Simultaneous voltammetric detection of ascorbic acid, dopamine and uric acid using a pyrolytic graphite electrode modified into dopamine solution

被引:159
|
作者
da Silva, Robson P. [1 ]
Lima, Antonio William O. [1 ]
Serrano, Silvia H. P. [1 ]
机构
[1] Univ Sao Paulo, Inst Chem, BR-05513970 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
pyrolytic graphite modified; electrode; uric and ascorbic acids; dopamine; biological fluids; differential pulse voltammetry;
D O I
10.1016/j.aca.2008.02.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pyrolytic graphite electrodes (PGE) were modified into dopamine solutions using phosphate buffer solutions, pH 10 and 6.5, as supporting electrolyte. The modification process involved a previous anodization of the working electrode at +1. 5 V into 0. 1 mol-L-1 NaOH followed by other anodization step, in the same experimental conditions, into dopamine (DA) solutions. pH of the supporting electrolyte performed an important role in the production of a superficial melanin polymeric film, which permitted the simultaneous detection of ascorbic acid (AA), (DA) and uric acid (UA), Delta EAA-DA = 222 mV-, Delta EAA-UA = 360 mV and Delta EDA-UA=138mV, avoiding the superficial poisoning effects. The calculated detection limits were: 1.4 x 10(-6) mol L-1 for uric acid, 1.3x10-(5) molL(-1) for ascorbic acid and 1.1 X 10(-7) mol L-1 for dopamine, with sensitivities of (7.7 +/- 0.5), (0.061 +/- 0.001) and (9.5 +/- 0.05)A mol(-1) cm(-2), respectively, with no mutual interference. Uric acid was determined in urine, blood and serum human samples after dilution in phosphate buffer and no additional sample pre-treatment was necessary. The concentration of uric acid in urine was higher than the values found in blood and serum and the recovery tests (92-102%) indicated that no matrix effects were observed. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 50 条
  • [21] Simultaneous determination of ascorbic acid and dopamine in the presence of uric acid on ruthenium oxide modified electrode
    Shakkthivel, Piraman
    Chen, Shen-Ming
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (08): : 1680 - 1687
  • [22] Simultaneous determination of ascorbic acid, dopamine, uric acid and xanthine using a nanostructured polymer film modified electrode
    Kalimuthu, Palraj
    John, S. Abraham
    TALANTA, 2010, 80 (05) : 1686 - 1691
  • [23] Carbon nanofiber modified with reduced graphite oxide for detection of ascorbic acid, dopamine, and uric acid
    Aryal, Krishna Prasad
    Jeong, Hae Kyung
    CHEMICAL PHYSICS LETTERS, 2020, 739
  • [24] Polystyrene sulphonate wrapped multiwalled carbon nanotubes modified graphite electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
    Kumar, Simson Prasanna
    Manjunatha, Revanasiddappa
    Venkatesha, Thimmappa Venkatarangaiah
    Suresh, Gurukar Shivappa
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (04) : 299 - 306
  • [25] Polystyrene sulphonate wrapped multiwalled carbon nanotubes modified graphite electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
    Simson Prasanna Kumar
    Revanasiddappa Manjunatha
    Thimmappa Venkatarangaiah Venkatesha
    Gurukar Shivappa Suresh
    Russian Journal of Electrochemistry, 2013, 49 : 299 - 306
  • [26] SIMULTANEOUS ELECTROCHEMICAL DETECTION OF ASCORBIC ACID, DOPAMINE, AND URIC ACID AT MAGNETIC NANOPARTICLES/REDUCED GRAPHENE OXIDE MODIFIED ELECTRODE
    Rosli, Azleen Rashidah Mohd
    Yusoff, Farhanini
    Loh, Saw Hong
    Yusoff, Hanis Mohd
    Jamil, Muhammad Mahadi Abdul
    Shamsudin, Shazrul Hasry
    JURNAL TEKNOLOGI-SCIENCES & ENGINEERING, 2021, 83 (03): : 85 - 92
  • [27] Ultrasensitive simultaneous detection of ascorbic acid, dopamine, uric acid and acetaminophen on a graphitized porous carbon-modified electrode
    Duraisamy, Velu
    Sudha, Velayutham
    Annadurai, Kuppusamy
    Senthil Kumar, Sakkarapalayam Murugesan
    Thangamuthu, Rangasamy
    NEW JOURNAL OF CHEMISTRY, 2021, 45 (04) : 1863 - 1875
  • [28] Voltammetric Detection of Dopamine in Presence of Ascorbic Acid and Uric Acid at Poly (Xylenol Orange) Film-Coated Graphite Pencil Electrode
    Chandra, Umesh
    Swamy, B. E. Kumara
    Gilbert, Ongera
    Sherigara, B. S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2011, 2011
  • [29] Voltammetric studies of an oracet blue modified glassy carbon electrode and its application for the simultaneous determination of dopamine, ascorbic acid and uric acid
    Zare, HR
    Rajabzadeh, N
    Nasirizadeh, N
    Mazloum-Ardakani, M
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 589 (01) : 60 - 69
  • [30] Simultaneous voltammetric measurement of ascorbic acid and dopamine on poly(caffeic acid)-modified glassy carbon electrode
    Li, Nian Bing
    Ren, Wang
    Luo, Hong Qun
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2008, 12 (06) : 693 - 699