PVT type of the two-phase loop mini tube thermosyphon solar water heater

被引:40
|
作者
Ziapour, Behrooz M. [1 ]
Khalili, Mohsen Bagheri [1 ]
机构
[1] Univ Mohaghegh Ardabili, Dept Mech Engn, Ardebil, Iran
关键词
Loop; Photovoltaic; Solar water heater; Two-phase flow; Wickless heat pipe; PHOTOVOLTAIC CELLS; THERMAL SYSTEMS; PERFORMANCE; COLLECTOR; SIMULATION; MODEL;
D O I
10.1016/j.enconman.2016.10.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, the performance study is performed in order to verify the new design of the photovoltaic (PV) panel combined with type of the wickless heat pipe solar water heater. In this enhanced design, each wickless heat pipe is assumed in the shape of the loop mini tube comprised of the flow boiling process inside it. Without considering the PV panel, this design was reported in our prior published work (Ziapour et al., 2016). Here, the performance of the proposed passive PVT solar collector is numerically performed using EES software. The solar cell packing factor (i.e. fraction of the absorber plate area which is covered by the solar cells)is important parameter for designing a PVT system. The simulation results show that the thermal efficiency of the passive PVT solar system increases with increase of the solar cells packing factor. Through the simulation results it is found that the optimal numbers of the wickless heat pipes may be five loops. By selecting the five loops, the maximum value of the tank water temperature is obtained near to 72 degrees C in the evening. Also the maximum values of eta(th) and eta(pv) are found as 70% and 80% at noon time, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:54 / 61
页数:8
相关论文
共 50 条
  • [1] Theoretical and experimental investigations of a two-phase thermosyphon solar water heater
    Chien, C. C.
    Kung, C. K.
    Chang, C. C.
    Lee, W. S.
    Jwo, C. S.
    Chen, S. L.
    ENERGY, 2011, 36 (01) : 415 - 423
  • [2] Experimental investigation of a two-phase closed thermosyphon solar water heater
    Esen, M
    Esen, H
    SOLAR ENERGY, 2005, 79 (05) : 459 - 468
  • [3] Latent heat storage in a two-phase thermosyphon solar water heater
    Lee, WS
    Chen, BR
    Chen, SL
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (01): : 69 - 76
  • [4] Long-term thermal performance of a two-phase thermosyphon solar water heater
    Chen, Bo-Ren
    Chang, Yu-Wei
    Lee, Wen-Shing
    Chen, Sih-Li
    SOLAR ENERGY, 2009, 83 (07) : 1048 - 1055
  • [5] An insert-type two-phase closed loop thermosyphon for split-type solar water heaters
    Li, Ji
    Lin, Feng
    Niu, Gengwen
    APPLIED THERMAL ENGINEERING, 2014, 70 (01) : 441 - 450
  • [6] Numerical investigation on effect of riser diameter and inclination on system parameters in a two-phase closed loop thermosyphon solar water heater
    Aung, Nay Zar
    Li, Songjing
    ENERGY CONVERSION AND MANAGEMENT, 2013, 75 : 25 - 35
  • [7] Two-Phase Closed-Loop Thermosyphon Solar Water Heater with Porous Wick Structure: Performance and Start-Up Time
    Huang, Chien
    Lin, Wei-Keng
    Wang, Sung-Ren
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2017, 42 (11) : 4885 - 4894
  • [8] Two-Phase Closed-Loop Thermosyphon Solar Water Heater with Porous Wick Structure: Performance and Start-Up Time
    Chien Huang
    Wei-Keng Lin
    Sung-Ren Wang
    Arabian Journal for Science and Engineering, 2017, 42 : 4885 - 4894
  • [9] Instability of a two-phase loop thermosyphon
    Seok-Ho Rhi
    KSME International Journal, 2002, 16 : 1019 - 1028
  • [10] Instability of a two-phase loop thermosyphon
    Rhi, SH
    KSME INTERNATIONAL JOURNAL, 2002, 16 (07): : 1019 - 1028