Biomechanical properties of decellularized porcine pulmonary valve conduits

被引:22
|
作者
Seebacher, Gernot [1 ]
Grasl, Christian [2 ]
Stoiber, Martin [2 ]
Rieder, Erwin [3 ]
Kasimir, Marie-Theres [1 ]
Dunkler, Daniela [4 ]
Simon, Paul [1 ]
Weigel, Guenter [1 ]
Schima, Heinrich [5 ]
机构
[1] Med Univ Vienna, Dept Cardiothorac Surg, Vienna, Austria
[2] Med Univ Vienna, Inst Biomed Engn & Phys, Vienna, Austria
[3] Med Univ Vienna, Dept Gen Surg, Vienna, Austria
[4] Med Univ Vienna, Core Unit Med Stat & Informat, Vienna, Austria
[5] Med Univ Vienna, Ludwig Boltzmann Cluster Cardiovasc Res, Vienna, Austria
关键词
tissue engineering; heart valve; biomechanical testing;
D O I
10.1111/j.1525-1594.2007.00452.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tissue-engineered heart valves constructed from a xenogeneic or allogeneic decellularized matrix might overcome the disadvantages of current heart valve substitutes. One major necessity besides effective decellularization is to preserve the biomechanical properties of the valve. Native and decellularized porcine pulmonary heart valve conduits (PPVCs) (with [n = 10] or without [n = 10] cryopreservation) were compared to cryopreserved human pulmonary valve conduits (n = 7). Samples of the conduit were measured for wall thickness and underwent tensile tests. Elongation measurement was performed with a video extensometer. Decellularized PPVC showed a higher failure force both in longitudinal (+73%; P < 0.01) and transverse (+66%; P < 0.001) direction compared to human homografts. Failure force of the tissue after cryopreservation was still higher in the porcine group (longitudinal: +106%, P < 0.01; transverse: +58%, P < 0.001). In comparison to human homografts, both decellularized and decellularized cryopreserved porcine conduits showed a higher extensibility in longitudinal (decellularized: +61%, P < 0.001; decellularized + cryopreserved: +51%, P < 0.01) and transverse (decellularized: +126%, P < 0.001; decellularized + cryopreserved: +118%, P < 0.001) direction. Again, cryopreservation did not influence the biomechanical properties of the decellularized porcine matrix.
引用
收藏
页码:28 / 35
页数:8
相关论文
共 50 条
  • [31] A riboflavin-ultraviolet light A-crosslinked decellularized heart valve for improved biomechanical properties, stability, and biocompatibility
    Liu, Chungeng
    Qiao, Weihua
    Cao, Hong
    Dai, Jinchi
    Li, Fei
    Shi, Jiawei
    Dong, Nianguo
    BIOMATERIALS SCIENCE, 2020, 8 (09) : 2549 - 2563
  • [32] Results of a decellularized porcine heart valve implanted into the juvenile sheep model
    Dohmen, PM
    da Costa, F
    Lopes, SV
    Yoshi, S
    da Souza, FP
    Vilani, R
    da Costa, MB
    Konertz, W
    HEART SURGERY FORUM, 2005, 8 (02): : E100 - E104
  • [33] STRUCTURAL AND MECHANICAL STABILITY OF DECELLULARIZED PORCINE VALVE MATRIX CROSSLINKED WITH CARBODIIMIDE
    Baranska, A.
    Kubin, B.
    Wilczek, P.
    Nozynski, J.
    Helewski, K.
    Wojnicz, R.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (07): : 628 - 628
  • [34] On the bending properties of porcine mitral, tricuspid, aortic, and pulmonary valve leaflets
    Brazile, Bryn
    Wang, Bo
    Wang, Guangjun
    Bertucci, Robbin
    Prabhu, Raj
    Patnaik, Sourav S.
    Ryan Butler, J.
    Claude, Andrew
    Brinkman-Ferguson, Erin
    Williams, Lakiesha N.
    Liao, Jun
    Journal of Long-Term Effects of Medical Implants, 2015, 25 (1-2) : 41 - 53
  • [35] Decellularized porcine pulmonary arteries cross-linked by carbodiimide
    Xu, Xiu-Fang
    Guo, Hai-Ping
    Gong, Da
    Ma, Jin-Hui
    Xu, Zhi-Wei
    Wan, Ju-Yi
    Wang, Zhuo-Guang
    Zhou, Zi-Fan
    Li, Wen-Bin
    Xin, Yi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2013, 6 (07): : 524 - 531
  • [36] The biomechanical effects of fatigue on the porcine bioprosthetic heart valve
    Sacks, Michael S.
    Journal of Long-Term Effects of Medical Implants, 2001, 11 (3-4) : 231 - 247
  • [37] Comparison of biomechanical and structural properties between human aortic and pulmonary valve - Discussion
    Corno, A
    Stradins
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (03) : 639 - 639
  • [38] The Ross procedure: biomechanical properties of the pulmonary artery according to aortic valve phenotype
    Dionne, Pierre Olivier
    Wener, Evan
    Emmott, Alexander
    Cartier, Raymond
    Mongrain, Rosaire
    Leask, Richard
    El-Hamamsy, Ismail
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 23 (03) : 371 - 376
  • [39] Pulmonary valve replacement to treat degenerated right ventricle to pulmonary artery prosthetic conduits and pulmonary valve insufficiency.
    Philipp, B
    Younes, B
    Shakeel, Q
    Damien, B
    Jean, K
    Daniel, S
    CIRCULATION, 2001, 104 (17) : 355 - 355
  • [40] Mechanical properties of decellularized porcine esophagus: Preliminary results
    Lesieur, Romane
    Drochon, Agnes
    Durand, Marlene
    MEDICAL ENGINEERING & PHYSICS, 2025, 137