Validated Potentiometric Sensors for Determination of Ramipril in Pharmaceuticals and Biological Fluids using in situ Screen Printed and Carbon Paste Electrodes

被引:4
|
作者
Frag, Eman Yossri [1 ]
Mohamed, Marwa E. [1 ]
Elhassan, Mohamed O. [1 ]
机构
[1] Cairo Univ, Fac Sci, Chem Dept, Giza 12613, Egypt
关键词
ramipril; in situ screen printed and carbon paste electrodes; scanning electron microscopy; energy dispersive X-ray analyzer; pharmaceutical preparations; biological fluids samples; ION-SELECTIVE ELECTRODES; ANTIHISTAMINIC DIPHENHYDRAMINE HYDROCHLORIDE; ANGIOTENSIN-CONVERTING ENZYME; MEMBRANE SENSOR; CONSTRUCTION; INHIBITORS; ENALAPRIL; COMPLEX; PURE;
D O I
10.1134/S1061934820030041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, electroactivity and performance characteristics of in situ screen printed (ISPEs) and carbon paste (ICPEs) electrodes with different types of ion pairing agents were studied in order to evaluate ramipril (RAM) concentrations in pure solutions, pharmaceutical formulations and biological fluids. The surface analysis of the electrodes was carried out using scanning electron microscopy and energy dispersive X-ray analyzer. The electrodes showed linear responses with good Nernstian slopes of 59.6 +/- 0.6 and 58.8 +/- 0.8 mV/decade over the concentration range from 5 x 10(-7) to 1 x 10(-2) M for ISPE and ICPE modified with phosphomolybdic acid (PMA) (electrodes I and III), respectively. At the same time, for ISPE and ICPE modified with phosphotungstic acid (PTA) (electrodes II and IV) slope values of 59.3 +/- 0.9 and 58.3 +/- 0.9 mV/decade, respectively, were obtained. Also, the two types of electrodes modified with PMA and PTA provided response times of about 5 s for ISPEs and 6 s for ICPEs and exhibited lifetimes of 99 and 92 days for electrodes I and II, respectively, and 68 days for the both paste electrodes (III and IV) in the pH range from 2 to 5 for all the proposed electrodes. They showed high thermal stability where the isothermal coefficients were found to be 0.5 x 10(-3) and 1.0 x 10(-3) V/grad for electrodes I and II, respectively, and 0.8 x 10(-3) and 0.9 x 10(-3) V/grad for electrodes III and IV, respectively. Selectivity coefficients of RAM sensors relative to a number of potential interfering materials were investigated. The direct potentiometric determination of ramipril using the prepared sensors gave recoveries between 99.4-99.6, 99.5-99.8, 99.3-99.5 and 99.5-99.6% using electrodes I, II, III and IV, respectively. The developed method was found to be simple, precise and accurate when compared to the reported methods. Method validation parameters were optimized according to IUPAC recommendations.
引用
收藏
页码:384 / 395
页数:12
相关论文
共 50 条
  • [31] Electrochemical determination of bentazone using simple screen-printed carbon electrodes
    Geto, Alemnew
    Noori, Jafar Safaa
    Mortensen, John
    Svendsen, Winnie E.
    Dimaki, Maria
    ENVIRONMENT INTERNATIONAL, 2019, 129 : 400 - 407
  • [32] Chemically modified screen-printed electrodes as efficient potentiometric sensors for cyclobenzaprine hydrochloride determination in pure and pharmaceutical preparations
    Frag, Eman Y.
    Mohamed, Marwa E.
    Abdel Hameed, R. M.
    Mahmoud, Asmaa M.
    APPLIED ORGANOMETALLIC CHEMISTRY, 2020, 34 (03)
  • [33] Amperometric Determination of Dopamine Using Activated Screen-Printed Carbon Electrodes
    Pan, Deng
    Rong, Shengzhong
    Zhang, Guangteng
    Zhang, Yannan
    Zhou, Qiang
    Liu, Fenghai
    Li, Miaojing
    Chang, Dong
    Pan, Hongzhi
    ELECTROCHEMISTRY, 2015, 83 (09) : 725 - 729
  • [34] Potentiometric determination of cetylpyridinium chloride using a new type of screen-printed ion selective electrodes
    Mohamed, Gehad G.
    Ali, Tamer Awad
    El-Shahat, M. F.
    Al-Sabagh, A. M.
    Migahed, M. A.
    Khaled, Elmorsy
    ANALYTICA CHIMICA ACTA, 2010, 673 (01) : 79 - 87
  • [35] A comparative study of tetra-n-butylammonium bromide potentiometric selective screen printed, carbon paste and carbon nanotube modified graphite sensors
    Elashery, Sally E. A.
    Frag, Eman Yossri
    Mousa, Mohamed G.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (04) : 911 - 921
  • [36] A comparative study of tetra-n-butylammonium bromide potentiometric selective screen printed, carbon paste and carbon nanotube modified graphite sensors
    Sally E. A. Elashery
    Eman Yossri Frag
    Mohamed G. Mousa
    Journal of the Iranian Chemical Society, 2020, 17 : 911 - 921
  • [37] Selective potentiometric determination of zolpidem hemitartrate in tablets and biological fluids by using polymeric membrane electrodes
    Kelani, KM
    JOURNAL OF AOAC INTERNATIONAL, 2004, 87 (06) : 1309 - 1318
  • [38] Construction and Validation of New Electrochemical Carbon Nanotubes Sensors for Determination of Acebutolol Hydrochloride in Pharmaceuticals and Biological Fluids
    Alarfaj, Nawal A.
    El-Tohamy, Maha F.
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2014, 61 (08) : 910 - 920
  • [39] ELECTROCHEMICAL STUDIES ON THE APPLICATION OF CARBON PASTE ELECTRODES TO THE DETERMINATION OF OXALIC-ACID IN BIOLOGICAL-FLUIDS
    THRIVIKRAMAN, KV
    KELLER, RW
    WOLFSON, SK
    YAO, SJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1980, 180 (AUG): : 215 - COLL
  • [40] Multi-walled carbon nanotube/poly(glycine) modified carbon paste electrode for the determination of dopamine in biological fluids and pharmaceuticals
    Thomas, Tony
    Mascarenhas, Ronald J.
    Swamy, B. E. Kumara
    Martis, Praveen
    Mekhalif, Zineb
    Sherigara, B. S.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 110 : 458 - 465