BENEFIT OF INTRAOPERATIVE OPTICAL COHERENCE TOMOGRAPHY FOR VITREOMACULAR SURGERY IN HIGHLY MYOPIC EYES

被引:17
|
作者
Bruyere, Elsa [1 ]
Philippakis, Elise [1 ]
Dupas, Benedicte [1 ]
Nguyen-Kim, Pauline [1 ]
Tadayoni, Ramin [1 ]
Couturier, Aude [1 ]
机构
[1] Univ Paris 07, Hop Lariboisiere, AP HP, Dept Ophthalmol,Sorbonne Paris Cite, Paris, France
关键词
high myopia; intraoperative optical coherence tomography; myopic foveoschisis; myopic macular hole; myopic traction maculopathy; myopic vitreoretinal diseases; vitreoretinal surgery; INTERNAL LIMITING MEMBRANE; MACULAR HOLE; RETINAL-DETACHMENT; FLAP TECHNIQUE; VITRECTOMY; HEMORRHAGE; DYNAMICS; REMOVAL; PIONEER; UTILITY;
D O I
10.1097/IAE.0000000000001827
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report the feasibility and information provided by intraoperative optical coherence tomography (iOCT) during vitreomacular surgery in highly myopic eyes. Methods: Retrospective observational case series on consecutive highly myopic eyes that underwent vitreomacular surgery with iOCT for epiretinal membrane (ERM), macular hole, and myopic foveoschisis. The main outcome was the qualitative and quantitative assessment of retinal changes: detection of persistent epiretinal structures, new openings, central macular thickness, and macular hole diameters after each step of the surgical procedure. Quantitative measurements (in pixels) were manually obtained on iOCT video screen captures. Results: Twenty-two eyes were included: six ERMs, 10 macular holes, and 6 with myopic foveoschisis. An unsuspected postpeeling macular opening was detected by iOCT in 2/22 eyes. Intraoperative optical coherence tomography also allowed for detecting the presence of residual fragments of the vitreous cortex in 6/12 eyes after surgically induced posterior vitreous detachment. Intraoperative optical coherence tomography detected residual fragments of the internal limiting membrane in 5/21 eyes after internal limiting membrane peeling, and residual fragments of ERM in 3/15 eyes with ERM. Quantitative analysis did not find any significant change in central macular thickness and macular hole diameters before and after ERM and internal limiting membrane peeling. Conclusion: In highly myopic eyes, iOCT could help assess undetected macular openings and otherwise posterior vitreous status and epiretinal structure peeling.
引用
收藏
页码:2035 / 2044
页数:10
相关论文
共 50 条
  • [31] Analysis of Fundus Shape in Highly Myopic Eyes by Using Curvature Maps Constructed from Optical Coherence Tomography
    Miyake, Masahiro
    Yamashiro, Kenji
    Akagi-Kurashige, Yumiko
    Oishi, Akio
    Tsujikawa, Akitaka
    Hangai, Masanori
    Yoshimura, Nagahisa
    PLOS ONE, 2014, 9 (09):
  • [32] PERIPAPILLARY ARTERIAL RING OF ZINN-HALLER IN HIGHLY MYOPIC EYES AS DETECTED BY OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY
    Ishida, Tomoka
    Jonas, Jost B.
    Ishii, Minami
    Shinohara, Kosei
    Ikegaya, Yoriko
    Ohno-Matsui, Kyoko
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (02): : 299 - 304
  • [33] Morphologic features of iris in highly myopic eyes based on a novel swept-source optical coherence tomography
    Kang, Ching
    Meng, Jiaqi
    Wang, Lan
    Chen, Chao
    Chen, Yuxi
    He, Wenwen
    Zhang, Keke
    Lu, Yi
    Fang, Yanwen
    Zhu, Xiangjia
    EYE, 2024, 38 (18) : 3443 - 3449
  • [34] Intraoperative assessment of retinal morphological changes using microscope-integrated optical coherence tomography during vitreomacular surgery
    Kim, Pauline Nguyen
    Couturier, Aude
    Dupas, Benedicte Marie
    Tadayoni, Ramin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [35] Retinal thickness measurement in myopic eyes using optical coherence tomography.
    Hoh, ST
    Aung, T
    Seah, SKL
    Lim, WK
    Wu, HM
    Lee, L
    Chew, SJ
    Foster, PJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S297 - S297
  • [36] Choroidal Thickness Measurement in Myopic Eyes by Enhanced Depth Optical Coherence Tomography
    Ho, Mary
    Liu, David T. L.
    Chan, Vesta C. K.
    Lam, Dennis S. C.
    OPHTHALMOLOGY, 2013, 120 (09) : 1909 - 1914
  • [37] Intraoperative optical coherence tomography angiography for intraocular surgery
    Cheng, Dan
    Zhang, Ziyi
    Qiao, Yilin
    Ye, Yufeng
    Zhu, Xueying
    Ruan, Kaiming
    Shen, Meixiao
    Liu, Kaiyuan
    Tao, Jiwei
    Chen, Yiqi
    Shen, Lijun
    Li, Peng
    FRONTIERS IN PHYSICS, 2023, 11
  • [38] Intraoperative optical coherence tomography in anterior segment surgery
    Titiyal, Jeewan S.
    Kaur, Manpreet
    Nair, Sridevi
    Sharma, Namrata
    SURVEY OF OPHTHALMOLOGY, 2021, 66 (02) : 308 - 326
  • [39] Retinal topography of myopic eyes: A spectral domain optical coherence tomography study
    Kim, Seong-Woo
    Oh, Jaeryung
    Oh, In Kyung
    Yun, Cheolmin
    Huh, Kuhl
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [40] Diagnostic Accuracy of Optical Coherence Tomography and Scanning Laser Tomography for Identifying Glaucoma in Myopic Eyes
    Malik, Rizwan
    Belliveau, Anne C.
    Sharpe, Glen P.
    Shuba, Lesya M.
    Chauhan, Balwantray C.
    Nicolela, Marcelo T.
    OPHTHALMOLOGY, 2016, 123 (06) : 1181 - 1189