Acetabular Component Positioning Using the Transverse Acetabular Ligament Can You Find It and Does It Help?

被引:48
|
作者
Epstein, Noah J. [1 ,2 ]
Woolson, Steven T. [1 ,2 ]
Giori, Nicholas J. [1 ,2 ]
机构
[1] Stanford Univ, Dept Orthopaed Surg, Sch Med, Stanford, CA 94305 USA
[2] Palo Alto Vet Adm Hosp, Palo Alto, CA 94304 USA
关键词
TOTAL HIP-ARTHROPLASTY; POLYETHYLENE WEAR; ORIENTATION; DISLOCATIONS; REPLACEMENT; CUP;
D O I
10.1007/s11999-010-1523-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Several studies have reported that the transverse acetabular ligament (TAL) can be used to orient the acetabular component during total hip arthroplasty and that it can be identified in nearly all patients. Questions/purposes We attempted to determine how often the TAL could be identified during primary THA and its accuracy as a guide for acetabular component positioning. Methods In a prospective series of 63 patients (64 hips) undergoing primary THA, two surgeons attempted to identify the TAL and, if it was found, to use it for acetabular component orientation. Patients in whom the TAL was identified served as the study group and the ligament was used for cup orientation in those patients; the remaining patients in whom the ligament could not be identified served as a control group and had free-hand cup positioning. Anteversion was determined by radiographic measurement from true lateral views. Results The TAL was identified in only 30 hips (47%) and was more likely to be found in patients who did not have inferior acetabular osteophytes. Acetabular position was not improved using this ligament for reference. Conclusions The TAL could not be routinely identified at surgery and when used for cup orientation it was no more accurate for cup positioning than free-hand technique.
引用
收藏
页码:412 / 416
页数:5
相关论文
共 50 条
  • [21] Periprosthetic acetabular bone loss using a constrained acetabular component
    Hiroshi Ito
    Takeo Matsuno
    Archives of Orthopaedic and Trauma Surgery, 2004, 124 : 137 - 139
  • [22] Does robotic assisted technology improve the accuracy of acetabular component positioning in patients with DDH?
    Zhou, Yixin
    Shao, Hongyi
    Huang, Yong
    Deng, Wang
    Yang, Dejin
    Bian, Tao
    JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (02)
  • [23] Fluoroscopically Guided Acetabular Component Positioning: Does It Reduce the Risk of Malpositioning in Obese Patients?
    Gosthe, Raul G.
    Suarez, Juan C.
    McNamara, Colin A.
    Calvo, Cecilia
    Patel, Preetesh D.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (10): : 3052 - 3055
  • [24] Precision of Robotic Guided Instrumentation for Acetabular Component Positioning
    Kanawade, Vaibhav
    Dorr, Lawrence D.
    Banks, Scott A.
    Zhang, Zenan
    Wan, Zhinian
    JOURNAL OF ARTHROPLASTY, 2015, 30 (03): : 392 - 397
  • [25] The Importance of Proper Acetabular Component Positioning and the Challenges to Achieving It
    Schmalzried, Thomas P.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2009, 19 (03) : 132 - 136
  • [26] Quantifying the Relationship Between the Transverse Acetabular Ligament and the Radiographic Teardrop
    Harris, Matthew J.
    Tam, Jason
    Fineberg, Steven J.
    Lucas, Paul A.
    Zelicof, Steven B.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (01): : 296 - 299
  • [27] Orientation of Transverse Acetabular Ligament With Reference to Anterior Pelvic Plane
    Deep, Kamal
    Prabhakara, Anjan
    Mohan, Diwakar
    Mahajan, Vivek
    Sameer, Mohamed
    ARTHROPLASTY TODAY, 2021, 7 : 1 - 6
  • [28] Augmentation of the transverse acetabular ligament in canine caudoventral hip luxation
    Venzin, C.
    Montavon, P. M.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2007, 20 (04) : 320 - 323
  • [29] The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement - A preliminary study of 1000 cases investigating postoperative stability
    Archbold, H. A. P.
    Mockford, B.
    Molloy, D.
    McConway, J.
    Ogonda, L.
    Beverland, D.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07): : 883 - 886
  • [30] Limb length restoration during total hip arthroplasty: Use of a caliper to control femoral component insertion and accurate acetabular placement relative to the transverse acetabular ligament
    Archbold, HAP
    Mohammed, M
    O'Brien, S
    Molloy, D
    McConway, J
    Beverland, DE
    HIP INTERNATIONAL, 2006, 16 (01) : 33 - 38