The diagnostic value of D-dimer in acute aortic dissection: a meta-analysis

被引:39
|
作者
Yao, Jian
Bai, Tao
Yang, Bo
Sun, Lizhong [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiovasc Surg, 2 Anzhen Rd, Beijing 100029, Peoples R China
关键词
D-dimer; Acute aortic dissection; Meta-analysis; Diagnostic value; C-REACTIVE PROTEIN; ACUTE PULMONARY-EMBOLISM; BIOMARKERS; SERUM; RATIO; MORTALITY; OUTCOMES; PREDICT;
D O I
10.1186/s13019-021-01726-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective This study aims to evaluate the diagnostic value of D-dimer for acute aortic dissection (AAD) by the method of meta-analysis. Methods PubMed, Cochrane Library, Web of Science, Embase, China National Knowledge Infrastructure (CNKI), and Wanfang databases from the establishment of the databases to December 2020 were systematically searched, and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) system was used to evaluate the quality of the literature. STATA 15.0 software was applied to calculate the pooled sensitivity, specificity, diagnostic odds ratio (DOR), positive likelihood ratio (+LR), negative likelihood ratio (-LR) to draw summary receiver operating characteristics (SROC) curve and calculate the area under the curve (AUC). Meta-regression and subgroup analyses were used to explore the source of heterogeneity. Results A total of 16 clinical studies were enrolled in this study, including 1135 patients. The results of the meta-analysis showed that the pooled sensitivity was 0.96 (95% CI 0.91-0.98), the pooled specificity was 0.70 (95% CI 0.57-0.81), and the pooled DOR was 56.57 (95% CI 25.11-127.44), the pooled +LR was 3.25 (95% CI 2.18-4.85), the pooled -LR was 0.06 (95% CI 0.03-0.12), and the AUC was 0.94 (95% CI 0.91-0.95). Meta-regression and subgroup analysis results showed that publication year, sample size and cutoff value might be sources of heterogeneity. When the concentration of D-dimer was less than or equal to 500 ng/ml, the sensitivity significantly increased. Conclusion D-dimer has an excellent diagnostic value for AAD. It is a useful tool for detecting suspected AAD because of the excellent pooled sensitivity. D-dimer <= 500 ng/ml increases the potential to identify the suspected patients with AAD.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] The diagnostic value of D-dimer in acute aortic dissection: a meta-analysis
    Jian Yao
    Tao Bai
    Bo Yang
    Lizhong Sun
    Journal of Cardiothoracic Surgery, 16
  • [2] Diagnostic value of circulating D-Dimer in acute aortic dissection
    Ohlmann, P.
    Faure, A.
    Morel, O.
    Petit, H.
    Kabbaj, H.
    Roul, G.
    Eisenmann, B.
    Bareiss, P.
    EUROPEAN HEART JOURNAL, 2005, 26 : 188 - 188
  • [3] Meta-Analysis of Usefulness of D-Dimer to Diagnose Acute Aortic Dissection
    Shimony, Avi
    Filion, Kristian B.
    Mottillo, Salvatore
    Dourian, Tara
    Eisenberg, Mark J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (08): : 1227 - 1234
  • [4] D-dimer as a Biomarker for Acute Aortic Dissection A Systematic Review and Meta-analysis
    Cui, Jia-sen
    Jing, Zai-ping
    Zhuang, Shun-jiu
    Qi, Shao-hong
    Li, Li
    Zhou, Jun-wen
    Zhang, Wang
    Zhao, Yun
    Qi, Ning
    Yin, Yang-jun
    MEDICINE, 2015, 94 (04)
  • [5] VALUE OF D-DIMER FOR DETECTION OF ACUTE AORTIC DISSECTION
    Zheng Ziyu
    Ye Zi
    Ye Jialin
    Wang Weiping
    Zhan Hong
    HEART, 2012, 98 : E268 - E268
  • [6] Value of D-dimer testing in acute aortic dissection
    Weber, T
    Auer, J
    Eber, B
    CIRCULATION, 2004, 109 (03) : E24 - E24
  • [7] Diagnostic accuracy of D-dimer for acute aortic syndromes: systematic review and meta-analysis
    Odai, Kaelan Gobeil
    Weill, Sacha
    Goulden, Robert
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2025, 27 (03) : 176 - 177
  • [8] Diagnostic Accuracy of D-Dimer for Acute Aortic Syndromes: Systematic Review and Meta-Analysis
    Essat, Munira
    Goodacre, Steve
    Pandor, Abdullah
    Ren, Sa
    Ren, Shijie
    Clowes, Mark
    ANNALS OF EMERGENCY MEDICINE, 2024, 84 (04) : 409 - 421
  • [9] Serum D-dimer is a sensitive test for the detection of acute aortic dissection: A pooled meta-analysis
    Marill, Keith A.
    JOURNAL OF EMERGENCY MEDICINE, 2008, 34 (04): : 367 - 376
  • [10] THE VALUE OF D-DIMER IN ACUTE AORTIC DISSECTION: THE EXPERIENCE OF CHINA
    Li, W.
    Fan, X.
    Xu, J.
    Zhang, W.
    Wang, X.
    Sun, K.
    Hui, R.
    ATHEROSCLEROSIS SUPPLEMENTS, 2010, 11 (02) : 197 - 197