Outcome analysis of immediately placed, immediately restored implants in the esthetic area: The clinical relevance of different interimplant distances

被引:29
|
作者
Degidi, Marco
Novaes, Arthur Belem, Jr. [1 ]
Nardi, Diego
Piattelli, Adriano [2 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Buccomaxillofacial Surg & Traumatol & Period, Sao Paulo, Brazil
[2] Univ G dAnnunzio, Sch Dent, Chieti, Italy
关键词
dental implants; gingival recession; osseointegration;
D O I
10.1902/jop.2008.070534
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The purpose of this study was to compare and evaluate bone and soft tissue levels between immediately placed, immediately restored implants positioned in the esthetic anterior region with different interimplant distances (IID). Methods: Forty-nine patients requiring multiple implant restorations in the anterior regions received 152 implants, which were restored immediately. Periapical radiographs and digital images of 99 interimplant sites were taken at the regular follow-up examinations at 0, 6, 12, and 24 months after surgery. They were digitally recorded and analyzed. The presence of the interproximal papilla was assessed and compared to the distances between the bone crest and the contact point between the natural teeth and the restoration crowns. Results: Implants with an IID <2 mm seemed to lose less bone laterally. When the IID was <2 mm, vertical crestal bone loss was significantly greater than in the group with IID >4 mm. The percentage of the interproximal papilla presence decreased when the distance between the bone crest and the contact point between the two restoration crowns was >6 mm and when two implants were placed at a distance >= 4 mm. Conclusions: To guarantee a better esthetic result in immediately placed, immediately restored implants, the contact point between the two prosthetic crowns should be placed at 3 to 4 mm, and never >6 mm, from the bone peak. Two adjacent implants should be placed at a distance >2 and <4 mm.
引用
收藏
页码:1056 / 1061
页数:6
相关论文
共 50 条
  • [41] Short-Term Bone Level Observations Associated with Platform Switching in Immediately Placed and Restored Single Maxillary Implants: A Preliminary Report
    Canullo, Luigi
    Goglia, Giuseppe
    Iurlaro, Giorgia
    Iannello, Giuliano
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2009, 22 (03) : 277 - 282
  • [42] Clinical, Radiographic, and Esthetic Evaluation of Immediately Loaded Laser Microtextured Implants Placed into Fresh Extraction Sockets in the Anterior Maxilla: A 2-Year Retrospective Multicentric Study
    Guarnieri, Renzo
    Placella, Roberto
    Testarelli, Luca
    Iorio-Siciliano, Vincenzo
    Grande, Maurizio
    IMPLANT DENTISTRY, 2014, 23 (02) : 144 - 154
  • [44] Soft tissue healing around implants placed immediately after tooth extraction without incision: A clinical report
    Covani, U
    Barone, A
    Cornelini, R
    Crespi, R
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (04) : 549 - 553
  • [45] A prospective, controlled clinical trial evaluating the clinical radiological and aesthetic outcome after 5years of immediately placed implants in sockets exhibiting periapical pathology
    Jung, Ronald E.
    Zaugg, Balthasar
    Philipp, Alexander O. H.
    Truninger, Thomas C.
    Siegenthaler, David W.
    Haemmerle, Christoph H. F.
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (08) : 839 - 846
  • [46] Aesthetic outcome of immediately restored single implants placed in extraction sockets and healed sites of the anterior maxilla: a retrospective study on 103 patients with 3 years of follow-up
    Mangano, Francesco Guido
    Mastrangelo, Paolo
    Luongo, Fabrizia
    Blay, Alberto
    Tunchel, Samy
    Mangano, Carlo
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (03) : 272 - 282
  • [47] Immediately restored single post extractive implants: clinical outcomes of a retrospective analysis with 8-10 years follow-up
    Grandi, T.
    Figliuzzi, M. M.
    Signorini, L.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2022, 36 (02): : 255 - 265
  • [48] Accuracy of immediately placed implants using surgical guides from different 3-dimensional printers: An in vitro study
    Pitman, Jeremy
    Cosyn, Jan
    Christiaens, Veronique
    Younes, Faris
    de Bruyckere, Thomas
    Vervaeke, Stijn
    Glibert, Maarten
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (05) : 922 - 929
  • [49] Interdental Bone Level around Immediately Placed Implants at Maxillary and Mandibular Molar Sites: A Retrospective Radiographic Analysis
    Alasqah, Mohammed
    Alzahrani, Khalid S.
    Gufran, Khalid
    MEDICINA-LITHUANIA, 2023, 59 (10):
  • [50] Peri-implant evaluation of immediately loaded implants placed in esthetic zone in patients with diabetes mellitus type 2: a two-year study
    Aguilar-Salvatierra, Antonio
    Luis Calvo-Guirado, Jose
    Gonzalez-Jaranay, Maximino
    Moreu, Gerardo
    Arcesio Delgado-Ruiz, Rafael
    Gomez-Moreno, Gerardo
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (02) : 156 - 161