Multidetector CT urography: experimental analysis of radiation dose reduction in an animal model

被引:21
|
作者
Kemper, Joern [1 ]
Regier, Marc [1 ]
Bansmann, Paul M. [1 ]
Begemann, Philipp G. C. [1 ]
Stork, Alexander [1 ]
Nagel, Hans Dieter [1 ]
Adam, Gerhard [1 ]
Nolte-Ernsting, Claus [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Ctr Diagnost, Int Radiol, D-20246 Hamburg, Germany
关键词
computed tomography; urography; ureter; Ct; dose reduction; radiation; exposure to personnel and patients;
D O I
10.1007/s00330-006-0565-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the possibility of reducing X-ray exposure during multidetector CT urography (MDCTU) considering image quality using a porcine model. MDCTU was performed in eight healthy pigs. Scanning was conducted using a gradual reduction of the tube current-time product at 120 kV [200-20 mAs (eff.) in ten steps]. Three blinded observers independently evaluated the image data for anatomic detail, subjective image quality, and subjective image noise. Overall image quality was compared to milliampere-second settings and radiation dose. Objective noise measurements were assessed. Noise measurements in patients were also performed to verify the comparabilty of the animal model. Adequate image quality allowing for detailed visualization of the upper urinary tract was obtained when the tube current-time product was decreased to 70 eff. mAs at 120 kV. Image noise did not impair image quality to a relevant degree using these parameters. There was high agreement among the observers (ICC=0.95). In the animal experiments, reduced-dose MDCTU produced good image quality. A maximum current-time product reduction to 70 eff. mAs at 120 kV (CTDIvol=5.3 mGy) proved to be feasible, thereby offering an advantageous dosage reduction. The study provides a basis for the development of reduced-dose MDCTU protocols in humans.
引用
收藏
页码:2318 / 2324
页数:7
相关论文
共 50 条
  • [21] Multidetector CT in children: current concepts and dose reduction strategies
    Nievelstein, Rutger A. J.
    van Dam, Ingrid M.
    van der Molen, Aart J.
    PEDIATRIC RADIOLOGY, 2010, 40 (08) : 1324 - 1344
  • [22] CT urography: clinical indications, limitations and radiation dose: a proposed approach
    Georgiopoulos, I.
    Tsagkatakis, E.
    Nikolakakos, F.
    Neofitou, G.
    Fragioudaki, I.
    Laspas, F.
    Sotirakou, K.
    Karanastasis, D.
    EUROPEAN UROLOGY SUPPLEMENTS, 2009, 8 (08) : 652 - 652
  • [23] Dose reduction in CT urography and vasculature phantom studies using model-based iterative reconstruction
    Page, Leland
    Wei, Wei
    Kundra, Vikas
    Rong, X. John
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 334 - 342
  • [24] Radiation Dose Reduction for Pediatric CT
    Massoumzadeh, P.
    Don, S.
    Whiting, B.
    MEDICAL PHYSICS, 2009, 36 (06) : 2728 - +
  • [25] Radiation Dose Reduction in Thorax CT
    Koc, Gizem Gul
    Kokangul, Ali
    Hanalioglu, Tahir
    CUKUROVA MEDICAL JOURNAL, 2014, 39 (03): : 422 - 427
  • [26] Dose reduction techniques for small animal CT
    Osborne, Dustin
    Stuckey, Alan
    Wall, Jonathan
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [27] CT radiation dose parameters as applied to multidetector-row CT: CTDI and beyond
    Prasad, SR
    Tuli, R
    Wolsey, GT
    Chen, SR
    Dalrymple, NC
    Chintapalli, KN
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 87 - 87
  • [28] Radiation dose from multidetector row CT imaging for acute stroke
    Anisa Mnyusiwalla
    Richard I. Aviv
    Sean P. Symons
    Neuroradiology, 2009, 51 : 635 - 640
  • [29] Radiation dose from multidetector row CT imaging for acute stroke
    Mnyusiwalla, Anisa
    Aviv, Richard I.
    Symons, Sean P.
    NEURORADIOLOGY, 2009, 51 (10) : 635 - 640
  • [30] Dose reduction in oncological staging multidetector CT: effect of iterative reconstruction
    Karpitschka, M.
    Augart, D.
    Becker, H-C
    Reiser, M.
    Graser, A.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1021):