Three-dimensional reconstructions of carotid bifurcation from CT images: Evaluation of different rendering methods

被引:0
|
作者
Tarjan, Z [1 ]
Mucelli, FP [1 ]
Frezza, F [1 ]
Mucelli, RP [1 ]
机构
[1] UNIV HOSP TRIESTE,OSPED CATTINARA,DEPT RADIOL,I-34149 TRIESTE,ITALY
关键词
3D-CTA; carotid arteries; CT comparative studies; CT image processing;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional computed tomographic angiography (3D-CTA) and digital subtraction angiography of the cervical carotid artery were preformed bilaterally in 15 patients with suspected stenoses. A new semi-automatic segmentation and new rendering methods were used. The degree of stenosis of internal carotid arterics, as determined both by axial slices and 3D images (surface, integral, maximum-intensity-projection, and raysum-rendered images), was compared qualitatively and quantitatively to angiographic findings. In correlation to angiography, the accuracy in determining the stenosis classification of internal carotid arteries was of 97% for axial slices and 59-90% for 3D images, respectively. Raysum (pseudoradiograph) rendering was found to be the most reliable rendering method and gave the most similar results to angiography. The accuracy of all rendering methods was improved by applying calcification removing algorithm, with a statistically significant difference between surface rendering without plaque removal and raysum rendering using the removing algorithm.
引用
收藏
页码:326 / 333
页数:8
相关论文
共 50 条
  • [21] Correction methods for three-dimensional reconstructions from confocal images:: I.: tissue shrinking and axial scaling
    Bucher, D
    Scholz, M
    Stetter, M
    Obermayer, K
    Pflüger, HJ
    JOURNAL OF NEUROSCIENCE METHODS, 2000, 100 (1-2) : 135 - 143
  • [22] Methods for displaying three-dimensional images
    Son, JY
    Javidi, B
    Kwack, KD
    PROCEEDINGS OF THE IEEE, 2006, 94 (03) : 502 - 523
  • [23] Foot measurements from three-dimensional scans: A comparison and evaluation of different methods
    Witana, Channa P.
    Xiong, Shuping
    Zhao, Jianhui
    Goonetilleke, Ravindra S.
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2006, 36 (09) : 789 - 807
  • [24] Advantages and Pitfalls of Three-Dimensional Ultrasound Imaging of Carotid Bifurcation
    Vicenzini, E.
    Galloni, L.
    Ricciardi, M. C.
    Pro, S.
    Sirimarco, G.
    Pulitano, P.
    Mecarelli, O.
    Di Piero, V.
    Lenzi, G. L.
    EUROPEAN NEUROLOGY, 2011, 65 (06) : 309 - 316
  • [25] Quantitative measures of carotid disease from three-dimensional ultrasound images
    Barratt, Dean C.
    Ariff, Ben B.
    Davies, Alun H.
    Hughes, Alun D.
    Thom, Simon A.McG.
    Humphries, Keith N.
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):
  • [26] Gastric lesions: Evaluation with three-dimensional images using helical CT
    Lee, DH
    Ko, YT
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (03) : 787 - 789
  • [27] Variance in three-dimensional reconstructions from projections
    Penczek, PA
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 749 - 752
  • [28] Evaluation of carotid artery stenosis with three-dimensional CT angiography and surgical revascularization
    Ohtaki, M
    Tanabe, S
    Uede, T
    Hashi, K
    NEUROLOGICAL SURGERY, 1996, 24 (11): : 995 - 1002
  • [29] Three-dimensional fetal cephalometry: An evaluation of the reliability of cephalometric measurements based on three-dimensional CT reconstructions and on dry skulls of sheep fetuses
    Papadopoulos, MA
    Jannowitz, C
    Boettcher, P
    Henke, J
    Stolla, R
    Zeilhofer, HF
    Kovacs, L
    Erhardt, W
    Biemer, E
    Papadopulos, NA
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2005, 33 (04) : 229 - 237
  • [30] Evaluation of Spherical Parameterization Methods for Three-dimensional Reconstruction of Medical images
    Wu, Xing Hui
    Hao, Zhi Xiu
    MACHINE DESIGN AND MANUFACTURING ENGINEERING II, PTS 1 AND 2, 2013, 365-366 : 1342 - 1349