Generation of arbitrary intensity profiles by combining the scanning beam with dynamic multileaf collimation

被引:29
|
作者
Spirou, SV
Chui, CS
机构
[1] Department of Medical Physics, Mem. Sloan-Kettering Cancer Center, New York, NY 10021
关键词
dynamic collimation; scanning beam; intensity modulation; multileaf collimators;
D O I
10.1118/1.597672
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An algorithm, which combines the scanning beam with dynamic collimation to generate any arbitrary intensity profile, is presented. The desired intensity profile is assumed to be piecewise Linear. The dynamic collimation method used is the ''sliding window.'' The algorithm can be used either for a given scanning beam profile or to simultaneously determine the scanning beam profile and the leaf motions required to generate the desired intensity profile, which minimize the total treatment time. The limitations imposed by the physics of an elementary beam are taken into account. The algorithm is an iterative one, with typical calculation times being of the order of a few milliseconds. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [31] Integration and dosimetric validation of a dynamic collimation system for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Gutierrez, Alonso N.
    Boland, Thibault
    Hill, Patrick M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (06)
  • [32] Autocalibration of Linear Positioners in a Dynamic Collimation System for Pencil Beam Scanning Proton Therapy
    Patwardhan, K.
    Geoghegan, T.
    Flynn, R.
    Hyer, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E877 - E878
  • [33] Beam intensity modulation using tissue compensators or dynamic multileaf collimation ln three-dimensional conformal radiotherapy of primary cancers of the oropharynx and larynx, including the elective neck
    van Dieren, EB
    Nowak, PJCM
    Wijers, OB
    de Koste, JRV
    van der Est, H
    Binnekamp, DP
    Heijmen, BJM
    Levendag, PC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (05): : 1299 - 1309
  • [34] Method for implementing dynamic photon beam intensity modulation using independent jaws and a multileaf collimator
    Yu, C.X.
    Symons, M.J.
    Du, M.N.
    Martinez, A.A.
    Wong, J.W.
    Physics in Medicine and Biology, 1995, 40 (05):
  • [35] An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators
    Ma, LJ
    Boyer, AL
    Xing, L
    Ma, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06): : 1629 - 1643
  • [36] 2ND-HARMONIC GENERATION FOR ARBITRARY PUMP BEAM PROFILES
    AGRAWAL, GP
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1980, 70 (12) : 1582 - 1582
  • [37] ARBITRARY-INTENSITY-PROFILES MEASUREMENT OF LASER-BEAMS BY A SCANNING AND ROTATING SLIT
    SOTO, J
    APPLIED OPTICS, 1993, 32 (35): : 7272 - 7276
  • [38] Beam commissioning of the first compact proton therapy system with spot scanning and dynamic field collimation
    Vilches-Freixas, Gloria
    Unipan, Mirko
    Rinaldi, Ilaria
    Martens, Jonathan
    Roijen, Erik
    Almeida, Isabel P.
    Decabooter, Esther
    Bosmans, Geert
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1107):
  • [39] Tuning, Calibration and Testing of a Dynamic Collimation System Controller for Pencil Beam Scanning Proton Therapy
    Patwardhan, K.
    Geoghegan, T.
    Smith, B.
    Flynn, R.
    Hyer, D.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [40] A METHOD FOR IMPLEMENTING DYNAMIC PHOTON-BEAM INTENSITY MODULATION USING INDEPENDENT JAWS AND A MULTILEAF COLLIMATOR
    YU, CX
    SYMONS, MJ
    DU, MN
    MARTINEZ, AA
    WONG, JW
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05): : 769 - 787