A Custom-Design Data Logger Core for Physiological Signal Recording

被引:6
|
作者
Rieger, Robert [1 ]
Huang, Yan-Ru [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Elect Engn, Kaohsiung 80424, Taiwan
关键词
Application-specific integrated circuit (ASIC); biomedical data acquisition; data logger; memory controller; MultiMediaCards (MMCs); programmable logic device (PLD);
D O I
10.1109/TIM.2010.2051609
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Large data volumes are generated in physiological signal loggers so that the available memory becomes a limiting factor, particularly in small-size wearable applications. This paper demonstrates the practicality of using a programmable logic device as controller for MultiMediaCard memory for implementing a data logger, which can ultimately be realized as a fully integrated circuit. A minimum configuration in terms of complexity, cost, and size is sought using a minimal subset of the serial peripheral interface protocol and minimum overhead. The data bus frequency is linked to the converter clock, which ensures continuous data streaming with little implementation effort. The hardware realization of the controller in a 0.18-mu m CMOS process occupies 0.014 mm(2). The measured results confirm the performance of the logger using the electrocardiogram as a representative signal.
引用
收藏
页码:532 / 538
页数:7
相关论文
共 50 条
  • [31] Field trials of a new physiological data logger in active fishes
    Clark, Timothy Darren
    Frappell, Peter B.
    Taylor, Brian
    Farrell, Anthony
    Hinch, Scott
    Seymour, Roger S.
    FASEB JOURNAL, 2008, 22
  • [32] DATA LOGGER. AN APPLICATION FOR RECORDING GPS DATA AND EXPORTING THEM TO GIS APPLICATIONS
    Ioannou, K. S.
    Lefakis, P. D.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2010, 11 (02): : 718 - 732
  • [33] PAIN RECORDING WITH A PORTABLE DATA-LOGGER IN PEPTIC-ULCER
    GUSTAVSSON, S
    NYREN, O
    HEDIN, B
    GASTROENTEROLOGY, 1985, 88 (05) : 1408 - 1408
  • [34] AN INTEGRATED PHYSIOLOGICAL SIGNAL MEASUREMENT AND RECORDING CHAIR
    Chang, Hsien-Tsung
    Chung, Chyan-Goei
    Chen, Ming-Wei
    FIRST INTERNATIONAL SYMPOSIUM ON BIOENGINEERING (ISOB 2011), PROCEEDINGS, 2011, : 196 - 204
  • [35] Wearable light data logger for studying physiological and psychological effects of light data
    Rhudy, Matthew B.
    Greenauer, Nathan
    Mello, Catherine
    HARDWAREX, 2020, 8
  • [36] Comprehensive Methodology for Custom-Design and Manufacture of Soft-Tissue Prosthesis: Orbital Case-Study
    Couto, Mafalda
    Machado, Margarida
    Reis, Ana
    Neto, Rui
    Alves, Jorge L.
    2017 IEEE 5TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2017,
  • [37] ALL SOLID-STATE DATA LOGGER FOR RECORDING SLOW SEA OSCILLATIONS
    OTTONELLO, P
    PAPA, L
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1980, 13 (03): : 287 - 288
  • [38] Design of One-lead ECG Data Logger
    Babusiak, Branko
    Gala, Michal
    Barabas, Jan
    2015 38TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2015,
  • [39] A DIGITAL FORMAT FOR RECORDING PHYSIOLOGICAL DATA
    WILSON, SD
    ADAMS, M
    HALPERN, A
    BEAZELL, J
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (08) : 550 - 551
  • [40] Design of the Data Logger with IEC Standard for PV System
    Rewthong, Orrawan
    Boonbumroong, Usa
    Mamee, Thatree
    Eamthanakul, Busarin
    Luewarasirikul, Narun
    Tabkit, Nantavat
    2019 8TH INTERNATIONAL CONFERENCE ON INFORMATICS, ENVIRONMENT, ENERGY AND APPLICATIONS (IAEA 2019), 2019, : 234 - 237