Effect of STATCOM - ES on Distance Relay Operation in a Series Compensated System

被引:1
|
作者
Rao, H. V. Gururaja [1 ]
Prabhu, Nagesh [2 ]
Mala, R. C. [1 ]
机构
[1] Manipal Inst Technol, Depatrtment Elect & Elect Engn, Manipal 576104, Karnataka, India
[2] NMAMIT, Dept Elect & Elect, Nitte 574110, India
来源
关键词
STATCOM; Energy storage; Emulated Impedance; DQ model; Distance Relay; CONTROLLER; SSSC;
D O I
10.1016/j.protcy.2015.10.088
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Flexible AC transmission systems or FACTS help in a big way to realize a smart grid, which can be used by utilities to reconfigure power flows in real time, maximizing throughput and minimizing losses. It will also facilitate incorporating wind, solar, and other intrinsically intermittent sources of energy into the grid. A static synchronous compensator equipped with energy storage (STATCOM - ES) can provide two degrees of freedom to inject both real and reactive current into the bus. This paper aims at developing the DQ model of a series compensated system which also incorporates a static synchronous compensator with energy storage and analyzing its effect on the operation of distance relay. The emulated conductance and susceptance by STATCOM - ES under various operating conditions is determined and its' effect on impedance at the generator terminals is investigated. Effect of real and reactive power exchange by STATCOM - ES on the measured impedance and operation of distance relay is analyzed. (C) 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:196 / 203
页数:8
相关论文
共 50 条
  • [41] Taylor series based protection starting element for STATCOM compensated transmission line
    Mundra, Prateek
    Arya, Anoop
    Gawre, Suresh K
    Biswal, Sandeep
    Lopes, Felipe V.
    Malik, Om P.
    Electric Power Systems Research, 2022, 204
  • [42] Taylor series based protection starting element for STATCOM compensated transmission line
    Mundra, Prateek
    Arya, Anoop
    Gawre, Suresh K.
    Biswal, Sandeep
    Lopes, Felipe, V
    Malik, Om P.
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 204
  • [43] Adaptive distance relay with combined polarizing quantity based on compensated voltage
    Key Lab. of Power System Protection and Dynamic Security Monitoring and Control, North China Electric Power University, Beijing 102206, China
    不详
    Dianli Xitong Zidonghue, 2007, 19 (38-41+45):
  • [44] Study on distance relay based on pre-fault compensated voltage
    Hu, Yu-Feng
    Liu, Huan-Zhang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2006, 26 (16): : 27 - 32
  • [45] Development of an Intelligent System for Distance Relay Protection with Adaptive Algorithms for Determining the Operation Setpoints
    Akhmedova, Olga
    Soshinov, Anatoliy
    Gazizov, Farit
    Ilyashenko, Svetlana
    ENERGIES, 2021, 14 (04)
  • [46] Synchronized measurement based an adaptive distance relaying scheme for STATCOM compensated transmission line
    Singh, Arvind R.
    Patne, Nita R.
    Kale, Vijay S.
    MEASUREMENT, 2018, 116 : 96 - 105
  • [47] Improvement of longitudinal distance protection for series compensated line
    Zhao, A. (zhaoanguo@sgepri.sgcc.com.cn), 1600, Automation of Electric Power Systems Press (36):
  • [48] Adaptive distance protection for Series Compensated Transmission Lines
    Dutra, R
    Fabiano, L
    Oliveira, W
    Saha, MM
    Lidström, S
    2004 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, 2004, : 581 - 586
  • [49] An Algorithm to Secure the Zone 3 Operation of Distance Relay
    Gawande, Prashant
    Bedekar, Pallavi
    Joshi, Vidyulata
    Dambhare, Sanjay
    PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 975 - 978
  • [50] Improvements in the Operation of a Distance Relay during Resistive Faults
    Cimadevilla, Roberto
    Garcia, Izaskun
    2014 67TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2014, : 132 - 185