Late outcome of percutaneous mitral commissurotomy: Randomized comparison of Inoue versus double-balloon technique

被引:4
|
作者
Lee, Sahmin [1 ]
Kang, Duk-Hyun [1 ]
Kim, Dae-Hee [1 ]
Song, Jong-Min [1 ]
Song, Jae-Kwan [1 ]
Park, Seong-Wook [1 ]
Park, Seung-Jung [1 ]
机构
[1] Univ Ulsan, Coll Med, Div Cardiol, Asan Med Ctr, 88,Olymp Ro 43 Gil, Seoul 05505, South Korea
基金
新加坡国家研究基金会;
关键词
ECHOCARDIOGRAPHIC FOLLOW-UP; PULMONARY-ARTERY PRESSURE; SINGLE-BALLOON; VALVE AREA; VALVULOPLASTY; VALVOTOMY; STENOSIS; SERIES; IMMEDIATE; REGURGITATION;
D O I
10.1016/j.ahj.2017.04.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Late prognosis after successful percutaneous mitral commissurotomy (PMC) is unclear. We compared late results of PMC using Inoue versus double-balloon techniques up to 25 years in a randomized trial. Methods Between 1989 and 1995, 302 patients (77 men, 41 +/- 11 years) with severe mitral stenosis were randomly assigned to undergo PMC using Inoue (n = 152; group I) or double-balloon technique (n = 150; group D). The end points were the composite events of death, mitral surgery, repeat PMC, or deterioration of New York Heart Association (NYHA) class >= 3. Results During median follow-up of 20.7 years (maximum, 25.6), clinical events occurred in 82 (53.9%) patients in group I (37 deaths, 44 mitral surgeries, 9 repeat PMCs, 3 NYHA class >= 3) and in 79 (52.7%) patients in group D (34 deaths, 51 mitral surgeries, 5 repeat PMCs, 4 NYHA class >= 3). Event-free survival rates at 24 years were not significantly different between group I and group D (40.8% and 42.6%, respectively; hazard ratio [HR], 0.88; 95% confidence interval [CI], 0.65-1.20; P =.423). On multivariate analysis, absence of post-PMC commissural mitral regurgitation (MR) (HR, 1.84; 95% CI, 1.28-2.63; P =.001) and immediate post-PMC mitral valve area (MVA) b1.8 cm(2) (HR, 1.53; 95% CI, 1.04-2.25; P =.031) were independently correlated with clinical events after successful PMC. Conclusions The Inoue and double-balloon methods showed similar good clinical outcomes up to 25 years, and the achievement of effective commissurotomy to develop post-PMC commissural MR or immediate post-PMC MVA = 1.8 cm(2) is important in optimizing the late results of PMC.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [21] Long-term results of mitral valvuloplasty: comparison of Inoue- and double-balloon technique
    Bugliani-Pastalka, L
    Bugliani, G
    Suter, T
    Mandinov, L
    Jenni, R
    Hess, OA
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 2000, 130 (35) : 1216 - 1224
  • [22] Comparison of immediate and long-term results of mitral balloon valvotomy with the double-balloon versus Inoue techniques
    Leon, MN
    Harrell, LC
    Simosa, HF
    Mahdi, NA
    Pathan, AZ
    Lopez-Cuellar, J
    Palacios, IF
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (09): : 1356 - 1363
  • [23] PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY - COMPARISON OF DOUBLE AND SINGLE (INOUE) BALLOON TECHNIQUES
    RIHAL, CS
    NISHIMURA, RA
    REEDER, GS
    HOLMES, DR
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 29 (03): : 183 - 190
  • [24] ATRIAL SEPTAL PUNCTURE TECHNIQUE IN PERCUTANEOUS TRANSVENOUS MITRAL COMMISSUROTOMY - MITRAL VALVULOPLASTY USING THE INOUE BALLOON CATHETER TECHNIQUE
    HUNG, JS
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 26 (04): : 275 - 284
  • [25] Long-term clinical and echocardiographic outcome of percutaneous mitral valvuloplasty: Randomized comparison of Inoue and double balloon techniques
    Kang, DH
    Park, SW
    Song, JK
    Kim, HS
    Choil, KJ
    Kim, YH
    Park, SJ
    CIRCULATION, 1998, 98 (17) : 352 - 352
  • [26] PERCUTANEOUS TRANSVENOUS MITRAL COMMISSUROTOMY USING THE INOUE BALLOON - INTERNATIONAL EXPERIENCE
    VAHANIAN, A
    CORMIER, B
    IUNG, B
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, : 8 - 15
  • [27] Clinical and haemodynamic results after percutaneous mitral commissurotomy with the Inoue balloon
    Neumayer, U
    Schmidt, HK
    Fassbender, D
    Mannebach, H
    Bogunovic, N
    Horstkotte, D
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2004, 129 (30) : 1618 - 1621
  • [28] Successful inoue balloon mitral commissurotomy in double-orifice mitral stenosis
    Kim, MH
    Cha, KS
    Kim, JS
    Hung, JS
    Lau, KW
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 49 (02) : 200 - 203
  • [29] RESULTS OF PERCUTANEOUS DOUBLE-BALLOON MITRAL COMMISSUROTOMY IN ONE MEDICAL-CENTER IN TUNISIA
    BENFARHAT, M
    BETBOUT, F
    GAMRA, H
    MAATOUK, F
    AYARI, M
    CHERIF, A
    JARRAR, M
    BOUSSADIA, H
    HAMMAMI, S
    CHAHBANI, I
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (17): : 1266 - 1270
  • [30] MONO-BALLOON VERSUS DOUBLE-BALLOON TECHNIQUE FOR COMMISSURAL SPLITTING AFTER PERCUTANEOUS MITRAL VALVOTOMY
    FERNANDEZORTIZ, A
    MACAYA, C
    ALFONSO, F
    HERNANDEZ, R
    INIGUEZ, A
    GOICOLEA, J
    BANUELOS, C
    ZARCO, P
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (12): : 1100 - 1101