Feedback compensation method for angular displacement measurement based on a Fabry-Perot interferometer

被引:0
|
作者
Zhang Caini [1 ]
Zhang Xiaopeng [1 ]
机构
[1] Zhejiang Univ, Hangzhou 310027, Peoples R China
关键词
Feedback compensation; angular displacement measurement; Fabry-Perot plate; INTERNAL-REFLECTION;
D O I
10.1117/12.866937
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, we describe a new method for wide range and high-precision angular displacement measurement. In this method, the system real-time detects the testing object rotation, obtains the wide range angular displacement through accumulating its micro angular displacement. By adjusting the reflector, the beams reflected from the testing object normal incidence to the FP plate, before it is rotated. When the testing object is rotated, the system real-time gives the testing object micro angular displacement and the rotated angle of the Fabry-Perot (FP) plate. The testing object micro angular displacement is used for accumulating. The FP plate is real-time rotated under the control of the feedback system to compensate the initial angle's loss of incidence on the FP plate, and makes the beams reflected from the testing object normal incidence to the FP plate all the time. Each measurement accuracy of 10(-8) is abstained by use of the sinusoidal phase-modulating interferometry([1, 2]). So that, the wide range and high-precision angular displacement measurement is obtained.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] MULTIPLEX FABRY-PEROT INTERFEROMETER
    HIRSCHBERG, JG
    FRIED, WI
    HAZELTON, L
    WOUTERS, A
    APPLIED OPTICS, 1971, 10 (08) : 1979 - +
  • [42] A nanostructured Fabry-Perot interferometer
    Zhang, Tianhua
    Gong, Zhongcheng
    Giorno, Rebecca
    Que, Long
    OPTICS EXPRESS, 2010, 18 (19): : 20282 - 20288
  • [43] Anticaustics in a Fabry-Perot interferometer
    Sanchez-Soto, Luis L.
    Monzon, Juan J.
    Leuchs, Gerd
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2022, 39 (12) : C74 - C78
  • [44] Tuned Fabry-Perot Interferometer
    Walczak, A
    Nowinowski-Kruszelnicki, E
    Jaroszewicz, LR
    Marciniak, P
    SEVENTH INTERNATIONAL SYMPOSIUM ON LASER METROLOGY APPLIED TO SCIENCE, INDUSTRY, AND EVERYDAY LIFE, PTS 1 AND 2, 2002, 4900 : 901 - 907
  • [45] AURAS FABRY-PEROT INTERFEROMETER
    SMITH, MG
    SKY AND TELESCOPE, 1973, 45 (04): : 208 - 211
  • [46] A signal interpolation method for Fabry-Perot interferometer utilized in mechanical vibration measurement
    Shyu, Lih-Horng
    Wang, Yung-Cheng
    Chang, Chung-Ping
    Shih, Hung-Ta
    Manske, Eberhard
    MEASUREMENT, 2016, 92 : 83 - 88
  • [47] Grating angular displacement transducer using a Fabry-Perot structure
    Li, ZQ
    Qiang, XF
    Wu, ZX
    Fan, LN
    OPTICAL SENSING, IMAGING, AND MANIPULATION FOR BIOLOGICAL AND BIOMEDICAL APPLICATIONS, 2000, 4082 : 315 - 320
  • [48] Wide-Range Displacement Sensor Based on Fiber-Optic Fabry-Perot Interferometer for Subnanometer Measurement
    Zhou, Xinlei
    Yu, Qingxu
    IEEE SENSORS JOURNAL, 2011, 11 (07) : 1602 - 1606
  • [49] Vibration-displacement measurements based on a polarimetric extrinsic fibre Fabry-Perot interferometer
    Seat, HC
    Ouisse, E
    Morteau, E
    Métivier, V
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (06) : 710 - 716
  • [50] Real-time displacement reconstruction by an orthogonal Fabry-Perot interferometer
    Liang, Hongwei
    Liu, Shiwei
    Chen, Sihan
    Huang, Zhen
    Jiang, Chunlei
    Chen, Peng
    Kan, Lingling
    APPLIED OPTICS, 2021, 60 (24) : 7064 - 7068