PVT type of the two-phase loop mini tube thermosyphon solar water heater

被引:40
|
作者
Ziapour, Behrooz M. [1 ]
Khalili, Mohsen Bagheri [1 ]
机构
[1] Univ Mohaghegh Ardabili, Dept Mech Engn, Ardebil, Iran
关键词
Loop; Photovoltaic; Solar water heater; Two-phase flow; Wickless heat pipe; PHOTOVOLTAIC CELLS; THERMAL SYSTEMS; PERFORMANCE; COLLECTOR; SIMULATION; MODEL;
D O I
10.1016/j.enconman.2016.10.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, the performance study is performed in order to verify the new design of the photovoltaic (PV) panel combined with type of the wickless heat pipe solar water heater. In this enhanced design, each wickless heat pipe is assumed in the shape of the loop mini tube comprised of the flow boiling process inside it. Without considering the PV panel, this design was reported in our prior published work (Ziapour et al., 2016). Here, the performance of the proposed passive PVT solar collector is numerically performed using EES software. The solar cell packing factor (i.e. fraction of the absorber plate area which is covered by the solar cells)is important parameter for designing a PVT system. The simulation results show that the thermal efficiency of the passive PVT solar system increases with increase of the solar cells packing factor. Through the simulation results it is found that the optimal numbers of the wickless heat pipes may be five loops. By selecting the five loops, the maximum value of the tank water temperature is obtained near to 72 degrees C in the evening. Also the maximum values of eta(th) and eta(pv) are found as 70% and 80% at noon time, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:54 / 61
页数:8
相关论文
共 50 条
  • [21] HEAT TRANSFER PERFORMANCE OF A PULSATED TWO-PHASE LOOP THERMOSYPHON
    Ashraful, Islam Md.
    Ashiqur, Rahman Md.
    Mohammed, Alam
    IMECE 2008: HEAT TRANSFER, FLUID FLOWS, AND THERMAL SYSTEMS, VOL 10, PTS A-C, 2009, : 1411 - 1419
  • [22] Two-Phase Closed-Loop Thermosyphon for Electronic Cooling
    Chang, C. -C.
    Kuo, S. -C.
    Ke, M. -T.
    Chen, S. -L.
    EXPERIMENTAL HEAT TRANSFER, 2010, 23 (02) : 144 - 156
  • [23] An analysis of two-phase flow stability in a thermosyphon with tube separator
    Lin, LC
    Faghri, A
    APPLIED THERMAL ENGINEERING, 1998, 18 (06) : 441 - 455
  • [24] Analysis of two-phase flow stability in a thermosyphon with tube separator
    Univ of Connecticut, Storrs, United States
    Appl Therm Eng, 6 (441-455):
  • [25] Transient characteristics of a two-phase thermosyphon loop for multichip module
    Nam, SS
    Choi, SB
    Kim, JH
    Kwak, HY
    ETRI JOURNAL, 1998, 20 (03) : 284 - 300
  • [26] Heat transfer in the evaporator of an advanced two-phase thermosyphon loop
    Khodabandeh, R
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (02): : 190 - 202
  • [27] Optimal design for a thermosyphon solar water heater
    Shariah, A
    Shalabi, B
    RENEWABLE ENERGY, 1997, 11 (03) : 351 - 361
  • [28] Validated mathematical models of a solar water heater system with thermosyphon evacuated tube collectors
    Wannagosit, C.
    Sakulchangsatjatai, P.
    Kammuang-lue, N.
    Terdtoon, P.
    CASE STUDIES IN THERMAL ENGINEERING, 2018, 12 : 528 - 536
  • [29] Application of a two-phase thermosyphon loop with minichannels and a minipump in computer cooling
    Bielinski, Henryk
    Mikielewicz, Jaroslaw
    ARCHIVES OF THERMODYNAMICS, 2016, 37 (01) : 3 - 16
  • [30] Experimental study on the performance characteristics of an enhanced two-phase loop thermosyphon
    Behrooz M. Ziapour
    Majid Baygan
    Ali Mohammadnia
    Heat and Mass Transfer, 2015, 51 : 1487 - 1492