A modal analysis of a two-area system with significant wind power penetration

被引:0
|
作者
Sanchez-Gasca, JJ [1 ]
Miller, NW [1 ]
Price, WW [1 ]
机构
[1] GE Energy, Schenectady, NY 12345 USA
关键词
wind turbine generator; wind farm; wind power; small signal stability; inter-area mode; local mode;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the results of an investigation aimed at ascertaining the effect that a sizeable wind farm exerts on the oscillation modes of a two-area, four-generator power system. The modal characteristics of the system, when a wind farm replaces one of the generators, are analyzed.
引用
收藏
页码:1148 / 1152
页数:5
相关论文
共 50 条
  • [41] Loading margin sensitivity analysis in systems with significant wind power generation penetration
    da Costa, Jhonatan Nascimento
    Passos Filho, Joao Alberto
    Henriques, Ricardo Mota
    ELECTRIC POWER SYSTEMS RESEARCH, 2019, 175
  • [42] Sliding Mode Based Load Frequency Control for a Two-area Interconnected Power System
    Guo, Jianping
    Dong, Lili
    INTERNATIONAL JOURNAL OF INTELLIGENT CONTROL AND SYSTEMS, 2015, 20 (01): : 16 - 25
  • [43] Some New Results on the Identification of Two-Area Power System Models with SVC Control
    Chakrabortty, Aranya
    2009 AMERICAN CONTROL CONFERENCE, VOLS 1-9, 2009, : 2116 - 2121
  • [44] Frequency regulation of two-area thermal and photovoltaic power system via flood algorithm
    Ekinci, Serdar
    Izci, Davut
    Turkeri, Cebrail
    Smerat, Aseel
    Ezugwu, Absalom E.
    Abualigah, Laith
    RESULTS IN CONTROL AND OPTIMIZATION, 2025, 18
  • [45] Communication time delay estimation for load frequency control in two-area power system
    Singh, Vijay P.
    Kishor, Nand
    Samuel, Paulson
    AD HOC NETWORKS, 2016, 41 : 69 - 85
  • [46] Generation maintenance scheduling with significant wind power penetration
    Fang, Chen
    Xia, Qing
    Sun, Xin
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (19): : 20 - 24
  • [47] Neural predictive controller of a two-area load frequency control for interconnected power system
    Kassem, Ahmed M.
    AIN SHAMS ENGINEERING JOURNAL, 2010, 1 (01) : 49 - 58
  • [48] A Robust Active Disturbance Rejection Controller Design for LFC in Two-area Power System
    Liu, Fang
    Xu, Zhuang
    Liu, Ling
    Yang, Fang
    Sidorov, Denis
    2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 8858 - 8863
  • [49] Study on the Mechanism of AC Tie-line Power Fluctuation for a Two-area Interconnected Power System
    Zhao, Weiwei
    Xiao, Bin
    Zhang, Zongxin
    Liang, Ping
    2017 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT-EUROPE), 2017,
  • [50] Recurrent ANN based AGC of a Two-Area Power System with DFIG based Wind Turbines Considering Asynchronous Tie-lines
    Sharma, Gulshan
    Niazi, K. R.
    Ibraheem
    2014 INTERNATIONAL CONFERENCE ON ADVANCES IN ENGINEERING AND TECHNOLOGY RESEARCH (ICAETR), 2014,