-based vessel fractional flow reserve after chronic coronary total occlusion recanalization
    Scoccia, A.
    Scarparo, P.
    Neleman, T.
    Wilschut, J.
    Den Dekker, W.
    Zijlstra, F.
    Van Mieghem, N.
    Daemen, J.
    Diletti, R.
    EUROPEAN HEART JOURNAL, 2022, 43 : 1123 - 1123
  • [37] Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
    Leipsic, Jonathon
    Gurvitch, Ronen
    LaBounty, Troy M.
    Min, James K.
    Wood, David
    Johnson, Mark
    Ajlan, Amr M.
    Wijesinghe, Namal
    Webb, John G.
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (04) : 416 - 429
  • [38] Computed tomography to guide transcatheter aortic valve implantation
    Daghem, Marwa
    Weidinger, Florian
    Achenbach, Stephan
    HERZ, 2023, 48 (05) : 359 - 365
  • [39] Cardiac multislice computed tomography after transcatheter aortic valve implantation: Features after "valve-in-valve" implantation for degenerative stented aortic bioprosthesis
    Caudron, Jerome
    Eltchaninoff, Helene
    Godin, Mathieu
    Dacher, Jean-Nicolas
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (03) : 190 - 192
  • [40] Coronary Computed Tomographic Angiography-Derived Fractional Flow Reserve for Therapeutic Decision Making
    Tesche, Christian
    Vliegenthart, Rozemarijn
    Duguay, Taylor M.
    De Cecco, Carlo N.
    Albrecht, Moritz H.
    De Santis, Domenico
    Langenbach, Marcel C.
    Varga-Szemes, Akos
    Jacobs, Brian E.
    Jochheim, David
    Baguet, Moritz
    Bayer, Richard R., II
    Litwin, Sheldon E.
    Hoffmann, Ellen
    Steinberg, Daniel H.
    Schoep, U. Joseph
    AMERICAN JOURNAL OF CARDIOLOGY, 2017, 120 (12): : 2121 - 2127