Stable cancellation of x-ray errors in Bayard-Alpert gauges

被引:2
|
作者
Kendall, BRF
Drubetsky, E
机构
[1] Elvac Labs, Bellefonte, PA 16823 USA
[2] Fredericks Co, Televac Div, Huntingdon Valley, PA 19006 USA
关键词
D O I
10.1116/1.581252
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
X-ray induced emission of electrons from the ion collectors of Bayard-Alpert gauges has long been recognized as a cause of falsely high readings at low pressures. Less well known is the existence of a reverse x-ray effect leading to a superimposed, but usually smaller, error signal in the opposite direction. First explained by Redhead and others in the 1960s as being caused by photoemission from the gauge envelope, this phenomenon was immediately recognized as potentially useful in cancelling the forward x-ray effect. Although promising experimental results were obtained with special gauge tubes, these early researchers concluded that the cancellation process was too unstable to be of any practical use. We report the results of an attempt to stabilize the cancellation process by the use of identical materials at the two photoemission sites. Experimental Bayard-Alpert gauge tubes were built with gold coatings on the insides of the gauge envelopes and on the surfaces of the ion collectors. The envelope coatings were operated at approximately 15-25 V below the potential of the ion collector. Stable reduction of the x-ray errors by a factor of more than 20 has been demonstrated. Short-term improvements by a factor of 100 have been achieved. Useful improvements have also been observed in sensitivity and in stability at high pressures. Results of long-term stability tests at pressures in the 10(-10) Torr range are described. (C) 1998 American Vacuum Society.
引用
收藏
页码:1163 / 1168
页数:6
相关论文
共 50 条
  • [41] NEW X-RAY LIMIT MEASUREMENTS FOR EXTRACTOR GAUGES
    WATANABE, F
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 1991, 9 (05): : 2744 - 2746
  • [42] Gamma-ray bursts as X-ray depth gauges of the universe
    Mészáros, P
    Rees, MJ
    ASTROPHYSICAL JOURNAL, 2003, 591 (02): : L91 - L94
  • [43] Comparing industrial gauges based on neutron and X-ray scattering
    Bartle, C. Murray
    Kroger, Chris
    West, John G.
    PHYSICA B-CONDENSED MATTER, 2006, 385-86 (927-929) : 927 - 929
  • [44] The possibility of errors in the x-ray diascopy in neglect of the selective absorption of the x-ray beams
    Regler, F
    PHYSIKALISCHE ZEITSCHRIFT, 1935, 36 : 530 - 535
  • [45] ERRORS IN X-RAY SPECTROSCOPIC ANALYSIS OF PULP
    FAVINSKII, IY
    SMAGUNOVA, AN
    PANKOVA, LM
    LOSEV, NF
    INDUSTRIAL LABORATORY, 1978, 44 (12): : 1684 - 1685
  • [46] SOURCE OF ERRORS IN X-RAY COMPTON POLARIMETER
    ALEXANDROPOULOS, NG
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (04): : 592 - 592
  • [47] BACKGROUND ERRORS IN X-RAY DIFFRACTION PARAMETERS
    MITRA, GB
    MISRA, NK
    BRITISH JOURNAL OF APPLIED PHYSICS, 1966, 17 (10): : 1319 - &
  • [48] Engineering stable perovskite X-ray detectors
    Kostiantyn Sakhatskyi
    Maksym V. Kovalenko
    Light: Science & Applications, 11
  • [49] Engineering stable perovskite X-ray detectors
    Sakhatskyi, Kostiantyn
    Kovalenko, Maksym V.
    Light: Science and Applications, 2022, 11 (01):
  • [50] Engineering stable perovskite X-ray detectors
    Sakhatskyi, Kostiantyn
    Kovalenko, Maksym V.
    LIGHT-SCIENCE & APPLICATIONS, 2022, 11 (01)